Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Measurement composition

SDY(I) cols 1-10 standard deviation of pressure measurement SDX(I,l)cols 11-20 standard deviation of temperature measurement SDX(l,2)cols 21-30 standard deviation of liquid composition measurement... [Pg.227]

SDZ(I) cols 31-40 standard deviation of vapor composition measurement... [Pg.227]

EVX(I,2) - ERROR VARRIANCE OF THF LIQUID-PHASE COMPOSITION MEASUREMENT. [Pg.234]

Atmospheric ions are important in controlling atmospheric electrical properties and conmumications and, in certain circumstances, aerosol fomiation [128. 130. 131. 138. 139, 140. 141. 142, 143, 144 and 145]. In addition, ion composition measurements can be used to derive trace neutral concentrations of the species involved in the chemistry. Figure A3.5.11 shows the total-charged-particle concentration as a frmction of... [Pg.817]

Hauck G and Arnold F 1984 Improved positive-ion composition measurements in the upper troposphere and lower stratosphere and the detection of acetone Nature 311 547-50... [Pg.828]

We should mention here that using just similarity or dissimilarity in a similarity measure might be misleading. Therefore, some composite measures using both similarity and dissimilarity have been developed. These are the Hamann and the Yule measures (Table 6-2). A simple product of (1 - Tanimoto) and squared Eucli-... [Pg.304]

Time-Delay Compensation Time delays are a common occurrence in the process industries because of the presence of recycle loops, fluid-flow distance lags, and dead time in composition measurements resulting from use of chromatographic analysis. The presence of a time delay in a process severely hmits the performance of a conventional PID control system, reducing the stability margin of the closed-loop control system. Consequently, the controller gain must be reduced below that which could be used for a process without delay. Thus, the response of the closed-loop system will be sluggish compared to that of the system with no time delay. [Pg.733]

There are numerous solubility data in the literature the standard reference is by Seidell (loc. cit.). Valuable as they are, they nevertheless must be used with caution because the solubihty of compounds is often influenced by pH and/or the presence of other soluble impurities which usually tend to depress the solubihty of the major constituents. While exact values for any system are frequently best determined by actual composition measurements, the difficulty of reproducing these solubility diagrams should not be underestimated. To obtain data which are readily reproducible, elaborate pains must be taken to be sure the system sampled is at equihbrium, and often this means holding a sample at constant temperature for a period of from 1 to 100 h. While the published cui ves may not be exac t for actual solutions of interest, they generally will be indicative of the shape of the solubility cui ve and will show the presence of hydrates or double salts. [Pg.1654]

Spreadsheet Structure There are three principal sections to the spreadsheet. The first has tables of as-reported and normalized composition measurements. The second section has tables for overall and component flows. These are used to check the overall and component material balance constraints. The third has adjusted stream and component flows. Space is provided for recording the basis of the adjustments. The structure changes as the breadth and depth of the analysis increases. [Pg.2567]

Recommendation When all measurements were recorded by hand, operators and engineers could use their judgment concerning their validity. Now with most acqmred automatically in enormous numbers, the measurements need to be examined automatically. The goal continues to be to detect correctly the presence or absence of gross errors and isolate which measurements contain those errors. Each of the tests has limitations. The hterature indicates that the measurement test or a composite test where measurements are sequentially added to the measurement set are the most powerful, but their success is limited. If automatic analysis is required, the composite measurement test is the most direct to isolation-specific measurements with gross error. [Pg.2572]

One final point should be made. The observation of significant solvent effects on kp in homopolymerization and on reactivity ratios in copolymerization (Section 8.3.1) calls into question the methods for reactivity ratio measurement which rely on evaluation of the polymer composition for various monomer feed ratios (Section 7.3.2). If solvent effects arc significant, it would seem to follow that reactivity ratios in bulk copolymerization should be a function of the feed composition.138 Moreover, since the reaction medium alters with conversion, the reactivity ratios may also vary with conversion. Thus the two most common sources of data used in reactivity ratio determination (i.e. low conversion composition measurements and composition conversion measurements) are potentially flawed. A corollary of this statement also provides one explanation for any failure of reactivity ratios to predict copolymer composition at high conversion. The effect of solvents on radical copolymerization remains an area in need of further research. [Pg.361]

Zinsmeister, A. R. and Redman, T. C. (1980). A time series analysis of aerosol composition measurements, Atmos. Environ. 14,201-215. [Pg.321]

The utility of c) as a thermometer gains further support from direct measurements showing correlation of temperature and 3 of precipitation through time over seasonal cycles (Shuman et al, 1995). At longer temporal scales, temperature measurements in boreholes and gas composition measurements both provide temperature information which can be compared to 3. Results from such comparisons have so far... [Pg.472]

