High-performance liquid chromatography column-packing equipment

Apparatus Use a suitable high-performance liquid chromatography system (see Chromatography, Appendix IIA) equipped with a dual wavelength detector system such that the effluent can be monitored serially at 254 nm and 325 to 385 nm (wide-band pass). Use a 1-m x 2.1-mm (id) column, or equivalent, packed with a strong anion-exchange resin (Dupont No. 830950405, or equivalent). [Pg.884]

Sugars. The high performance liquid chromatography (HPLC) method described by Hunt et al. (8) was used to determine the sugars in the kiwifruit and nectars with some modifications (21). A Waters Association Chromatograph equipped with a Model 6000-A solvent delivery system, a Model R401 refractometer detector, a D6K universal injector column was a 30 cm x 4 mm i.d. stainless steel tube packed with u-bondapak-carbohydrate (Waters Associates). The precolumn was packed with CO-PELL PAC (Whatman). The eluent was acetonitril and distilled water (85/15, v/v). [Pg.308]

High-performance liquid chromatography (HPLC) uses high pressure to force eluent through a closed column packed with micrometer-size particles that provide exquisite separations. The analytical HPLC equipment in Figure 22-14 uses columns... [Pg.490]

High performance liquid chromatography was performed with a high pressure liquid chromatography apparatus equipped with a U.V. detector (280 nm). The U.V. monitor has an 8 pi flow cell. The chromatographic column was a 20 cm x 2.1 mm (internal diameter) pre-packed stainless-steel Micro-Pack" column (Varian, Palo Alto, Calif.,... [Pg.304]

Procedure (See Chromatography, Appendix IIA.) Use a high-performance liquid chromatograph capable of separating acesulfame potassium and 4-hydroxybenzoic acid ethyl ester with a resolution of 2. Use a chromatograph equipped with a UV or diode array (227 nm) detector and a 25-cm x 4.6-mm (id) stainless steel column, or equivalent, packed with 3 to 5 p,m of reversed phase C18 silica gel, or equivalent. The elution is isocratic. Use a 40 60 (v/v) solution of acetoni-trile 0.01 MlL tetrabutyl ammonium hydrogen sulfate (TBAHS) in water as the mobile phase, with a flow rate of about 1 mL/min. [Pg.10]

Chromatographic System (See Chromatography, Appendix IIA.) Use a suitable high-performance liquid chromatograph equipped with a detector measuring at 210 nm and a 250- x 4.6-mm (id) column packed with octadecyl silanized silica (10-p.m Partisil ODS-3, or equivalent), and operated under isocratic conditions at 40°. The flow rate of the Mobile Phase is about 2 mL/min. [Pg.38]

Procedure (See Chromatography, Appendix BA.) Use a suitable high-performance liquid chromatograph equipped with differential refractometer, autosampler injection unit, mobile-phase degasser, column heating block or oven, and a computing integrator. The column is Lichrosorb RP-18 250-mm x 4.5 mm (id) (GL Science, Inc., or equivalent) and YMC-Pack ODA-A A-303 250-mm x 4.5 mm (id) (YMC Company, Ltd., or equivalent) connected in a series, or equivalent, maintained at 50°. Use 80 20 acetone acetonitrile as the eluent, at a flow rate of 2 mL/min. [Pg.51]

Procedure (See Chromatography, Appendix IIA.) Use a high-performance liquid chromatograph equipped with an ultraviolet detector that measures absorption at 254 nm and a 25- to 30-cm x 4-mm (id) stainless-steel column, or equivalent, packed with octadecyl silane chemically bonded to porous silica or ceramic microparticles 5 to 10 pun in diameter, or equivalent. Maintain the mobile phase at a pressure and flow rate capable of giving the required resolution (see below). Inject a volume, up to 25 pL, of the System Suitability Solution in a similar manner. Calculate the resolution, R (>3.6), between calcium formyltetrahydrofolate and Folic Acid by the equation... [Pg.180]

Procedure Use a high-performance liquid chromatograph (see Chromatography, Appendix IIA) equipped with an ultraviolet detector that measures at 254 nm. Under typical conditions, the instrument contains a 300- x 4-mm (id) column packed with 10-p.m octadecylsilanized silica (jxBon-dapak C 18, or equivalent). Set the flow rate at about... [Pg.472]


See other pages where High-performance liquid chromatography column-packing equipment is mentioned: [Pg.228]    [Pg.865]    [Pg.89]    [Pg.2]    [Pg.273]    [Pg.89]    [Pg.813]    [Pg.97]    [Pg.235]    [Pg.358]    [Pg.264]    [Pg.259]    [Pg.34]    [Pg.416]    [Pg.286]    [Pg.402]    [Pg.17]    [Pg.207]    [Pg.384]    [Pg.2]    [Pg.63]    [Pg.153]    [Pg.229]    [Pg.267]    [Pg.270]    [Pg.443]    [Pg.201]    [Pg.9]    [Pg.18]    [Pg.24]    [Pg.22]    [Pg.23]    [Pg.311]    [Pg.23]    [Pg.25]    [Pg.232]    [Pg.27]   
See also in sourсe #XX -- [ Pg.21 ]




SEARCH



Chromatography column packing

Chromatography column performance

Chromatography packed

Chromatography packing

Column chromatography

Column chromatography columns

Column performance

Column-packing equipment

Equipment packed columns

Equipment packing

Equipment performance

High columns

High performance columns

High performance liquid chromatography column packings

High-performance liquid chromatography equipment

High-performance liquid column packing

Liquid chromatography (packed columns)

Liquid chromatography columns

Liquid chromatography equipment

Liquid chromatography packing

Liquid column

Liquid packed columns

Packed columns

Packed columns, packing