Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Characteristic solid phases

Principles and Characteristics Solid-phase extraction (SPE) is a very popular sample preparation and clean-up technique. In SPE solutes are extracted from a liquid (or gaseous) phase into a solid phase. Substances that have been extracted by the solid particles can be removed by washing with an appropriate liquid eluent. Usually, the volume of solvent needed for complete elution of the analytes is much smaller (typically < 1 mL) than the original sample volume. A concentration of the analytes is thus achieved. [Pg.124]

Principles and Characteristics Solid-phase microextraction (SPME) is a patented microscale adsorp-tion/desorption technique developed by Pawliszyn et al. [525-531], which represents a recent development in sample preparation and sample concentration. In SPME analytes partition from a sample into a polymeric stationary phase that is thin-coated on a fused-silica rod (typically 1 cm x 100 p,m). Several configurations of SPME have been proposed including fibre, tubing, stirrer/fan, etc. SPME was introduced as a solvent-free sample preparation technique for GC. [Pg.129]

When reacting two substrates in solution (solution phase) to form a desired product (Ri-E1-Nu-R2 in Fig. 1), a resin with the desired characteristics (solid phase) is utilized to trap undesired material. A scavenging resin, usually added upon reacting of the substrates, interacts with the undesired reagent, thus forming a chemically modified new resin. Upon simple filtration, this resin is separated from the reaction mixture providing (in some cases clean) product without further purification being necessary. [Pg.395]

The three general states of monolayers are illustrated in the pressure-area isotherm in Fig. IV-16. A low-pressure gas phase, G, condenses to a liquid phase termed the /i uid-expanded (LE or L ) phase by Adam [183] and Harkins [9]. One or more of several more dense, liquid-condensed phase (LC) exist at higher pressures and lower temperatures. A solid phase (S) exists at high pressures and densities. We briefly describe these phases and their characteristic features and transitions several useful articles provide a more detailed description [184-187]. [Pg.131]

In the present work, the technique of XO and MTB immobilization onto silica gel in the form of its complexes with Fe(III) and Bi(III) respectively were found. The acid - base and chemical-analytical characteristics of solid-phase reagents were examined. The optimal conditions of quantitative recovery of Pb(II) and Zn(II) from diluted solutions, such as acidity of aqueous phase, the mass of the sorbents, the volume of solutions and the time of equilibrium reaching, were found. The methods of and F" detenuination were based on a competitive reactions of Zr(IV) with immobilized MTB and or F". Optimal conditions of 0,0 and F" determination in solution using SG, modified ion associates QAS-MTB (pH = 1,5, = 5-10 mol/1). [Pg.334]

A powerful tool now employed is that of diode array detection (DAD). This function allows peaks detected by UV to be scanned, and provides a spectral profile for each suspected microcystin. Microcystins have characteristic absorption profiles in the wavelength range 200-300 nm, and these can be used as an indication of identity without the concomitant use of purified microcystin standards for all variants. A HPLC-DAD analytical method has also been devised for measurement of intracellular and extracellular microcystins in water samples containing cyanobacteria. This method involves filtration of the cyanobacteria from the water sample. The cyanobacterial cells present on the filter are extracted with methanol and analysed by HPLC. The filtered water is subjected to solid-phase clean-up using C g cartridges, before elution with methanol and then HPLC analysis. [Pg.118]

Lateral density fluctuations are mostly confined to the adsorbed water layer. The lateral density distributions are conveniently characterized by scatter plots of oxygen coordinates in the surface plane. Fig. 6 shows such scatter plots of water molecules in the first (left) and second layer (right) near the Hg(l 11) surface. Here, a dot is plotted at the oxygen atom position at intervals of 0.1 ps. In the first layer, the oxygen distribution clearly shows the structure of the substrate lattice. In the second layer, the distribution is almost isotropic. In the first layer, the oxygen motion is predominantly oscillatory rather than diffusive. The self-diffusion coefficient in the adsorbate layer is strongly reduced compared to the second or third layer [127]. The data in Fig. 6 are qualitatively similar to those obtained in the group of Berkowitz and coworkers [62,128-130]. These authors compared the structure near Pt(lOO) and Pt(lll) in detail and also noted that the motion of water in the first layer is oscillatory about equilibrium positions and thus characteristic of a solid phase, while the motion in the second layer has more... [Pg.361]

Sodium reduction development directions, 336 diluted melts, 331-332 of K-Salt, 327-328 principals, 326 Solid-phase interaction mechanism, 34-37 niobium oxyfluorides, 26-31 tantalum oxyfluorides, 32-34 Solubility diagrams (NH4)5Nb3OF18, 22 K2NbF7 in HF solutions, 14 K2TaF7 in HF solutions, 14 RbsNbjOF,, 22-23 Solubility of peroxides, 307 Specific conductivity, 153, 164 Spontaneous polarization, 223 Structural characteristics for X Me=8, 61,... [Pg.388]

