Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Absorption chromatography

Wingen, L. M. Low, J. C. Pinlayson-Pitts, B. J. Chromatography, Absorption, and Pluorescence A New Instrumental Analysis Experiment on the Measurement of Polycyclic Aromatic Hydrocarbons in Cigarette Smoke, ... [Pg.613]

Bioassay methods include yeast fermentation polyneuritic rate of cure in rat bacterial metabolism. Physicochemical methods include thiochrome fluorescence polarography chromatography absorption in neutral and acid solutions,... [Pg.1611]

There are numerous properties of materials which can be used as measures of composition, e.g. preferential adsorption of components (as in chromatography), absorption of electromagnetic waves (infra-red, ultra-violet, etc.), refractive index, pH, density, etc. In many cases, however, the property will not give a unique result if there are more than two components, e.g. there may be a number of different compositions of a particular ternary liquid mixture which will have the same refractive index or will exhibit the same infra-red radiation absorption characteristics. Other difficulties can make a particular physical property unsuitable as a measure of composition for a particular system, e.g. the dielectric constant cannot be used if water is present as the dielectric constant of water is very much greater than that of most other liquids. Instruments containing optical systems (e.g. refractometers) and/or electromechanical feedback systems (e.g. some infra-red analysers) can be sensitive to mechanical vibration. In cases where it is not practicable to measure composition directly, then indirect or inferential means of obtaining a measurement which itself is a function of composition may be employed (e.g. the use of boiling temperature in a distillation column as a measure of the liquid composition—see Section 7.3.1). [Pg.497]

Liquid chromatography-absorption spectrophotometry was used by Vlacil and Hamplova [281] for the determination of lead and copper in natural waters. The metal diethyldithiocarbamates are extracted and concentrated by evaporation, followed by reversed phase liquid chromatography of the chelates. The copper and lead chelates can also be sequentially detected by spectrophotometry at 440 and 280nm. The detection limits for copper and lead were 8.6 and 17pg L 1 respectively, when liquid chromatography was used, and were 58 and 17pg L respectively when spectrophotometry was used. [Pg.144]

Note that in liquid phase chromatography there are no detectors that are both sensitive and universal, that is, which respond linearly to solute concentration regardless of its chemical nature. In fact, the refractometer detects all solutes but it is not very sensitive its response depends evidently on the difference in refractive indices between solvent and solute whereas absorption and UV fluorescence methods respond only to aromatics, an advantage in numerous applications. Unfortunately, their coefficient of response (in ultraviolet, absorptivity is the term used) is highly variable among individual components. [Pg.27]

Other methods for analyzing combustion products can be substituted for chromatography. Gravimetry can be used, for example, after a series of absorption on different beds, as in the case of water absorption in magnesium perchlorate or CO2 in soda lime infra-red spectrometry can be used for the detection of CO2 and water. [Pg.29]

Analytical and Test Methods. o-Nitrotoluene can be analyzed for purity and isomer content by infrared spectroscopy with an accuracy of about 1%. -Nitrotoluene content can be estimated by the decomposition of the isomeric toluene diazonium chlorides because the ortho and meta isomers decompose more readily than the para isomer. A colorimetric method for determining the content of the various isomers is based on the color which forms when the mononitrotoluenes are dissolved in sulfuric acid (45). From the absorption of the sulfuric acid solution at 436 and 305 nm, the ortho and para isomer content can be deterrnined, and the meta isomer can be obtained by difference. However, this and other colorimetric methods are subject to possible interferences from other aromatic nitro compounds. A titrimetric method, based on the reduction of the nitro group with titanium(III) sulfate or chloride, can be used to determine mononitrotoluenes (32). Chromatographic methods, eg, gas chromatography or high pressure Hquid chromatography, are well suited for the deterrnination of mononitrotoluenes as well as its individual isomers. Freezing points are used commonly as indicators of purity of the various isomers. [Pg.70]

The sodium hydroxide is titrated with HCl. In a thermometric titration (92), the sibcate solution is treated first with hydrochloric acid to measure Na20 and then with hydrofluoric acid to determine precipitated Si02. Lower sibca concentrations are measured with the sibcomolybdate colorimetric method or instmmental techniques. X-ray fluorescence, atomic absorption and plasma emission spectroscopies, ion-selective electrodes, and ion chromatography are utilized to detect principal components as weU as trace cationic and anionic impurities. Eourier transform infrared, ft-nmr, laser Raman, and x-ray... [Pg.11]

Several properties of the filler are important to the compounder (279). Properties that are frequentiy reported by fumed sihca manufacturers include the acidity of the filler, nitrogen adsorption, oil absorption, and particle size distribution (280,281). The adsorption techniques provide a measure of the surface area of the filler, whereas oil absorption is an indication of the stmcture of the filler (282). Measurement of the sdanol concentration is critical, and some techniques that are commonly used in the industry to estimate this parameter are the methyl red absorption and methanol wettabihty (273,274,277) tests. Other techniques include various spectroscopies, such as diffuse reflectance infrared spectroscopy (drift), inverse gas chromatography (igc), photoacoustic ir, nmr, Raman, and surface forces apparatus (277,283—290). [Pg.49]

Chromatographic methods, notably hplc, are available for the simultaneous deterrnination of ascorbic acid as weU as dehydroascorbic acid. Some of these methods result in the separation of ascorbic acid from its isomers, eg, erythorbic acid and oxidation products such as diketogulonic acid. Detection has been by fluorescence, uv absorption, or electrochemical methods (83—85). Polarographic methods have been used because of their accuracy and their ease of operation. Ion exclusion (86) and ion suppression (87) chromatography methods have recently been reported. Other methods for ascorbic acid deterrnination include enzymatic, spectroscopic, paper, thin layer, and gas chromatographic methods. ExceUent reviews of these methods have been pubHshed (73,88,89). [Pg.17]

