Detection injection

Column switching time 1 Column switching time 2 Retention time Column temperature Detection Injection volume... [Pg.596]

Table 48.1 displays the detection, injection, and separation conditions as well as the different parameters for the sample mixture of H202 and AsA obtained using PMMA and Topas microchip with the end-channel Pt wire detector. [Pg.1283]

EPR s nal it does not contain free radicals. When O2 is injected into NO"-saturated 2-methylbutane, no color appears. Sometimes, a marginal EPR signal similar to the one found with the apparatus described above is detected. Injection of NO into N2-saturated 2-methylbutane likewise does not cause any color to show up, making sure that the red material results from reactions of O2 with NO. Despite the cmde method, we can provide solid arguments that the colored intermediate represents substantial amounts of the initial reactants. It may be a product of dead-end equilibria and not a stepping stone in the overall course of the autoxidation reaction, but hardly a minor contribution. Until to date, no molecule composed of N and O atoms only has been ft)und that has an extinction coefficient larger than 1000 cm in the visible spectral range. Peroxynitrite has an absorption maximum with... [Pg.351]

A in 40 min flow rate 1 mL/min detection charged aerosol detection injection volume lOpL peaks 200ng glucose (1), maltose (2), maltotriose (3), maltotetraose (4), malto-pentaose (5), maltohexaose (6), and maltohep-taose (7). [Pg.841]

Cocaine reduces fatigue, permits greater physical endurance, and gives a feeling of tremendous confidence and power. In some of the Sherlock Holmes stories, the great detective injects himself with a 7% solution of cocaine to overcome boredom. [Pg.739]

Natural tracers and polymers seem to be suitable low-cost tools to detect injected fluid breakthrough in the Tambaredjo pilot test. However, after two or more injectors are active, natural tracers and the polymers will not be able to establish specific connections with the producer wells. Synthetic tracers resolve this problem and increase the accnracy of the breakthrough detection. [Pg.295]

In contrast to a direct injection of dc or ac currents in the sample to be tested, the induction of eddy currents by an external excitation coil generates a locally limited current distribution. Since no electrical connection to the sample is required, eddy current NDE is easier to use from a practical point of view, however, the choice of the optimum measurement parameters, like e.g. the excitation frequency, is more critical. Furthermore, the calculation of the current flow in the sample from the measured field distribution tends to be more difficult than in case of a direct current injection. A homogenous field distribution produced by e.g. direct current injection or a sheet inducer [1] allows one to estimate more easily the defect geometry. However, for the detection of technically relevant cracks, these methods do not seem to be easily applicable and sensitive enough, especially in the case of deep lying and small cracks. [Pg.255]

The method implies injection of a mixture of 3 radioactive tracers each being distributed into one of the 3 phases. The tracers must show such differences in the emitting y-radiation energy spectra that they can be simultaneously detected by on line y-spectrometry. Candidate tracers are Br-82 as bromobenzene for oil, Na-24 or La-140 for water, and Kr-85 for gas. The tracers are injected simultaneously at a constant rate into the flow in the pressurised pipe, and the concentration is detected as series of instantaneous measurements taken downstream as illustrated in figure 2. [Pg.1056]

The methodology and the pigging tool have proven to be capable of identifying very small leaks. In oil pipelines like the Danish carrying 1500 m /h leakages down to 1 litre per hour can be detected without injection of large quantities of tracer. Leakages can be positioned with an accuracy of less than 1 metre. [Pg.1060]

A connnon teclmique used to enliance the signal-to-noise ratio for weak modes is to inject a local oscillator field polarized parallel to the RIKE field at the detector. This local oscillator field is derived from the probe laser and will add coherently to the RIKE field [96]. The relative phase of the local oscillator and the RIKE field is an important parameter in describing the optical heterodyne detected (OHD)-RIKES spectrum. If the local oscillator at the detector is in phase with the probe wave, the heterodyne mtensity is proportional to... [Pg.1208]

