APCI

In essence, solvent ions can transfer a proton to the analyte if the analyte s proton affinity (PA) is higher than that of the eluent molecules, by means of gas-phase reactions. [Pg.159]

In negative ion mode, (M-H) is typically formed by the proton abstraction by OH.  [Pg.159]

APCI sources exhibit mass-dependent sensitivity, that is, the more analyte that enters the source, the greater the signal from that analyte (up to a point), so it is advantageous to allow the full flow into the source. [Pg.159]

The most common secondary cluster ion is (H20)2H , together with significant amounts of (H20)3H and HjO. These charged water clusters collide with the analyte molecules, resulting in the formation of analyte ions  [Pg.6]

APCI is the simultaneous formation of different adduct ions. Depending on eluent composition and matrix components, it is possible that Na and NH4 adducts can occur besides protonated analyte molecules, making the data evaluation more difficult. [Pg.7]


One of the first successful techniques for selectively removing solvent from a solution without losing the dissolved solute was to add the solution dropwise to a moving continuous belt. The drops of solution on the belt were heated sufficiently to evaporate the solvent, and the residual solute on the belt was carried into a normal El (electron ionization) or Cl (chemical ionization) ion source, where it was heated more strongly so that it in turn volatilized and could be ionized. However, the moving-belt system had some mechanical problems and could be temperamental. The more recent, less-mechanical inlets such as electrospray have displaced it. The electrospray inlet should be compared with the atmospheric-pressure chemical ionization (APCI) inlet, which is described in Chapter 9. [Pg.55]

The term nebulizer is used generally as a description for any spraying device, such as the hair spray mentioned above. It is normally applied to any means of forming an aerosol spray in which a volume of liquid is broken into a mist of vapor and small droplets and possibly even solid matter. There is a variety of nebulizer designs for transporting a solution of analyte in droplet form to a plasma torch in ICP/MS and to the inlet/ionization sources used in electrospray and mass spectrometry (ES/MS) and atmospheric-pressure chemical ionization and mass spectrometry (APCI/MS). [Pg.138]

Many designs of nebulizer are commonly used in ICP/MS, but their construction and mode of operation can be collated into a small number of groups pneumatic, ultrasonic, thermospray, APCI, and electrospray. These different types are discussed in the following sections, which are followed by further sections on spray and desolvation chambers. [Pg.139]

Nebulizers are used to introduce analyte solutions as an aerosol spray into a mass spectrometer. For use with plasma torches, it is necessary to produce a fine spray and to remove as much solvent as possible before the aerosol reaches the flame of the torch. Various designs of nebulizer are available, but most work on the principle of interacting gas and liquid streams or the use of ultrasonic devices to cause droplet formation. For nebulization applications in thermospray, APCI, and electrospray, see Chapters 8 and 11. [Pg.152]

The hybrid can be used with El, Cl, FI, FD, LSIMS, APCI, ES, and MALDI ionization/inlet systems. The nature of the hybrid leads to high sensitivity in both MS and MS/MS modes, and there is rapid switching between the two. The combination is particularly useful for biochemical and environmental analyses because of its high sensitivity and the ease of obtaining MS/MS structural information from very small amounts of material. The structural information can be controlled by operating the gas cell at high or low collision energies. [Pg.161]

The LC/TOF instmment was designed specifically for use with the effluent flowing from LC columns, but it can be used also with static solutions. The initial problem with either of these inlets revolves around how to remove the solvent without affecting the substrate (solute) dissolved in it. Without this step, upon ionization, the large excess of ionized solvent molecules would make it difficult if not impossible to observe ions due only to the substrate. Combined inlet/ionization systems are ideal for this purpose. For example, dynamic fast-atom bombardment (FAB), plas-maspray, thermospray, atmospheric-pressure chemical ionization (APCI), and electrospray (ES)... [Pg.163]

By being able to obtain an unequivocal relative molecular mass, or even a molecular formula derived from that mass, the hybrid mass spectrometer becomes a powerful tool for investigating single substances or mixtures of substances. With an APCI inlet, fragmentation can be induced to obtain structural information (see Chapter 9). [Pg.167]

In one instrument, ions produced from an atmospheric-pressure ion source can be measured. If these are molecular ions, their relative molecular mass is obtained and often their elemental compositions. Fragment ions can be produced by suitable operation of an APCI inlet to obtain a full mass spectrum for each eluting substrate. The system can be used with the effluent from an LC column or with a solution from a static solution supply. When used with an LC column, any detectors generally used with the LC instrument itself can still be included, as with a UV/visible diode array detector sited in front of the mass spectrometer inlet. [Pg.167]