Spectrophotometric deterrnination at 550 nm is relatively insensitive and is useful for the deterrnination of vitamin B 2 in high potency products such as premixes. Thin-layer chromatography and open-column chromatography have been appHed to both the direct assay of cobalamins and to the fractionation and removal of interfering substances from sample extracts prior to microbiological or radioassay. Atomic absorption spectrophotometry of cobalt has been proposed for the deterrnination of vitamin B 2 in dry feeds. Chemical methods based on the estimation of cyanide or the presence of 5,6-dimethylben2irnida2ole in the vitamin B 2 molecule have not been widely used. [Pg.115]

Since 1970, new analytical techniques, eg, ion chromatography, have been developed, and others, eg, atomic absorption and emission, have been improved (1—5). Detection limits for many chemicals have been dramatically lowered. Many wet chemical methods have been automated and are controlled by microprocessors which allow greater data output in a shorter time. Perhaps the best known continuous-flow analy2er for water analysis is the Autoanaly2er system manufactured by Technicon Instmments Corp. (Tarrytown, N.Y.) (6). Isolation of samples is maintained by pumping air bubbles into the flow line. Recently, flow-injection analysis has also become popular, and a theoretical comparison of it with the segmented flow analy2er has been made (7—9). [Pg.230]

Chemical stabiUty studies are monitored by siUca gel thin-layer chromatography (dc) or by high performance Hquid chromatography (hplc) using a reverse-phase C g coated column (24). Hplc peaks or dc spots are visualized by thek uv absorption at 245 nm the tic spots can also be detected by ceric sulfate or phosphomolybdic acid staining. [Pg.281]

Total carbon in beryUium is determined by combustion of the sample, along with an accelerator mixture of tin, iron, and copper, in a stream of oxygen (15,16). The evolved carbon dioxide is usuaUy measured by infrared absorption spectrometry. BeryUium carbide can be determined without interference from graphitic carbon by dissolution of the sample in a strong base. BeryUium carbide is converted to methane, which can be determined directly by gas chromatography. Alternatively, the evolved methane can be oxidized to carbon dioxide, which is determined gravimetricaUy (16). [Pg.69]

The acetyl content of cellulose acetate may be calculated by difference from the hydroxyl content, which is usually determined by carbanilation of the ester hydroxy groups in pyridine solvent with phenyl isocyanate [103-71-9J, followed by measurement of uv absorption of the combined carbanilate. Methods for determining cellulose ester hydroxyl content by near-infrared spectroscopy (111) and acid content by nmr spectroscopy (112) and pyrolysis gas chromatography (113) have been reported. [Pg.257]

A number of analytical methods have been developed for the determination of chlorotoluene mixtures by gas chromatography. These are used for determinations in environments such as air near industry (62) and soil (63). Liquid crystal stationary columns are more effective in separating m- and chlorotoluene than conventional columns (64). Prepacked columns are commercially available. ZeoHtes have been examined extensively as a means to separate chlorotoluene mixtures (see Molecularsieves). For example, a Y-type 2eohte containing sodium and copper has been used to separate y -chlorotoluene from its isomers by selective absorption (65). The presence of ben2ylic impurities in chlorotoluenes is determined by standard methods for hydroly2able chlorine. Proton (66) and carbon-13 chemical shifts, characteristic in absorption bands, and principal mass spectral peaks are available along with sources of reference spectra (67). [Pg.54]

The purity of cyclobutanone was checked by gas chromatography on a 3.6-m. column containing 20% silicone SE 30 on chromosorb W at 65°. The infrared spectrum (neat) shows carbonyl absorption at 1779 cm. - the proton magnetic resonance spectrum (carbon tetrachloride) shows a multiplet at 8 2.00 and a triplet at S 3.05 in the ratio 1 2. [Pg.39]

Pretreatment of the collected particulate matter may be required for chemical analysis. Pretreatment generally involves extraction of the particulate matter into a liquid. The solution may be further treated to transform the material into a form suitable for analysis. Trace metals may be determined by atomic absorption spectroscopy (AA), emission spectroscopy, polarogra-phy, and anodic stripping voltammetry. Analysis of anions is possible by colorimetric techniques and ion chromatography. Sulfate (S04 ), sulfite (SO-, ), nitrate (NO3 ), chloride Cl ), and fluoride (F ) may be determined by ion chromatography (15). [Pg.206]


See other pages where Absorption chromatography is mentioned: [Pg.53]    [Pg.766]    [Pg.53]    [Pg.766]    [Pg.513]    [Pg.116]    [Pg.613]    [Pg.770]    [Pg.68]    [Pg.420]    [Pg.487]    [Pg.381]    [Pg.378]    [Pg.132]    [Pg.221]    [Pg.316]    [Pg.244]    [Pg.250]    [Pg.71]    [Pg.432]    [Pg.69]    [Pg.417]    [Pg.110]    [Pg.116]    [Pg.52]    [Pg.61]    [Pg.551]    [Pg.562]    [Pg.545]   
See also in sourсe #XX -- [ Pg.591 ]

See also in sourсe #XX -- [ Pg.3 ]




SEARCH



Atomic absorption spectrometry with liquid chromatography

Chromatography column absorption

Gas chromatography-atomic absorption

Gas chromatography-atomic absorption spectrometry

High-performance liquid chromatography with atomic absorption spectrometry

High-performance liquid chromatography with hydride generation atomic absorption

Interface liquid chromatography-atomic absorption

Liquid chromatography-atomic absorption

Liquid chromatography-atomic absorption spectrometry

Liquid chromatography-hydride generation atomic absorption spectrometry

Molar absorptivity chromatography

Supercritical fluid chromatography absorption

© 2024 chempedia.info