Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Screening electrodes

For the detection different electrode supports and a great variety of immobilization procedures have been used. Gold electrodes, screen-printed electrodes and carbon materials (such as graphite and glassy carbon) have been frequently used. The sensing phase is constructed onto the surface of the electrode by means... [Pg.2058]

Insert a drill bit through the hole in the pipe wall to make a hole in the positive electrode screen... [Pg.105]

Adsorption of Escherichia coli cells onto acetylcellulose membranes and attachment of the membrane to a Teflon membrane of an oxygen electrode Screening of mutagens [62]... [Pg.219]

Both membranes are suitably framed to separate them from the cathode and the anode. Plastic electrode screens prevent the membranes from touching the electrodes. Flows through the cell compartments are from the bottom of the cell to the top, which provide good... [Pg.108]

Electrolyte enters from the side near the bottom of two rigid, plastic end blocks supporting the stack and exists from the diagonal top sides. The two electrolyte compartments are fed independently. When running the cell the center (electrolyte) compartment is overpressured by one psi, thus forcing the membrane to lie against the electrode screening. [Pg.109]

The reverse sequence was used on the other side of the anode to complete a symmetrical cell pair. Thus, each side of the anode was divided into three compartments separated by the ion-selective membranes. Thirteen tie bolts kept the stack tightly sealed. One wooden peg through the stack top kept the stack components from sliding and disaligning the assembly. Effective area of the membranes was one square foot. The membrane frames separated the membranes from the electrodes. The plastic electrode screen prevented the membranes from touching the electrodes. The cell construction or stack assembly is illustrated in Figure 11.2. Figure 11.1 also shows a side view of the cathode. [Pg.114]

Spending amperometric electrodes ( screen mode , Sect. 3.2), and the large electrodes are not contaminated as easily as the smaller disc electrodes. On the other hand, porous electrodes cannot be replaced. They are cleaned by flushing the cell with a nitric acid solution and organic solvents. One should also take care in connecting coulometric cells after spectroscopic detectors, as the backpressure resulting from porous electrodes may harm optical flow cells. [Pg.97]

Kroger, S. Turner, A.P.F. Solvent-Resistant Carbon Electrodes Screen Printed onto Plastic for Use in Biosensors. Anal. Chim. Acta 1997, 347 9-18. [Pg.700]

One configuration that can be used to ampero-metrically detect the peroxide produced from the oxidation of sarcosine is a Pt working electrode, a Ag/AgCl reference electrode, and a carbon counter electrode screen-printed onto a polyester sheet. The enzymes can be immobilized on the working... [Pg.742]

For a given situation, such as a controlled laboratory environment, these factors may be more constant and more easily measured. In the laboratory, electrical noise can be minimized and a higher sensitivity achieved with short leads, special reference electrodes, and clean solutions. In the real world of operating plant conditions, damage of electrodes, screening of the electrodes by oil or other nonconductive... [Pg.190]

Moreover, the reference electrode tip, usually the orifice of the Haber-Luggin capillary, should be positioned close to the working electrode. Insulating objects in the electrolyte, however, mean distortions of the current distribution and, thus, local potential changes. Therefore, the capillary should not come too close to the electrode (screening effect, [10, 11]). A more distant position, however, means a larger electrolyte... [Pg.1144]

In order to screen mutants with improved direct electron transfer, it is necessary to use an electrochemical screening system. Currently, only a few electrochemical screening methods were described in literature such as the system developed by the Bartlett group used to screen NADH electro-oxidation. This system uses a multichannel potentiostat with sixty electrodes to screen zinc(n) or ruthenium(ii) complexes bearing the redox phenidione as a mediator for NADH oxidation. It allows the complete evaluation of the electrochemical kinetic constants of the mediators and the immobilization procedure. Unfortunately, this system could only be used with a single electrolyte solution for all the electrodes (e.g., when a single reaction condition or enzyme is assayed), and it requires mL-scale reaction volumes. Recently, another system was described which makes it possible to screen bioelectrocatalytic reactions on 96 independent electrodes screen-printed onto a printed-circuit-board. It showed the possibility to screen direct or mediated electron transfer between oxidoreductases and electrode by intermittent pulse amperometry at the pL-scale (Fig. 6). The direct electron transfer assay was validated with laccase and unmodified electrodes.As an example of the mediated electron transfer assay, the 96 carbon electrodes were modified by phenazines to sereen libraries of a formate dehydrogenase obtained by directed evolution. ... [Pg.117]

Centi, S., Stoica, A.I., Laschi, S. and Mascini, M. (2010) Development of an electrochemical immunoassay based on the use of an eight-electrodes screen-printed array coupled with magnetic beads for the detection of antimicrobial sulfonamides in honey Electroanalysis, 22, 1881-1888. [Pg.285]

The dust which has already settled on the electrode screens its surface and makes it less efficient in purifying a gas flow [377]. First of all the attached dust may be removed mechanically by blasting the dust-laden surface, scrubbing it, subjecting it to vibrations or blows, and also by washing it with water. [Pg.301]

Figure 2. Gas sensor consisting of doped polypyrrole electrochemically polymerised on to interdlgltated gold electrodes screen-printed on an alumina substrate. Figure 2. Gas sensor consisting of doped polypyrrole electrochemically polymerised on to interdlgltated gold electrodes screen-printed on an alumina substrate.
Electroluminescent lamps Transparent electrode Screen printing PEDOT PSS Established... [Pg.266]


See other pages where Screening electrodes is mentioned: [Pg.650]    [Pg.75]    [Pg.1790]    [Pg.17]    [Pg.344]    [Pg.265]    [Pg.190]    [Pg.325]    [Pg.43]    [Pg.206]    [Pg.264]   
See also in sourсe #XX -- [ Pg.79 ]




SEARCH



Chemical methods screen-printed electrodes

Conductivity screen-printed carbon electrodes

Enzymatic Genosensors on Streptavidin-Modified Screen-Printed Carbon Electrode

Fabrications screen-printed electrodes

Flow injection analysis screen-printed electrodes

Genosensors on Screen-Printed Electrodes

Gold nanostructuration of screen-printed carbon electrodes

Gold screen-printed electrodes

Heavy metals screen-printed electrodes

Planar screen-printed electrodes

Repeatability screen-printed electrodes

Reproducibility screen-printed electrodes

Screen printing electrodes

Screen-Printed Electrodes (SPE)

Screen-printed carbon electrode

Screen-printed carbon electrodes SPCEs)

Screen-printed carbon electrodes electroanalysis

Screen-printed electrodes

Screen-printed electrodes (SPEs

Screen-printed electrodes (SPEs applications

Screen-printed electrodes (SPEs reproducibility

Screen-printed electrodes (SPEs sensitivity

Screen-printed functionalized electrodes

Screening methods screen-printed electrodes

Sensitivity screen-printed electrodes

Surface waters screen-printed electrodes

Types of Screen-Printed Electrodes

© 2024 chempedia.info