Graphite Furnace Atomic Absorption Spectrometry (GFAAS) or Atomic Absorption with Electrothermal Atomisation (ETAAS)... [Pg.252]

Kimbrough and Wakakuwa [276,330] reported on an interlaboratory comparison study involving 160 accredited hazardous materials laboratories. Each laboratory performed a mineral acid digestion on five soils spiked with arsenic, cadmium, molybdenum, selenium and thallium. The instrumental detection methods used were inductively coupled plasma atomic emission spectrometry, inductively coupled plasma mass spectrometry, flame atomic absorption spectrometry, electrothermal atomic absorption spectrometry and hydride generation atomic absorption spectrometry. At most concentrations, the results obtained with inductively coupled plasma atomic emission spectrometry... [Pg.67]

The section on Spectroscopy has been retained but with some revisions and expansion. The section includes ultraviolet-visible spectroscopy, fluorescence, infrared and Raman spectroscopy, and X-ray spectrometry. Detection limits are listed for the elements when using flame emission, flame atomic absorption, electrothermal atomic absorption, argon induction coupled plasma, and flame atomic fluorescence. Nuclear magnetic resonance embraces tables for the nuclear properties of the elements, proton chemical shifts and coupling constants, and similar material for carbon-13, boron-11, nitrogen-15, fluorine-19, silicon-19, and phosphoms-31. [Pg.1284]

Precision For absorbances greater than 0.1-0.2, the relative standard deviation for atomic absorption is 0.3-1% for flame atomization, and 1-5% for electrothermal atomization. The principal limitation is the variation in the concentration of free-analyte atoms resulting from a nonuniform rate of aspiration, nebulization, and atomization in flame atomizers, and the consistency with which the sample is heated during electrothermal atomization. [Pg.422]

The development of methods using sorbents modified with analytical reagents that enable analytical signal measuring directly on the surface by solid-phase spectrometry, visually or by electrothermic atomic absorption spectroscopy (ETAAS) after elution is now a subject of growing interest. [Pg.292]

Electrothermal vaporization can be used for 5-100 )iL sample solution volumes or for small amounts of some solids. A graphite furnace similar to those used for graphite-furnace atomic absorption spectrometry can be used to vaporize the sample. Other devices including boats, ribbons, rods, and filaments, also can be used. The chosen device is heated in a series of steps to temperatures as high as 3000 K to produce a dry vapor and an aerosol, which are transported into the center of the plasma. A transient signal is produced due to matrix and element-dependent volatilization, so the detection system must be capable of time resolution better than 0.25 s. Concentration detection limits are typically 1-2 orders of magnitude better than those obtained via nebulization. Mass detection limits are typically in the range of tens of pg to ng, with a precision of 10% to 15%. [Pg.638]

Tetra-alkyl lead compounds in air Personal monitoring with atomic absorption analysis or electrothermal atomization or X-ray fluorescence spectrometry or on-site colorimetry 9... [Pg.363]

The scope of this review Is limited to electrothermal atomic absorption spectrometry, with emphasis upon Its clinical applications. This article Is Intended to supplement the recent treatises on the basic technique which have been written by Aggett and Sprott ( ) > Ingle ( ), Klrkbrlght (34), Price (63), and Woodrlff (83). This resume does not consider various related topics, such as (a) atomic fluorescence or emission spectrometry (b) non-flame atomization devices which employ direct current... [Pg.248]

Micro-pipetting instruments such as the "Eppendorf or "Oxford pipettors with disposable plastic cone tips are customarily employed to dispense the liquid samples into electrothermal atomizers. Sampling problems which are associated with the use of these pipettors are among the troublesome aspects of electrothermal atomic absorption spectrometry (67,75). The plastic cone-tips are frequently contaminated with metals, and they should invariably be cleaned before use by soaking in dilute "ultra pure nitric acid, followed by multiple rinses with demineralized water which has been distilled in a quartz still. [Pg.254]

Aqueous standard solutions are a source of certain difficulties In electrothermal atomic absorption spectrometry of trace metals In biological fluids The viscosities and surface tensions of aqueous standard solutions are substantially less than the viscosities and surface tensions of serum, blood and other proteln-contalnlng fluids These factors Introduce volumetric disparities In pipetting of standard solutions and body fluids, and also cause differences In penetration of these liquids Into porous graphite tubes or rods Preliminary treatment of porous graphite with xylene may help to minimize the differences of liquid penetration (53,67) A more satisfactory solution of this problem Is preparation of standards In aqueous solutions of metal-free dextran (50-60 g/llter), as first proposed by Pekarek et al ( ) for the standardization of serum chromium analyses This practice has been used successfully by the present author for standardization of analyses of serum nickel The standard solutions which are prepared In aqueous dextran resemble serum In regard to viscosity and surface tension Introduction of dextran-contalnlng standard solutions Is an Important contribution to electrothermal atomic absorption analysis of trace metals In body fluids. [Pg.255]

Acar 0, Kn ic Z, Turker AR (1999) Determination of bismuth, indium and lead in geological and sea-water samples by electrothermal atomic absorption spectrometry with nickel containing chemical modifiers. Anal Chim Acta 382 329-338. [Pg.277]

