Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Detector chromatographic methods

Acrolein is produced according to the specifications in Table 3. Acetaldehyde and acetone are the principal carbonyl impurities in freshly distilled acrolein. Acrolein dimer accumulates at 0.50% in 30 days at 25°C. Analysis by two gas chromatographic methods with thermal conductivity detectors can determine all significant impurities in acrolein. The analysis with Porapak Q, 175—300 p.m (50—80 mesh), programmed from 60 to 250°C at 10°C/min, does not separate acetone, propionaldehyde, and propylene oxide from acrolein. These separations are made with 20% Tergitol E-35 on 250—350 p.m (45—60 mesh) Chromosorb W, kept at 40°C until acrolein elutes and then programmed rapidly to 190°C to elute the remaining components. [Pg.124]

For selective estimation of phenols pollution of environment such chromatographic methods as gas chromatography with flame-ionization detector (ISO method 8165) and high performance liquid chromatography with UV-detector (EPA method 625) is recommended. For determination of phenol, cresols, chlorophenols in environmental samples application of HPLC with amperometric detector is perspective. Phenols and chlorophenols can be easy oxidized and determined with high sensitivity on carbon-glass electrode. [Pg.129]

In order to reduce or eliminate off-line sample preparation, multidimensional chromatographic techniques have been employed in these difficult analyses. LC-GC has been employed in numerous applications that involve the analysis of poisonous compounds or metabolites from biological matrices such as fats and tissues, while GC-GC has been employed for complex samples, such as arson propellants and for samples in which special selectivity, such as chiral recognition, is required. Other techniques include on-line sample preparation methods, such as supercritical fluid extraction (SFE)-GC and LC-GC-GC. In many of these applications, the chromatographic method is coupled to mass spectrometry or another spectrometiic detector for final confirmation of the analyte identity, as required by many courts of law. [Pg.407]

Ethylenethiourea (ETU) is a toxic decomposition product/metabolite of alky-lenebis(dithiocarbamates). This compound could be generated during processing of treated crops at elevated temperature. Different chromatographic methods to determine the residue levels of ETU have been published. After extraction with methanol, clean-up on a Gas-Chrom S/alumina column and derivatization (alkylation) with bro-mobutane, ETU residues can be determined by GC with a flame photometric detector in the sulfur mode. Alternatively, ETU residues can also be determined by an HPLC method with UV detection at 240 nm or by liquid chromatography/mass spectrometry (LC/MS) or liquid chromatography/tandem mass spectrometry (LC/MS/MS) (molecular ion m/z 103). ... [Pg.1091]

The modem HPLC system is a very powerful analytical tool that can provide very accurate and precise analytical results. The sample injection volume tends to be a minor source of variation, although fixed-loop detectors must be flushed with many times their volume in sample to attain high precision. Assuming adequate peak resolution, fluorimetric, electrochemical, and UV detectors make it possible to detect impurities to parts per billion and to quantitate impurities to parts per thousand or, in favorable cases, to parts per million. The major sources of error in quantitation are sample collection and preparation. Detector response and details of the choice of chromatographic method may also be sources of error. [Pg.155]

Gas and liquid chromatography directly coupled with atomic spectrometry have been reviewed [178,179], as well as the determination of trace elements by chromatographic methods employing atomic plasma emission spectrometric detection [180]. Sutton et al. [181] have reviewed the use and applications of ICP-MS as a chromatographic and capillary electrophoretic detector, whereas Niessen [182] has briefly reviewed the applications of mass spectrometry to hyphenated techniques. [Pg.456]

Kublin and Kaniewska [52] used a gas chromatographic method for the determination of miconazole and other imidazole antimycotic substances. The conditions have been established for the quantitative determination of miconazole and the other drugs, which are present in pharmaceuticals such as ointments and creams. The column, packed with UCW-98 on Chromosorb WAW, and flame-ionization detector were used. The statistical data indicate satisfactory precision of the method, both in the determination of imidazole derivatives in substances and in preparation. [Pg.45]

Guo et al. [53] developed a gas chromatographic method for the analysis of miconazole nitrate in creams and injections. The conditions were flame ionization detector, stationary phase of 5% SE 30 support of Chromosorb W (AS-DMCS, 80—100 mesh) packed column 3 m x 3 mm column temperature 275 °C injection temperature 290 °C and diisooctyl sebacate and internal standard. The average recoveries for creams and injections were 97.7 and 101.4%, respectively. The relative standard deviations were 2.2 and 1.3%, respectively. [Pg.46]

Andreae [324,325] has described a gas chromatographic method for the determination of nanogram quantities of dimethyl sulfoxide in natural waters, seawater, and phytoplankton culture waters. The method uses chemical reduction with sodium borohydride to dimethyl sulfide, which is then determined gas-chromatographically using a flame photometric detector. [Pg.416]

The heptafluorobutyric anhydride derivative of pseudoephedrine and electron capture detector have been used to enhance the sensitivity of the gas chromatographic method. Lin and co-workers36 and Cummins and Fourier37 extracted basefied urine or serum with benzene. Heptafluorobutyric anhydride is added to the benzene extract. The heptafluoro-ibutyric anhydride derivative extracted was chromatographed... [Pg.504]

