Another important use of BCl is as a Ftiedel-Crafts catalyst ia various polymerisation, alkylation, and acylation reactions, and ia other organic syntheses (see Friedel-Crafts reaction). Examples include conversion of cyclophosphasenes to polymers (81,82) polymerisation of olefins such as ethylene (75,83—88) graft polymerisation of vinyl chloride and isobutylene (89) stereospecific polymerisation of propylene (90) copolymerisation of isobutylene and styrene (91,92), and other unsaturated aromatics with maleic anhydride (93) polymerisation of norhornene (94), butadiene (95) preparation of electrically conducting epoxy resins (96), and polymers containing B and N (97) and selective demethylation of methoxy groups ortho to OH groups (98). [Pg.224]

The depth of the Bi film and diamond was chosen to give a frequency-independent absorption [65], The thermistor was glued to the diamond with a 40 xm drop of non-conductive epoxy. [Pg.341]

Fig. 8.5 Epoxy curing through resistive heating of nanocarbons dispersed in the matrix (a) shows a schematic representation of the process (b) experimentally obtained curing cycle and (c) repair of a structural composite panel using the conductive epoxy as resistively curable adhesive [36]. With kind permission from Elsevier (2013). Fig. 8.5 Epoxy curing through resistive heating of nanocarbons dispersed in the matrix (a) shows a schematic representation of the process (b) experimentally obtained curing cycle and (c) repair of a structural composite panel using the conductive epoxy as resistively curable adhesive [36]. With kind permission from Elsevier (2013).
Figure 4.15 — (A) Tubular flow-through electrode 1 Perspex body 2 conducting epoxy cylinder 3 mobile carrier PVC membrane 4 electric cable 5 channel (1.2 mm ID) 6 holders 7 screws 8 0-rings. (B) Schematic diagram of a system for on-line monitoring of ammonia ISE tubular flow-through ammonium ion-selective electrode R reference electrode W waste. (Reproduced from [137] with permission of the Royal Society of Chemistry). Figure 4.15 — (A) Tubular flow-through electrode 1 Perspex body 2 conducting epoxy cylinder 3 mobile carrier PVC membrane 4 electric cable 5 channel (1.2 mm ID) 6 holders 7 screws 8 0-rings. (B) Schematic diagram of a system for on-line monitoring of ammonia ISE tubular flow-through ammonium ion-selective electrode R reference electrode W waste. (Reproduced from [137] with permission of the Royal Society of Chemistry).
UMEs used in our laboratory were constructed by sealing of carbon fibre into low viscosity epoxy resin (see Fig. 32.4) [118]. This method is simple, rapid and no specialised instrumentation is required. Firstly, the fibres are cleaned with this aim. They are immersed in dilute nitric acid (10%), rinsed with distilled water, soaked in acetone, rinsed again with distilled water and dried in an oven at 70°C. A single fibre is then inserted into a 100- iL standard micropipette tip to a distance of 2 cm. A small drop of low-viscosity epoxy resin (A. R. Spurr, California) is carefully applied to the tip of the micropipette. Capillary action pulls the epoxy resin, producing an adequate sealing. The assembly is placed horizontally in a rack and cured at 70°C for 8h to ensure complete polymerization of the resin. After that, the electric contact between the carbon fibre and a metallic wire or rod is made by back-filling the pipette with mercury or conductive epoxy resin. Finally, the micropipette tip is totally filled with epoxy resin to avoid the mobility of the external connection. Then, the carbon fibre UME is ready. An optional protective sheath can be incorporated to prevent electrode damage. [Pg.781]

Conductive epoxy and hardener were purchased from Chemtronics, GA 30152, USA. [Pg.1078]

Obtain 1cm long PYC flexible tube (1.5 mm o.d.x 0.5 mm i.d.). Insert a cleaned metal wire across the tube. Seal both exterior parts of the metal wire with a drop of conductive epoxy. [Pg.1079]

The radiofrequency output from a function generator was coupled directly to the electrodes on the chip [95], Wires are attached to electrodes using a conductive epoxy. A 500 kHz electric field sine wave (60 kV cm4) was applied. [Pg.25]

For reasons of ease of manufacture, the majority of solid electrodes have a circular or rectangular form. External links are through a conducting epoxy resin either to a wire or to a solid rod of a metal such as brass, and the whole assembly is introduced by mechanical pressure into an insulating plastic sheath (Kel-F, Teflon, Delrin, perspex, etc.) or covered with epoxy resin. It is very important to ensure that there are no crevices between electrode and sheath where solution can enter and cause corrosion. Examples of electrodes constructed by this process will be shown in Chapter 8. [Pg.134]

