Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Entry ports

On the evidence given here, the tablet conditioner seemed to work well, but the geometrical positions associated with the means (1.249, 1.775) differ from those with the means (1.069. .. 1.107) indeed, five of these positions were near the entry port of the controlled-humidity airstream, and the other two were situated in comers somewhat protected from the air currents. The 1.159 group marks the boundary of the acceptable region. [Pg.193]

The equipment used in this application included two Waters M-45 pumps, a Waters 481 UV detector with microbore cell, an air-actuated Rheodyne 7413 injection valve with a 1-pl injection loop, an air-actuated Valeo four-port sampling valve (A2CI4UW2) with no groove in the injection entry ports, an air-actuated Valeo three-port switching valve (AC3W), and a Digital Equipment LSI-11/23 microcomputer. The LC system was located in a purged cabinet suitable for use in Class I, division 2 areas. The cabinet was in a heated room about 40 feet from the reactor column. The two Valeo valves were mounted next to the reactor column, while the microcomputer was located in the control room. [Pg.83]

Various hollow-cone simplex atomizers (Fig. 2.1) have been developed for combustion applications, differing from each other mainly in the way that swirl is imparted to the issuing liquid jet. In these atomizers, swirl chambers may have conical slots, helical slots (or vanes), or tangential slots (or drilled holes). Using thin, removable swirl plates to cut or stamp the swirl chamber entry ports leads to economies of the atomization systems if spray uniformity is not a primary concern. Large simplex atomizers have found applications in utility boilers and industrial furnaces. Oil flow rates can be as high as 67 kg/min. [Pg.30]

The sample-transport mechanism is the physical link between the units for the basic operations and it moves the sample cups to the entry ports. The sample identification system ensures that samples are available to the appropriate unit at the right time. The mechanism functions hke a railway system it receives a command to move a cup containing a standard volume of sample from one place to another and then waits for the next instruction, which may require transport of the next sample cup or of the same sample to a different module. [Pg.42]

A dry-bag is a bag, usually about 0.5 x 1 m, made of a transparent, inert and tough film or sheet which has an easily sealable entry port for inserting apparatus and several ports for admitting purging gas, electrical leads, etc., and at least two gloves so that operations can be done inside it. [Pg.6]

Primary zone size is important with regard to efficiency and limits also. Within practical limits, a larger primary zone cross-sectional area will provide the best performance 138). Possible reasons arc lower velocities, less wall impingement by fuel, larger zone of low velocity, and less wall quenching of chemical reactions. The best axial distribution of open area of a combustor will depend on required operating conditions, the pressure loss characteristics, and the shape of the air entry ports. It will also depend on fuel-injection and fuel-volatility characteristics, as these factors will affect the amount of vapor fuel present at any location. If proper burning environment is to be obtained, these factors must be matched, and compromises in performance must be expected. [Pg.266]

A typical design of an automatic self-cleaning filter allows pressurized dirty water to first enter an upper chamber via a flanged entry port, where the water is filtered through a coarse screen. From here the water is then directed through a stainless steel fine mesh screen located in a lower chamber and out through a flanged exit port. [Pg.61]

A lateral percolation filter was fabricated on quartz (see Figure 8.2). The filter elements, which were located near the entry port of a channel, had 1.5 im channel width and 10 im depth. They were anisotropically etched with an aspect ratio greater than 30 1 [828], In contrast to the usual axial slit filter, in which the filter area is dictated by the channel area, the fluid flow in the lateral percolation filter... [Pg.251]

A plasma spray can therefore be used to apply sintered coatings to substrates which would normally be adversely affected by the sintering temperature of the coating. However, the powders carried by the plasma are exposed to greater thermal stress than the substrate, and some experimenting with specific powders is usually necessary to define the best application conditions. Where molybdenum disulphide in a metal, resin or ceramic binder is applied by this technique, the optimum conditions will usually be different for the two materials. This difficulty has been overcome by the use of two separate entry ports into the nozzle for the two components. The use of this technique has even been applied to molybdenum disulphide in a polyethylene binder. [Pg.196]

This system was developed in an attempt to eliminate some of the problems associated with nest sieving and to automate the process [110,111]. A hexagonal sieving chamber is supported on discs and rotated. A steady stream of powder is fed to the entry port and, as the sieve rotates, the powder gently moves across the surface. As the sieve rotates further, the powder is picked up by a vane and dumped out of the other side of the... [Pg.243]

ZSM-5 incorporates two systems of intersecting channels lying along the a and b crystal axes (22) the straight channels have elliptical apertures with cross-sections of 0.51 X 0.55 nm, and the sinusoidal channels have nearly circular apertures with cross-sections of 0.53 x 0.56 nm. At the channel intersections there are cages about 1 nm in diameter with 0.6-nm diameter entry ports (Fig. 3). [Pg.513]

Attach three short pieces of silicon tubing with female stericonnectors and blanking plugs, i.e. for base and medium addition, with one spare entry port. Place a Universal bottle on the sampling plot. [Pg.273]


See other pages where Entry ports is mentioned: [Pg.1684]    [Pg.1826]    [Pg.903]    [Pg.132]    [Pg.144]    [Pg.155]    [Pg.262]    [Pg.44]    [Pg.263]    [Pg.262]    [Pg.679]    [Pg.97]    [Pg.660]    [Pg.54]    [Pg.562]    [Pg.133]    [Pg.1]    [Pg.573]    [Pg.574]    [Pg.232]    [Pg.246]    [Pg.244]    [Pg.418]    [Pg.448]    [Pg.708]    [Pg.138]    [Pg.35]    [Pg.59]    [Pg.59]    [Pg.1505]    [Pg.1585]    [Pg.660]    [Pg.717]    [Pg.660]    [Pg.325]    [Pg.479]    [Pg.660]    [Pg.340]   
See also in sourсe #XX -- [ Pg.222 ]




SEARCH



Ports

© 2024 chempedia.info