The boundary layers, or interphases as they are also called, form the mesophase with properties different from those of the bulk matrix and result from the long-range effects of the solid phase on the ambient matrix regions. Even for low-molecular liquids the effects of this kind spread to liquid layers as thick as tens or hundreds or Angstrom [57, 58], As a result the liquid layers at interphases acquire properties different from properties in the bulk, e.g., higher shear strength, modified thermophysical characteristics, etc. [58, 59], The transition from the properties prevalent in the boundary layers to those in the bulk may be sharp enough and very similar in a way to the first-order phase transition [59]. [Pg.8]

A reaction interface is the zone immediately adjoining the surface of contact between reactant and product and within which bond redistributions occur. Prevailing conditions are different from those characteristic of the reactant bulk as demonstrated by the enhanced reactivity, usually attributed to local strain, catalysis by products, etc. Considerable difficulties attend investigation of the mechanisms of interface reactions because this thin zone is interposed between two relatively much larger particles. Accordingly, many proposed reaction models are necessarily based on indirect evidence. Without wishing to appear unnecessarily pessimistic, we consider it appropriate to mention here some of the problems inherent in the provision of detailed mechanisms for solid phase rate processes. These difficulties are not always apparent in interpretations and proposals appearing in the literature. [Pg.109]

Determination of the influence of crystal structure and reactant environment on deammination and dehydration processes is complicated by the several solid phase transformations that are a characteristic feature of many ammonium salts. Sublimation and/or melting may also occur. Deammination and dehydration steps are generally reversible. At high temperatures, however, particularly in the presence of a residual oxide... [Pg.195]

As with solid phase decompositions (Sect. 1), the kinetic characteristics of solid—solid interactions are controlled by the properties of lattice imperfections, though here many systems of interest involve the migration, in a crystal bulk of a mobile participant, from one interface to another. Kinetic measurements have been determined for reactions in a number of favourable systems, but there remain many possibilities for development in a field that is at present so largely unexplored. [Pg.287]

Energy must also be provided to melt a solid substance. This energy is used to overcome the intermolecular forces that hold molecules or ions in fixed positions in the solid phase. Thus, the melting of a solid also has characteristic energy and enthalpy changes. The heat needed to melt one mole of a substance at its normal melting point is called the molar heat of fusion, Ai/fas... [Pg.804]

Most solid materials produce isotropic liquids directly upon melting. However, in some cases one or more intermediate phases are formed (called mesophases), where the material retains some ordered structure but already shows the mobility characteristic of a liquid. These materials are liquid crystal (LCs)(or mesogens) of the thermotropic type, and can display several transitions between phases at different temperatures crystal-crystal transition (between solid phases), melting point (solid to first mesophase transition), mesophase-mesophase transition (when several mesophases exist), and clearing point (last mesophase to isotropic liquid transition) [1]. Often the transitions are observed both upon heating and on cooling (enantiotropic transitions), but sometimes they appear only upon cooling (monotropic transitions). [Pg.357]

Table 3.44 Characteristics of solid-phase extraction Advantages... Table 3.44 Characteristics of solid-phase extraction Advantages...
Principles and Characteristics As mentioned already (Section 3.5.2) solid-phase microextraction involves the use of a micro-fibre which is exposed to the analyte(s) for a prespecified time. GC-MS is an ideal detector after SPME extraction/injection for both qualitative and quantitative analysis. For SPME-GC analysis, the fibre is forced into the chromatography capillary injector, where the entire extraction is desorbed. A high linear flow-rate of the carrier gas along the fibre is essential to ensure complete desorption of the analytes. Because no solvent is injected, and the analytes are rapidly desorbed on to the column, minimum detection limits are improved and resolution is maintained. Online coupling of conventional fibre-based SPME coupled with GC is now becoming routine. Automated SPME takes the sample directly from bottle to gas chromatograph. Split/splitless, on-column and PTV injection are compatible with SPME. SPME can also be used very effectively for sample introduction to fast GC systems, provided that a dedicated injector is used for this purpose [69,70],... [Pg.437]


See other pages where Characteristic solid phases is mentioned: [Pg.449]    [Pg.449]    [Pg.1960]    [Pg.82]    [Pg.7]    [Pg.1993]    [Pg.112]    [Pg.435]    [Pg.485]    [Pg.61]    [Pg.82]    [Pg.377]    [Pg.397]    [Pg.247]    [Pg.933]    [Pg.936]    [Pg.990]    [Pg.2]    [Pg.41]    [Pg.86]    [Pg.141]    [Pg.348]    [Pg.326]    [Pg.81]    [Pg.131]    [Pg.19]    [Pg.20]    [Pg.241]    [Pg.66]    [Pg.7]    [Pg.146]    [Pg.553]    [Pg.922]    [Pg.8]   


SEARCH



Phase characteristic

Solid-phase extraction characteristics

Solid-phase microextraction characteristics

© 2024 chempedia.info