Camera system

On the other hand it is well known that the hnman eye can adapt to changing inspection conditions in recognizing flaws while a camera system is not able to adapt automatically. [Pg.628]

The QAP system additionally was developped for inspection documentation purposes to meet the modern requirements in process documentation (ISO 9000). It is the basic system required to install a fully automated inspection by a camera system and image processing. [Pg.629]

If the inspection equipment can be run under stable and reproducable conditions due to the QAP the basis for using a camera system for flaw detection is given.The camera system consists of CCD-cameras and a pattern recognition software. Up to four CCD-cameras can be served by one PC. One shot of the part may be copied up to 16 times in the computer and this theoretically enables the crack determination with 16 different parameter sets. [Pg.630]

The camera system itsself has to be self monitoring which is given by an artificial crack always being processed together with every inspected part. Missing of this signal leads to an... [Pg.630]

The QAP enables the user to have a consistent documentation of the variable parameters and inspection results (with camera system). A protocol can be printed out to be used as documentation for the equipment and inspection. [Pg.631]

Tire development of the QAP system for the MPI and LPl technique together with a camera system for automated flaw detection can give the following advantages ... [Pg.631]

Although energy resolution is rarely employed in positron camera systems, scatter is not normally a problem. This is because of the very short time window within which two photons must arrive in order to be counted. At low decay rates, the incidence of accidental events is very low, rising only slightly for those that occur as the result of scatter. Some systems employ time-of-flight measurements of the time difference between the arrival of the two photons to obtain additional information about the location of an annihilation along the line. This has been used to improve resolution and statistical accuracy. Resolution is in the range of 3—4 mm and is less dependent on position than is SPECT (16). [Pg.482]

A Siemens Kratky camera system was utilized for small angle x-ray scattering (SAXS) measurements in conjunction with an M. Braun position sensitive detector from Innovative Technology Inc.. Wide angle x-ray diffraction was obtained utilizing a Philips table-top x-ray generator. [Pg.358]

High-purity lead oxide is used to make precision glasses needed for lasers, low-dose X-ray machines, fiber optic probes, medical camera systems, and low-light military equipment such as night vision scopes and goggles. [Pg.387]

Figure 1. A schematic diagram of the streak camera system for laser ablation. Figure 1. A schematic diagram of the streak camera system for laser ablation.
Specific attributes and features of camera systems, lenses, and lighting systems are presented in table 9.11. [Pg.200]

Camera It is important to have the pictures of crystals. Aside from the obvious reason of publication and grant writing, pictures give an on-going record of crystallization conditions and make it easy to see improvements in crystals over time. Cameras can be either film or digital and are usually easily mounted onto most microscopes. Olympus and Nikon offer very good digital camera systems. [Pg.470]

The use of a sensitive camera system, such as a cooled charged-coupled device (CCD) camera, facilitates resolution and recording of the image, including the pseudocolors generated by probes 4-7. [Pg.361]

Camera battery life can be unpredictable A fresh and complete spare set is a necessity rather than a luxury. In many modem 35-mm camera systems, functioning batteries are required for a simple task such as loading film. If the camera is part of a seldom used supply kit, special attention is needed to ensure fresh primary and spare batteries are available and that the film has not passed its expiration date. [Pg.362]

Sapsford etal. (2001) examined microarray-based antibody-antigen binding kinetics in real time to determine the effect of spot size. Capture antibodies were immobilized in an array pattern onto silver-clad microscope slides. Antimouse IgG was directly attached to the surface or attached via neutravidin capture of the biotinylated antibody. Cy5-labeled mouse IgG capture was monitored based upon the signal generated from the excitation of an evanescent wave guide (slide) with a 635-nm laser source detection was achieved by a charge-coupled device (CCD) camera system. Both static and flow-through conditions were employed. [Pg.195]

This is due to the image re-writing propensity of the rotating mirror and many drum-camera systems. Small auxiliary detonating charges can be used in a number of ways to block off light and image exactly when required. [Pg.109]

In field use, the camera system was suspended from a large float and allowed to drift freely. An initial 30-min delay in the timing circuit provided time for deployment of the apparatus before the first exposure, and permitted the movement of the ship downwind at least 0.5 km. Following the delay, photographs were made at 30-sec intervals until the entire roll of film was exposed. Following development, bubble images on the film were measured directly by microscope with the aid of an ocular micrometer (ref. 33). [Pg.29]

Selected specimens from both light and light/water exposure studies were photographed using conventional camera systems for comparative purposes. [Pg.355]

After the appropriate dwell time has elapsed, the sample command is issued and initiates ADC conversion of the elemental intensity. The basic camera system is supplied with an 8-bit ADC, however, to take full advantage of the dynamic range available with the image dissector, an auxiliary signal amplifier/12-bit ADC module was incorporated into the system. [Pg.71]


See other pages where Camera system is mentioned: [Pg.542]    [Pg.545]    [Pg.1027]    [Pg.49]    [Pg.46]    [Pg.401]    [Pg.619]    [Pg.61]    [Pg.98]    [Pg.201]    [Pg.217]    [Pg.282]    [Pg.275]    [Pg.305]    [Pg.132]    [Pg.304]    [Pg.49]    [Pg.462]    [Pg.300]    [Pg.105]    [Pg.113]    [Pg.193]    [Pg.107]    [Pg.425]    [Pg.241]    [Pg.244]    [Pg.527]    [Pg.60]    [Pg.67]    [Pg.70]   
See also in sourсe #XX -- [ Pg.387 ]




SEARCH



Block camera system

Camera

Camera, cameras

Camera-based monitoring systems

Camera-based systems

Camera-vision systems

Charge-Injection devices camera system

Charge-coupled device camera systems

Laser-streak camera system

Streak camera detection system

Streak camera detection, picosecond systems

Streak camera system

Video cameras systems