Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Video camera system

The microscope body (Bausch and Lomb) has a four-objective revolving turret. Flat-field objectives, ranging from 4x to 40x, are used which allow all sections of the visual field to be simultaneously focused. The trinocular body permits the image to be either viewed with lOx wide-field eyepieces or sent to a video camera system. Also, the microscope body contains an analyzing polarizer that can be activated for observation of birefringence in the sample. [Pg.195]

Closely related to the these hydrographical changes are redox-dependent processes. The 1980s is well known for a stagnation period, when saline water inflows and oxygen supply to the deep water were rather sparse. Observations with help of a special sediment video camera system in the central Arkona Basin in 1989 (Rumohr, AMBIO 1990) proved a dramatic oxygen deficiency at the seafloor, occurrence of sulfur bacteria. [Pg.426]

We conclude this subject with some very recent information. In the book accompanying the International Symposium for Planar Chromatography in April 1997 in Interlaken (Switzerland), Prosek indicates the possibility of validating quantitative TLC using a video camera system [120]. In the same Symposium, Ebel made the following points in his lecture on the theme of validation [153] ... [Pg.213]

The classical approach to making video camera systems is based on using CCD imagers. This technique has matured during the last 25 years and CCD users have become accustomed to their limitations in resolution, dynamic range, temperature behavior, and the complex interfacing. [Pg.390]

Mizuno, T., Kawasaki, K. and Miyamoto, H. (1992). Construction of a thermotaxis chamber providing spatial or temporal thermal gradients monitored by an infrared video camera system. Analyt. Biochem. 207, 208—213. [Pg.6]

Video camera systems are available from several manufacturers for documentation and densitometric quantification of TLC plates. As an example, the Camag VideoScan (Fig. 6) consists of the VideoStore documentation system, which includes a lighting module with short- and longwave UV and visible sources upon which the layer is placed, a CCD camera with zoom and long-time... [Pg.1643]

Sostawa, B. MOST Networking Approach for Video-Camera Systems in ADAS, MOST Forum (2014)... [Pg.277]

Sohd tantalum capacitors have a high volumetric capacitance which makes them attractive for use in miniaturized electronic systems like cellular telephones, hand-held video cameras, and personal computers. The insensitivity of their capacitance to temperature and their abiUty to operate at temperature extremes explains why these devices are used in such harsh environments as automobile engine compartments. Sohd tantalum capacitors are extremely rehable and, therefore, are often the capacitor of choice in critical appHcations like spacecraft electronics, pacemakers, and safety equipment. [Pg.330]

To date, the usual way of recording the LEED pattern is a light-sensitive video camera with a suitable image-processing system. In older systems movable Earaday cups (EC) were used which detected the electron current directly. Because of long data acquisition times and the problems of transferring motion into UHV, these systems are mostly out of use nowadays. [Pg.73]

The initial performance test for all local ventilation systems is a smoke test, which provides easy airflow visualization between the source and the hood, it helps to identify, with little effort, the main features of airflow patterns. Such a test, recorded by a video camera, allows performance comparisons to be made before and after improvements. Real contaminant or tracer gas measurements are necessary in the case of more detailed testing. [Pg.1014]

Unlike other infrared techniques, thermal or infrared imaging provides the means to scan the infrared emissions of complete machines, process or equipment in a very short time. Most of the imaging systems function much like a video camera. The user can view the thermal... [Pg.799]

Where such internal inspection work is carried, out a safety checklist and processes for confined space entry permit system and tag-out/lock-out MUST be undertaken before any person enters the boiler. The inspection of waterside surfaces should be carried out by a suitable qualified person and will benefit from employing either an instant camera or a video camera (Horoscope or similar fiberoptic-based device) to record any parts of the boiler where corrective action is needed. [Pg.124]

The use of small electrochromic points allows the construction of monochromic or multichromic flat screens. Using different conducting polymers with complementary colors on ITO-coated flexible plastics (now available commercially), camouflage cloths can be envisaged which, once connected to a video camera and a system of image treatment, would be able to mimic any surrounding, as chameleons or cuttlefish do. [Pg.367]

The basic instrumentation for CL imaging includes an ultrasensitive video camera, an optical system, and appropriate software for image analysis [21],... [Pg.477]


See other pages where Video camera system is mentioned: [Pg.619]    [Pg.282]    [Pg.462]    [Pg.193]    [Pg.213]    [Pg.119]    [Pg.1078]    [Pg.244]    [Pg.1009]    [Pg.769]    [Pg.208]    [Pg.1126]    [Pg.1006]    [Pg.891]    [Pg.231]    [Pg.233]    [Pg.619]    [Pg.282]    [Pg.462]    [Pg.193]    [Pg.213]    [Pg.119]    [Pg.1078]    [Pg.244]    [Pg.1009]    [Pg.769]    [Pg.208]    [Pg.1126]    [Pg.1006]    [Pg.891]    [Pg.231]    [Pg.233]    [Pg.671]    [Pg.1770]    [Pg.229]    [Pg.48]    [Pg.49]    [Pg.428]    [Pg.428]    [Pg.429]    [Pg.390]    [Pg.134]    [Pg.80]    [Pg.371]    [Pg.134]    [Pg.41]    [Pg.17]    [Pg.142]    [Pg.505]    [Pg.160]    [Pg.167]    [Pg.97]   
See also in sourсe #XX -- [ Pg.206 ]




SEARCH



Camera

Camera system

Camera, cameras

Camera, cameras video

Video

© 2024 chempedia.info