A microwave pulse from a tunable oscillator is injected into the cavity by an anteima, and creates a coherent superposition of rotational states. In the absence of collisions, this superposition emits a free-mduction decay signal, which is detected with an anteima-coupled microwave mixer similar to those used in molecular astrophysics. The data are collected in the time domain and Fourier transfomied to yield the spectrum whose bandwidth is detemimed by the quality factor of the cavity. Hence, such instruments are called Fourier transfomi microwave (FTMW) spectrometers (or Flygare-Balle spectrometers, after the inventors). FTMW instruments are extraordinarily sensitive, and can be used to examine a wide range of stable molecules as well as highly transient or reactive species such as hydrogen-bonded or refractory clusters [29, 30]. [Pg.1244]

Electrochemical Detectors Another common group of HPLC detectors are those based on electrochemical measurements such as amperometry, voltammetry, coulometry, and conductivity. Figure 12.29b, for example, shows an amperometric flow cell. Effluent from the column passes over the working electrode, which is held at a potential favorable for oxidizing or reducing the analytes. The potential is held constant relative to a downstream reference electrode, and the current flowing between the working and auxiliary electrodes is measured. Detection limits for amperometric electrochemical detection are 10 pg-1 ng of injected analyte. [Pg.585]

In a quantitative flow injection analysis a calibration curve is determined by injecting standard samples containing known concentrations of analyte. The format of the caK-bration curve, such as absorbance versus concentration, is determined by the method of detection. CaKbration curves for standard spectroscopic and electrochemical methods were discussed in Chapters 10 and 11 and are not considered further in this chapter. [Pg.655]

Carroll, M. K. Tyson, J. F. An Experiment Using Time-Based Detection in Flow Injection Analysis, /. Chem. Educ. 1993, 70, A210-A216. [Pg.660]

Schematic diagram showing the injection of a mixture of four substances (A, B, C, D) onto a GC column, foliowed by their separation into individuai components, their detection, and the dispiay (gas chromatogram) of the separated materiais emerging at different times from the coiumn. Schematic diagram showing the injection of a mixture of four substances (A, B, C, D) onto a GC column, foliowed by their separation into individuai components, their detection, and the dispiay (gas chromatogram) of the separated materiais emerging at different times from the coiumn.
Adsorption Chromatography. The principle of gas-sohd or Hquid-sohd chromatography may be easily understood from equation 35. In a linear multicomponent system (several sorbates at low concentration in an inert carrier) the wave velocity for each component depends on its adsorption equihbrium constant. Thus, if a pulse of the mixed sorbate is injected at the column inlet, the different species separate into bands which travel through the column at their characteristic velocities, and at the oudet of the column a sequence of peaks corresponding to the different species is detected. [Pg.264]

Tracer Type. A discrete quantity of a foreign substance is injected momentarily into the flow stream and the time interval for this substance to reach a detection point, or pass between detection points, is measured. From this time, the average velocity can be computed. Among the tracers that have historically been used are salt, anhydrous ammonia, nitrous oxide, dyes, and radioactive isotopes. The most common appHcation area for tracer methods is in gas pipelines where tracers are used to check existing metered sections and to spot-check unmetered sections. [Pg.67]


See other pages where Detection injection is mentioned: [Pg.1255]    [Pg.1267]    [Pg.1318]    [Pg.242]    [Pg.413]    [Pg.517]    [Pg.212]    [Pg.312]    [Pg.377]    [Pg.362]    [Pg.843]    [Pg.1194]    [Pg.545]    [Pg.295]    [Pg.1255]    [Pg.1267]    [Pg.1318]    [Pg.242]    [Pg.413]    [Pg.517]    [Pg.212]    [Pg.312]    [Pg.377]    [Pg.362]    [Pg.843]    [Pg.1194]    [Pg.545]    [Pg.295]    [Pg.83]    [Pg.335]    [Pg.1055]    [Pg.1977]    [Pg.570]    [Pg.585]    [Pg.585]    [Pg.589]    [Pg.605]    [Pg.609]    [Pg.649]    [Pg.664]    [Pg.664]    [Pg.651]    [Pg.52]    [Pg.241]   
See also in sourсe #XX -- [ Pg.603 ]




SEARCH



Batch injection analysis amperometric detection

Detection limits flow injection analysis

Flow Injection Immunoassay with Electrochemical Detection

Flow injection analysis , electrochemical detection

Flow injection analysis voltammetric detection

Flow injection-spectrophotometric detection

Flow-Injection Analysis with Electrochemical Detection

Flow-injection analysis amino acids, detection limit

Flow-injection analysis detection systems

Injection and Detection in HPLC