Apparatus and Procedure. The apparatus and procedure were identical to those outlined in ref. Surface composition measurements were based on an O2-CO titration technique described by Miura and Gonzalez (5-6). The ratio of surface metal/02/CO was 1/1/T on Ru-sllica, 1/0.5/1.75 on Rh-sllica, 1/0.5/2.0 on Pt-silica and 1/0.5/1.6 on Ir-silica. These titration ratios were found to be independent of surface composition. Surface compositions determined by the O2-CO titration method have been verified using a variety of experimental techniques (2,5-6). [Pg.295]

Surface Composition Measurements. The surface composition and metal dispersion for a series of silica (Cab-O-Sll) supported Ru-Rh bimetallic clusters are summarized In Table I. Surface enrichment In Rh, the element with the lower heat of sublimation, was not observed over the entire bimetallic composition range. In fact, to within the experimental limit of error of the measurements, surface compositions and catalyst compositions were nearly equal. A small local maximum In the dispersion was observed for the catalyst having a surface composition of 50% Rh. [Pg.296]

Results are shown in Figures 10 and 11. HPLC is well known as a reproducible and accurate technique for composition measurement From the point of view of kinetic model development however, the following points deserve emphasis. [Pg.163]

Principal component regression (PCR) is an extension of PCA with the purpose of creating a predictive model of the Y-data using the X or measurement data. For example, if X is composed of temperatures and pressures, Y may be the set of compositions that results from thermodynamic considerations. Piovoso and Kosanovich (1994) used PCR and a priori process knowledge to correlate routine pressure and temperature measurements with laboratory composition measurements to develop a predictive model of the volatile bottoms composition on a vacuum tower. [Pg.35]

Figure 3 shows the excess enthalpy v . composition measured for aqueous solutions of n-butanol and water at 30.0 °C Figure 4 shows corresponding results for the amphiphilic side of the miscibility gap at... [Pg.298]

Copolymer composition vs. monomer feed data were then obtained for 1-hexene (M ) and 5-methyl-1,4-hexadiene copolymerizations (Table VI). The data show that the copolymer compositions measured by 300 MHz %-NMR spectroscopy are essentially identical to the monomer feed. The calculated reactivity ratios were 1.1 + 0.2 for each of the two monomers. [Pg.187]

All of the results discussed to this point infer surface coverages from gas phase composition measurements. Although these inferences are soundly based in the case of CO oxidation, we would be much more comfortable with direct measurement of the surface coverage. [Pg.41]

Compound 22 can be conveniently prepared in multigram quantities and has been found to be useful for assessing the enantiomeric purity of 1,2-glycols. Because the ketal carbon represents a new chiral center, the formation of four diastereomers is possible. However, the diastereomeric pair 23a and 23b (or 23c and 23d) shows 1 1 peak height in 13C NMR or equal peak areas in HPLC the diastereomer composition measured by the ratio of 23a to 23b or 23c to 23d reflects the enantiomer composition of the original 1,2-glycol. [Pg.25]

Composition measurement, 77 785 Composition of matter category, in patents, 78 165-166... [Pg.206]


See other pages where Measurement composition is mentioned: [Pg.818]    [Pg.307]    [Pg.408]    [Pg.22]    [Pg.749]    [Pg.432]    [Pg.141]    [Pg.173]    [Pg.579]    [Pg.177]    [Pg.145]    [Pg.115]    [Pg.448]    [Pg.316]    [Pg.531]    [Pg.293]    [Pg.160]    [Pg.198]    [Pg.98]    [Pg.305]    [Pg.300]    [Pg.256]    [Pg.494]    [Pg.390]   
See also in sourсe #XX -- [ Pg.495 ]

See also in sourсe #XX -- [ Pg.171 , Pg.172 , Pg.173 ]

See also in sourсe #XX -- [ Pg.620 ]




SEARCH



Acid composition calorimetric measurements

Analytical methods, measuring copolymer composition

Chemical composition, aerosol measurements

Chemical compositions physical measurements

Composition Measurement Location

Copolymer composition measurement methods

Dense composite membranes membrane flux measurements

Dilute solution composition measures

Film composition measurements

High-Resolution, Accurate Mass Measurement Elemental Compositions

How to Measure Surface Reactions of Cathode Materials and Relevant Composite Electrodes

Ionic polymer-metal composite Measurement

Measurement Methods, Polymer Characterization, Compositions

Measurement methods particle composition

Measures of Composition

Measuring colour and pigment composition

Measuring stresses in FRP composite bonded joints

Molecular composites mobility measurement

Phase equilibria composition measurement

Products, detonation measured” product compositions

Quantitative compositional measurement

Similarity measures composition determined

The measurement of composition

© 2024 chempedia.info