Aguilera de Benzo Z, Fraile R, Carrion N, et al. 1989. Determination of lead in whole blood by electrothermal atomization atomic absorption spectrometry using tube and platform atomizers and dilution with Triton X-100. Journal of Analytical and Atmospheric Spectrometry 4 397-400. [Pg.484]

Electrothermal atomic absorption spectrophotometry with Zeeman background correction was used by Zhang et al. [141] for the determination of cadmium in seawater. Citric acid was used as an organic matrix modifier and was found to be more effective than EDTA or ascorbic acid. The organic matrix modifier reduced the interferences from salts and other trace metals and gave a linear calibration curve for cadmium at concentrations < 1.6 pg/1. The method has a limit of detection of 0.019 pg/1 of cadmium and recoveries of 95-105% at the 0.2 pg of cadmium level. [Pg.151]

The collection behaviour of chromium species was examined as follows. Seawater (400 ml) spiked with 10-8 M Crm, CrVI, and Crm organic complexes labelled with 51Cr was adjusted to the desired pH by hydrochloric acid or sodium hydroxide. An appropriate amount of hydrated iron (III) or bismuth oxide was added the oxide precipitates were prepared separately and washed thoroughly with distilled water before use [200]. After about 24 h, the samples were filtered on 0.4 pm nucleopore filters. The separated precipitates were dissolved with hydrochloric acid, and the solutions thus obtained were used for /-activity measurements. In the examination of solvent extraction, chromium was measured by using 51Cr, while iron and bismuth were measured by electrothermal atomic absorption spectrometry. The decomposition of organic complexes and other procedures were also examined by electrothermal atomic absorption spectrometry. [Pg.163]

To determine down to 2.4 xmol/l of copper in seawater, Nishoika et al. [282] complexed the copper with di-ethyl-dithio carbamate, precipitated with ferric hydroxide, filtered off and dissolved the precipitate with nitric acid, and determined copper by electrothermal atomic absorption spectrometry. [Pg.171]

In order to overcome the problem of the high nonspecific absorption, alternative procedures have been tested, which involve prior separation of the trace metals from the salt matrix. Examples of extraction of trace metals from seawater as chelates with subsequent determination by electrothermal atomic absorption spectrometric procedures have been described [381,382], but these and similar methods are seldom effective and satisfactory when the matrix is very complex and the analyte concentration very low. [Pg.186]

A typical measurement was performed as follows. The feeder was lowered into the crucible and the sample solution (seawater) was allowed to flow under an inert atmosphere with the suction on. A constant current was applied for a predetermined time. When the pre-electrolysis was over, the flow was changed from the sample to the ammonium acetate washing solution, while the deposited metals were maintained under cathodic protection. Ammonium acetate was selected for its low decomposition temperature, and a 0.2 ml 1 1 concentration was used to ensure sufficient conductivity. At this point the feeder tip was raised to the highest position and the usual steps for an electrothermal atomic absorption spectrometry measurement were followed drying for 30 s at 900 C, ashing for 30 s at 700 °C, and atomization for 8 s at 1700 °C, with measurement at 283.3 nm. The baseline increases smoothly with time as a consequence of an upward lift of the crucible caused by thermal expansion of the material. [Pg.187]

Nishioka et al. [525] coprecipitated nickel from seawater with sodium di-ethyldithiocarbamate, filtered, and redissolved the precipitate with nitric acid followed by electrothermal atomic absorption spectrophotography determination of the nickel. The detection limit was 0.5 p,g/l and the relative standard deviation was 13.2% at the 2 ig/l level. [Pg.208]

Chakraborti et al. [665] determined cadmium, cobalt, copper, iron, nickel, and lead in seawater by chelation with diethyldithiocarbamate from a 500 ml sample, extraction into carbon tetrachloride, evaporation to dryness, and redissolution in nitric acid prior to determination by electrothermal atomic absorption spectrometry in amounts ranging from 10 pg (cadmium) to 250 pg (nickel). [Pg.239]

Chang et al. [952] used a miniature column packed with a chelating resin and an automatic online preconcentration system for electrothermal atomic absorption spectrometry to determine cadmium, cobalt, and nickel in seawater. Detection limits of 0.12,7 and 35 ng/1 were achieved for cadmium, cobalt, and nickel, respectively, with very small sample volume required (400-1800 xl). [Pg.240]


See other pages where Atomic absorption with electrothermal is mentioned: [Pg.60]    [Pg.864]    [Pg.60]    [Pg.864]    [Pg.1561]    [Pg.5061]    [Pg.5062]    [Pg.1]    [Pg.241]    [Pg.1]    [Pg.281]    [Pg.422]    [Pg.39]    [Pg.64]    [Pg.78]    [Pg.105]    [Pg.788]    [Pg.251]    [Pg.251]    [Pg.252]    [Pg.256]    [Pg.257]    [Pg.258]    [Pg.259]    [Pg.259]    [Pg.262]    [Pg.610]    [Pg.164]    [Pg.171]    [Pg.231]   


SEARCH



Atomic absorption with electrothermal atomisation

Atomic electrothermal

Electrothermal

Electrothermal Atomic Absorption Spectrometric Determination of Trace Metals in Sea Water with On-line Sorbent Extraction Separation and Preconcentration

Electrothermal atomic absorption

Electrothermal atomization absorption

Electrothermal atomization atomic absorption

Electrothermal atomizers

Electrothermics

© 2024 chempedia.info