Detection calibration

Two different types of calibration marks are used in our experiments, planar circles and circular balls. The accuracy of the calibration procedure depends on the accuracy of the feature detection algorithms used to detect the calibration marks in the images. To take this in account, a special feature detection procedure based on accurate ellipses fitting has been developed. Detected calibration marks are rejected, if the feature detection procedure indicates a low reliability. [Pg.488]

Case IV - Analyte Detection (calibration curve determination). If a series of known concentration samples is measured, one can estimate (or verify) both the form and the parameters... [Pg.55]

Thanks are due David Kurtz for providing the Fenvalerate data and stimulating my interest in the detection-calibration problem. Helpful discussions with John Mandel concerning the Fenvalerate data set are also gratefully acknowledged. [Pg.72]

Cook s Distance Plot (Model Diagnostic) A statistic known as Cook s distance can be used to detect calibration data outliers by identilying which samples are most influential on the model. Now that the selected variables have been finalized, it is good practice to examine the calibration data for influential samples. These samples should be investigated and removed if it is determined that they have an unusual effect on the model. [Pg.313]

The enantiospecific determination of nimodipine in human plasma could be established by liquid chromatography-tandem mass-spectroscopy [27]. The separation was effected using a 8 pm Chiral OJ MOD column (25 cm x 2 mm i.d.), operated at 35°C with ethanol-n-heptane (1 4) containing 2 mM ammonium acetate as the mobile phase (flow rate of 300 pL/min) and MS detection. Calibration graphs were linear over the range of 0.5-75 ng/mL, with a detection limit of 0.25 ng/mL for each enantiomer. [Pg.364]

Calibration can be done every time you start a system up but for general leak detection, calibration is less important. However, whenever any general repair or replacement maintenance is performed, such as replacing the filament on a mass spectrometer, calibration becomes mandatory. See your owner s manual for specific instructions. [Pg.466]

The consecutive steps in speciation analysis are sample collection, sample conservation and storage, elimination of counterfeit samples, extraction/mineral-isation, derivatisation, separation, detection, calibration, calculation of results and evaluation of results [212, 234, 235]. [Pg.215]

Fig. 6. Limits of detection calibration curve for SPI mass spectrometry of DMMP... Fig. 6. Limits of detection calibration curve for SPI mass spectrometry of DMMP...
Soly/pH method Buffer solutions with pH values ranging between 6 and 13 were prepared. Powdered buprenorphine hydrochloride was added in excess of solubility to 3 ml of each buffer solution. The solutions were vortexed for 30 min and maintained at room temperature, 23.0 0.3 °C overnight. The solutions were filtered dirou 100 um MUlipore filters aided by reduced pressure. The clear filtrate was appropriately diluted and analysed by HPLC using fluorescence detection. Calibration curves were prepared simultaneously."... [Pg.120]

The coming decade will undoubtedly see an enormous expansion in the area of intelligent chemical instrumentation. Instrumental specifications will include automated features such as fault detection, calibration and temperature compensation, with the more advanced versions having the capacity to interpret sample composition. Increasing confidence in the results obtained from these instruments should generate more applications, which will in turn stimulate more progress. A movement towards solid state sensors will be required in order to obtain the vital extended sensor lifetimes and long-term stability. [Pg.56]

Fraser, A. J. and Taggart, C. T. (1988) Thin-layer chromatography-flame ionization detection calibration with natural and synthetic standards. Journal of Chromatography, 439, 404-7. [Pg.29]

To determine the number MWDs of the samples, the obtained dry polymers were dissolved in stabilized tetrahydrofuran (THF, Biosolve, A.R.) at 1 w/v% and filtrated using 0.2 pm filters. SEC analyses were carried out on a Waters 2690 Separation Module, using 4 PL-gel mix C columns (300 x 7.5 mm. Polymer Laboratories) at 40°C with THF as eluent at a flowrate of 1.0 mL min. A Waters 410 differential refractometer was used for detection. Calibration was performed using narrow-distribution polystyrene standards (Polymer Laboratories) ranging from 370 to 7.5 10 g moF. All SEC analyses were performed in duplicate. Only those traces for which comparable duplicate analyses were obtained, and the chromatogram baseline before and after elution of the polymer exhibited no non-linear variations were used for data analyses. Some discussion on the quality of the SEC set-up can... [Pg.123]

The choice between X-ray fluorescence and the two other methods will be guided by the concentration levels and by the duration of the analytical procedure X-ray fluorescence is usually less sensitive than atomic absorption, but, at least for petroleum products, it requires less preparation after obtaining the calibration curve. Table 2.4 shows the detectable limits and accuracies of the three methods given above for the most commonly analyzed metals in petroleum products. For atomic absorption and plasma, the figures are given for analysis in an organic medium without mineralization. [Pg.38]