Detectors range from the universal, but less sensitive, to the very sensitive but limited to a particular class of compounds. The thermal conductivity detector (TCD) is the least sensitive but responds to all classes of compounds. Another common detector is the flame ionization detector (FID), which is very sensitive but can only detect organic compounds. Another common and very sensitive detector is called electron capture. This detector is particularly sensitive to halogenated compounds, which can be particularly important when analyzing pollutants such as dichlorodiphenyltrichloroethane (DDT) and polychlorobiphenyl (PCB) compounds. Chapter 13 provides more specific information about chromatographic methods applied to soil analysis. [Pg.186]

An official gas chromatographic method [29] is available from the determination of volatile fatty acids in sewage sludge. This method is based on gas liquid chromatographic estimation with a flame ionization detector, and is applicable up to 2000mg total volatile fatty acids per litre, while the concentrations of individual fatty acids can also be determined. Where this method is not practicable an empirical method based on the spectrophotometric determination of ferric hydroxamates can be used, giving a value for total fatty acids expressed as acetic acid. For control purposes a rapid test is described in which the volatile fatty acids are determined by electrometric titrimetry on the neutralized sludge obtained from the determination of alkalinity. [Pg.151]

Bilikova and Kuthan [87] developed a gas chromatographic method for the determination of submicrogram concentrations of Carbofuran (2,3-dihydro-2, 2,-dimethylbenzofuran-7-yl-methyl carbamate) in soils. Soil samples are mixed with methanol-water (80 20) and water samples are extracted with chloroform. After separation of the chloroform, and weak alkaline hydrolysis, derivatization is performed with l-fluoro-2,4-dinitrobenzene. The ester produced is isolated from benzene and cleaned up with acetone. The acetone extract is used to determine Carbofuran by gas chromatography with a nitrogen-specific detector. [Pg.231]

Neumayr [3] has discussed methods for sampling soil atmospheres and gives a detailed account of gas chromatographic methods employing electron capture and flame ionization detectors for detecting and estimating specific components of the soil atmosphere. [Pg.294]

Chromatographic methods have been applied with hydridization. Jackson et al. [98] used a commercial purge and trap apparatus fitted to a packed gas chromatographic column and flame photometric detector to achieve a O.lng detection. Purge and trap procedures followed by boiling point separations and detection by spectrophotometric methods yield detection limits in water of between 0.01 and lng. Detection of SnH emission by flame emission gives the greatest sensitivity. [Pg.422]

Non-specific sum parameter analysis [12,13], which is still used today, failed [14,15] in the analyses of some of these compounds. Chromatographic methods in combination with non-substance specific detectors, e.g. colorimetric and photometric [5] or with substance specific detectors such as IR (infrared spectroscopy), NMR (nuclear magnetic resonance spectroscopy) or MS (mass spectrometry), are applied increasingly nowadays. [Pg.257]

There are two basic approaches used to characterize seawater DOM (Benner, 2002). The first of these is to directly analyze bulk compositions (e.g., elemental or isotopic compositions) or individual compounds in the sample without concentration. This approach requires high-sensitivity methods for either broad biochemical types (e.g., total amino acids or carbohydrates) or individual compounds, often by either spectroscopic or chromatographic methods coupled to electrochemical or mass spectro-metric detectors. The latter type of molecular-level analyses are now feasible for measuring individual amino acids (Lindroth and Mopper, 1979), sugars (Skoog et al., 1999), and amino sugars (Kaiser and Benner,... [Pg.58]

One method (EPA 8020) that is suitable for volatile aromatic compounds is often referred to as benzene-toluene-ethylbenzene-xylene analysis, although the method includes other volatile aromatics. The method is similar to most volatile organic gas chromatographic methods. Sample preparation and introduction is typically by purge-and-trap analysis (EPA 5030). Some oxygenates, such as methyl-f-butyl ether (MTBE), are also detected by a photoionization detector, as well as olefins, branched alkanes, and cycloalkanes. [Pg.202]

Vanapalli SR, Kambhampati SP, Putcha L, Bourne DW. 2001. A liquid chromatographic method for the simultaneous determination of promethazine and three of its metabolites in plasma using electrochemical and UV detectors. J Chro-... [Pg.42]


See other pages where Detector chromatographic methods is mentioned: [Pg.53]    [Pg.201]    [Pg.116]    [Pg.127]    [Pg.945]    [Pg.14]    [Pg.453]    [Pg.77]    [Pg.115]    [Pg.110]    [Pg.546]    [Pg.732]    [Pg.254]    [Pg.127]    [Pg.28]    [Pg.225]    [Pg.472]    [Pg.110]    [Pg.20]    [Pg.369]    [Pg.239]    [Pg.393]    [Pg.45]    [Pg.456]    [Pg.1089]    [Pg.194]    [Pg.252]    [Pg.263]    [Pg.106]    [Pg.157]    [Pg.319]   


SEARCH



Chromatograph detector

Chromatographic detector

Chromatographic methods

© 2024 chempedia.info