Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Control design elements

Wolf, T. and H. Bittermann (1997). Determination of adsorption parameters of active carbon filters measuring only the beginning of the breakthrough curve. SAE Special Publications Automotive Climate Control Design Elements, Proc. 1997 Int. Cong. Exposition Feb. 24—27, Detroit, MI, 1239, 51-54. SAE, Warrendale, PA. [Pg.433]

The Preservation standard is the existing condition or the New Construction/Reconstruction standard, whichever is less, for each of the 13 controlling design elements. Exempt projects include Pavement Preventive Maintenance projects, which apply where the pavement is in good condition with significant remaining service life. Preventive Maintenance projects do not significantly increase structural capacity, but use surface or near-surface treatments to structurally sound pavements to prevent deterioration of the pavement. [Pg.11]

The following are the 13 designated controlling design elements. Please rank these from 1 (most) to 13 (least) as to how important each Is for 3R projects. With the up or down arrows you can resort the list in order of importance. [Pg.52]

NH Need to be flexible with design standards when you can t meet the minimums due to type of work. Scope of work does not permit addressing all controlling design elements, and requires solid engineering judgment to develop cost-effective solutions to maximize highway and roadside safety. [Pg.85]

The demand for DRI varies depending on local market conditions. In industrialized countries, DRI primarily is used as a supplement to scrap for controlling residual elements in electric arc furnace steelmaking. In regions where scrap is scarce, DRI is used as a replacement in production of all grades of steel. In 1993, Latin America produced 9.4 X 10 t (39.3%) of the world s DRI. Middle East/North Africa produced 6.1 X 10 t (25.6%), Asia/Oceania produced 4.4 X 10 t (18.4%), and CIS/Eastem Europe produced 1.7 x 10 t (7.1%). North America produced 1.2 x 10 t (5.0%) Africa, 0.9 x 10 t (3.8%) and Western Europe, 0.2 x 10 t (0.8%) (1). Nearly 79% of the DRI produced is consumed in steel mills adjacent to the DR plants called captive plants. Plants which are designed to sell and ship DRI on the open market are called merchant plants. [Pg.431]

Process-variable feedback for the controller is achieved by one of two methods. The process variable can (I) be measured and transmitted to the controller by using a separate measurement transmitter with a 0.2-I.0-bar (3-15-psi pneumatic output, or (2) be sensed directly by the controller, which contains the measurement sensor within its enclosure. Controllers with integral sensing elements are available that sense pressure, differential pressure, temperature, and level. Some controller designs have the set point adjustment knob in the controller, making set point adjustment a local and manual operation. Other types receive a set point from a remotely located pneumatic source, such as a manual air set regulator or another controller, to achieve set point adjustment. There are versions of the pneumatic controller that support the useful one-, two-, and three-mode combinations of proportional, integral, and derivative actions. Other options include auto/manual transfer stations, antireset windup circuitry, on/off control, and process-variable and set point indicators. [Pg.776]

These nine rules of thumb represent tlie basic design elements of a pollution control system. Tlie engineering approach suggests tliat each element be evaluated independently and as part of the whole control system. However, tlie engineering design and evaluation must be an integrated part of the complete pollution control program. [Pg.384]

There is some confusion concerning terminology used for drug delivery when control of drug release is discussed. Within this chapter we will use an empirical approach. When a drug-delivery system does not contain any design element (formulation or process attribute) that is included to modify either spatial or... [Pg.752]

The official definition of quality is, the totality of features and characteristics of a product or service that bear upon its ability to satisfy stated or implied needs (ISO 8402). Well-planned design is one of the major contributing factors to achieving quality within a product or service. It is therefore necessary to carefully control critical elements of a company s documentation system with particular reference to each phase of design in order to ensure that the effects on the end products or services are not disastrous and are based on customer requirements. [Pg.8]

The (5)-tryptophan-derived oxazaborolidenes utilized in this aldol study have been previously examined by Corey as effective catalysts for enantioselective Diels-Alder cycloaddition reactions [6]. Corey has documented unique physical properties of the complex and has proposed that the electron-rich indole participates in stabilizing a donor-acceptor interaction with the metal-bound polarized aldehyde. More recently, Corey has formulated a model exemplified by 7 in which binding by the aldehyde to the metal is rigidified through the formation of a hydrogen-bond between the polarized formyl C-H and an oxyanionic ligand [7], The model illustrates the sophisticated design elements that can be incorporated into the preparation of transition-metal complexes that lead to exquisite control in aldehyde enantiofacial differentiation. [Pg.514]

The pneumatic controller is designed so that 0 to 100 percent output is also represented by 0.2 to 1.0 bar (3 to 15 psig). The output signal is sent through tubing to the control valve or other final control element. Most pneumatic controllers provide a manual control mode where the output pressure is manually set by operating personnel. The controller design also provides a mechanism to adjust the set point. [Pg.71]

If operated on clean, dry plant air, pneumatic controllers offer good performance and are extremely reliable. In many cases, however, plant air is neither clean nor dry. A poor-quality air supply will cause unreliable performance of pneumatic controllers, pneumatic field measurement devices, and final control elements. The main shortcoming of the pneumatic controller is its lack of flexibility when compared to modem electronic controller designs. Increased range of adjustability, choice of alternative control algorithms, the communication link to the control system, and other features and services provided by the electronic controller make it a superior choice in most of todays applications. Controller performance is also affected by the time delay induced by pneumatic tubing mns. For example, a 100-m run of 6.35-mm ( -in) tubing will typically cause 5 s of apparent process dead time, which will limit the control performance of fast processes such as flows and pressures. [Pg.72]

Some digital controller designs allow the execution rates of control strategy elements to be set independently of each other and indepen-... [Pg.72]

The state variables that provide valve position control are used to diagnose the health of the final control element. In addition, some digital valve controller designs integrate additional sensors into their construction to provide increased diagnostic capability. For example, pressure sensors are provided to detect supply pressure, actuator pressure (upper and lower cylinder pressures in the case of a springless piston actuator), and internal pilot pressure. Also, the position of the pneumatic relay valve is available in some designs to provide quiescent flow data used for leak detection in the actuator. [Pg.88]

The overall plant control concept and incorporation of more detailed control design with plant design requires the selection of the following elements ... [Pg.111]


See other pages where Control design elements is mentioned: [Pg.7]    [Pg.17]    [Pg.21]    [Pg.31]    [Pg.7]    [Pg.17]    [Pg.21]    [Pg.31]    [Pg.427]    [Pg.78]    [Pg.27]    [Pg.152]    [Pg.635]    [Pg.75]    [Pg.24]    [Pg.32]    [Pg.32]    [Pg.71]    [Pg.19]    [Pg.285]    [Pg.821]    [Pg.418]    [Pg.107]    [Pg.522]    [Pg.73]    [Pg.250]    [Pg.71]    [Pg.384]    [Pg.110]   