Epoxies are excellent electrical insulators. Electrical properties are reduced on increasing the polarity of the molecules. Addition of metallic fillers, metallic wools and carbon black convert the non-conductive epoxy formulation into an electrically conductive system. Non-conductive fillers increase the arc resistance and to some extent increase the dielectric constant. [Pg.63]

Liq = liquid membrane with ion-exchange solution into the porous diaphgragm PVC = plasticized poly(vinyl chloride) Epoxy = conductive epoxy resin membrane. BA = benzyl alcohol BEHP = bis(2-Ethylhexyl)phthalate DA = 1-decanol DBP = dibutyl phthalate DBS = dibutyl sebacate DNP = dinonyl phthalate DOP = dioctyl phthalate NB = nitrobenzene NPOE = 2-nitrophenyl octyl ether NT = 2-nitrotoluene or 4-nitrotoluene OA = 1-octanol. [Pg.1513]

Inorganic fillers such as clays, CaCC>3, talc, silica, titanates, A1 and asbestos are commonly used in epoxy adhesives, as they are cheap and readily available. Conducting epoxies can be formulated with powdered copper metal or a mixture of a blend of Sn-Pb-Bi. [Pg.187]

A compact sensor of greatly reduced dimensions (outer diameter x length 36 x 46 mm) has been constructed and is shown in Fig. 2. In order to conveniently accommodate enzyme columns and to ensure isolation from ambient temperature fluctuations, a cylindrical copper heat sink was included. An outer Delrin jacket further improved the insulation. The enzyme column (inner diameter x length 3x4 mm), constructed of Delrin, was held tightly against the inner terminals of the copper core. Short pieces of well-insulated gold capillaries (outer diameter/inner diameter 0.3/0.2 mm) were placed next to the enzyme column as temperature-sensitive elements. Microbead thermistors were mounted on the capillaries with a heat-conducting epoxy. Two types of mini system has been constructed as discussed below. [Pg.9]

The low-index layer is perforated by many small ohmic contacts that cover only a small fraction of the entire area. The array of microcontacts allows the electrical current to pass through the dielectric layer. Assuming that the ohmic contacts have an area of 1 % of the reflector, and that the alloyed ohmic contact metal is 50% reflective, the reflectivity of the ODR is reduced by only 0.5%. The ODR described here can be used with low-cost Si substrates or metal substrates using conductive epoxy or a metal-to-metal bonding process. These bonding processes have much less stringent requirements than direct semiconductor-to-semi-conductor wafer bonding processes. [Pg.24]

Figure 7-8. (a) Impedance spectroscopy result for an ionically conductive epoxy composite [adapted with permission of S. Boob, 2003] (b) the equivalent circuit (inset) for the circular part of the response and (c) same as (b), but plotted on a frequency scale. [Pg.233]

Thin gold or aluminum wire, with a diameter of 0.025-0.075 mm, is used to make a connection between the bonding pad and the sensor. This wire bonding is performed using standard microelectronic techniques such as thermal compression or ultrasound bonding. The external lead wire is then bonded onto the bonding pad. Because of the thinness of the metallic film of the pad, the external lead wire connection is usually made by thermal compression. Similar to the connection of the thick-film sensor, the conductive epoxy is first applied to the connecting joint and then covered with insulation epoxy or silicone. [Pg.428]

Figure 20.1 A cross-section of an enzyme thermistor calorimeter with an aluminum constant-temperature jacket and and aluminum heat sink. The enlargement shows the attachment of a column and the transducer arrangement (a thermistor fixed with heat conducting epoxy to a gold tube). [Pg.495]

Epotherm. [Transene] Thermally conductive epoxy conqjds. [Pg.133]


See other pages where Epoxy conductive is mentioned: [Pg.330]    [Pg.189]    [Pg.137]    [Pg.198]    [Pg.330]    [Pg.369]    [Pg.370]    [Pg.447]    [Pg.742]    [Pg.1013]    [Pg.1079]    [Pg.340]    [Pg.341]    [Pg.299]    [Pg.568]    [Pg.659]    [Pg.382]    [Pg.123]    [Pg.431]    [Pg.166]    [Pg.10]    [Pg.142]    [Pg.532]    [Pg.269]    [Pg.92]    [Pg.51]    [Pg.441]    [Pg.90]    [Pg.488]   
See also in sourсe #XX -- [ Pg.382 ]




SEARCH



Conductive epoxy adhesives

Conductive epoxy bumps

Epoxies electrical conduction

Epoxies electrically conductive adhesives

Epoxy-based conductive adhesives

Thermal conductivity epoxies Table

Thermal conductivity epoxy adhesives

Thermal conductivity unfilled epoxies

© 2024 chempedia.info