Fig. 2 Conventional flat-bottom hole calibration standard for corrosion detection. Fig. 2 Conventional flat-bottom hole calibration standard for corrosion detection.
Measure Wall Thickness This window is used for the dialog to calibrate the algorithm aceording formula (3) and for point wise measurements after calibration. The row Ideal indicates the nominal wall thickness used, IQI indicates the wall thickness values used for calibration and the detected optical density. Local can be used for noise reduction and compensation of geometric effects. [Pg.564]

For interpretation of measuring results, calibration characteristics obtained on the samples in advance is used in the above instruments. However, if number of impediment factors increases, the interpretation of the signals detected becomes more complicated in many times. This fact causes the position that the object thickness T and crack length I are not taken into consideration in the above-mentioned instruments. It is considered that measuring error in this case is not significant. [Pg.645]

To determine time dependent behaviours of the specimen up to 25 measurements in series with different time delays are possible. To prevent mistakes in application many help comments appear when inputs are necessary or differences between the calibration and the measurement are detected. All calibration conditions, a description for the specimen and results can be printed or saved by the hard disk. To reduce the input expenditure, the last configuration is made to current values when the program is stopped ore leave. [Pg.869]

A measurement procedure has been developed that allows to determine the mass of the inclusions as well as their locations with respect to radius, angle, and depth (2). For the depth determination use is made of the approximate 1/R dependence of the magnetic field strength from the distance R to the inclusion When in a first measurement at a small lift off an inclusion is detected, the measurement is repeated at an increased lift off From the signal ratio the depth can be calculated or seen from a diagram like fig. 5a which was generated experimentally. After that, from calibration curves like fig. 5b the absolute value of the signal leads to the mass of the inclusion. [Pg.989]

The ppm scale is always calibrated relative to the appropriate resonance of an agreed standard compound, because it is not possible to detect the NMR of bare nuclei, even though absolute shieldings can be calculated... [Pg.1445]

In the ideal case for REMPI, the efficiency of ion production is proportional to the line strength factors for 2-photon excitation [M], since the ionization step can be taken to have a wavelength- and state-mdependent efficiency. In actual practice, fragment ions can be produced upon absorption of a fouitli photon, or the ionization efficiency can be reduced tinough predissociation of the electronically excited state. It is advisable to employ experimentally measured ionization efficiency line strengdi factors to calibrate the detection sensitivity. With sufficient knowledge of the excited molecular electronic states, it is possible to understand the state dependence of these intensity factors [65]. [Pg.2083]

In a quantitative flow injection analysis a calibration curve is determined by injecting standard samples containing known concentrations of analyte. The format of the caK-bration curve, such as absorbance versus concentration, is determined by the method of detection. CaKbration curves for standard spectroscopic and electrochemical methods were discussed in Chapters 10 and 11 and are not considered further in this chapter. [Pg.655]

A sample is to be analyzed following the protocol shown in Figure 15.2, using a method with a detection limit of 0.05 ppm. The relationship between the analytical signal and the concentration of the analyte, as determined from a calibration curve is... [Pg.723]

Calibration of an arc or spark source is linear over three orders of magnitude, and detection limits are good, often within the region of a few micrograms per gram for elements such as vanadium, aluminum, silicon, and phosphorus. Furthermore, the nature of the matrix material composing the bulk of the sample appears to have little effect on the accuracy of measurement. [Pg.114]

The U.S. Environmental Protection Agency publishes sets of Series Methods that describe procedures for detecting and estimating the quantity of environmentally hazardous substances. There are strict requirements for accuracy, reproducibility, and for calibration of mass spectrometers. [Pg.301]


See other pages where Detection calibration is mentioned: [Pg.945]    [Pg.296]    [Pg.946]    [Pg.50]    [Pg.4030]    [Pg.4039]    [Pg.508]    [Pg.169]    [Pg.945]    [Pg.296]    [Pg.946]    [Pg.50]    [Pg.4030]    [Pg.4039]    [Pg.508]    [Pg.169]    [Pg.10]    [Pg.97]    [Pg.163]    [Pg.166]    [Pg.286]    [Pg.484]    [Pg.487]    [Pg.490]    [Pg.778]    [Pg.1121]    [Pg.1283]    [Pg.1828]    [Pg.2964]    [Pg.2964]    [Pg.48]    [Pg.50]    [Pg.692]    [Pg.442]   