To achieve sufficient vapor pressure for El and Cl, a nonvolatile liquid will have to be heated strongly, but this heating may lead to its thermal degradation. If thermal instability is a problem, then inlet/ionization systems need to be considered, since these do not require prevolatilization of the sample before mass spectrometric analysis. This problem has led to the development of inlet/ionization systems that can operate at atmospheric pressure and ambient temperatures. Successive developments have led to the introduction of techniques such as fast-atom bombardment (FAB), fast-ion bombardment (FIB), dynamic FAB, thermospray, plasmaspray, electrospray, and APCI. Only the last two techniques are in common use. Further aspects of liquids in their role as solvents for samples are considered below. [Pg.279]

For solids, there is now a very wide range of inlet and ionization opportunities, so most types of solids can be examined, either neat or in solution. However, the inlet/ionization methods are often not simply interchangeable, even if they use the same mass analyzer. Thus a direct-insertion probe will normally be used with El or Cl (and desorption chemical ionization, DCl) methods of ionization. An LC is used with ES or APCI for solutions, and nebulizers can be used with plasma torches for other solutions. MALDI or laser ablation are used for direct analysis of solids. [Pg.280]

El = electron ionization Cl = chemical ionization ES = electrospray APCI = atmospheric-pressure chemical ionization MALDI = matrix-assisted laser desorption ionization PT = plasma torch (isotope ratios) TI = thermal (surface) ionization (isotope ratios). [Pg.280]

When mass spectrometry was first used as a routine analytical tool, El was the only commercial ion source. As needs have increased, more ionization methods have appeared. Many different types of ionization source have been described, and several of these have been produced commercially. The present situation is such that there is now only a limited range of ion sources. For vacuum ion sources, El is still widely used, frequently in conjunction with Cl. For atmospheric pressure ion sources, the most frequently used are ES, APCI, MALDI (lasers), and plasma torches. [Pg.282]

Electrospray Ionization (ES) and Atmospheric Pressure Chemical Ionization (APCI)... [Pg.283]

Apart from ES and APCI being excellent ion sources/inlet systems for polar, thermally unstable, high-molecular-mass substances eluting from an LC or a CE column, they can also be used for stand-alone solutions of substances of high to low molecular mass. In these cases, a solution of the sample substance is placed in a short length of capillary tubing and is then sprayed from there into the mass spectrometer. [Pg.284]

Intact peptides and proteins can be examined by a variety of new techniques, including MS/MS, dynamic FAB, APCI, and electrospray. Large masses of tens of thousands of Daltons can be accurately measured with unprecedented accuracy by electrospray. [Pg.294]

Thus, either the emitted light or the ions formed can be used to examine samples. For example, the mass spectrometric ionization technique of atmospheric-pressure chemical ionization (APCI) utilizes a corona discharge to enhance the number of ions formed. Carbon arc discharges have been used to generate ions of otherwise analytically intractable inorganic substances, with the ions being examined by mass spectrometry. [Pg.388]

Samples containing mixtures of peptides can be analyzed directly by electrospray. Alternatively, the peptides can be separated and analyzed by LC/MS coupling techniques such as electrospray or atmospheric pressure chemical ionization (APCI). [Pg.417]

III) East LC-APCI-MS/MS analysis using a short luonolitliie separation eoluiun eoupled to a triple-quadiupole luass speetroiueter operating in luultiple reaetion luonitoring (MRM) detention luode. [Pg.11]

A liquid chromatography-mass spectrometry (LC-MS) method that can quantitatively analyze urinar y normal and modified nucleosides in less than 30 min with a good resolution and sufficient sensitivity has been developed. Nineteen kinds of normal and modified nucleosides were determined in urine samples from 10 healthy persons and 18 breast cancer patients. Compounds were separ ated on a reverse phase Kromasil C18 column (2.1 mm I.D.) by isocratic elution mode using 20 mg/1 ammonium acetate - acetonitrile (97 3 % v/v) at 200 p.l/min. A higher sensitivity was obtained in positive atmospheric pressure chemical ionization mode APCI(-i-). [Pg.351]

Phone +1 610 481 4911 Fax -K 610 481 5900 E-mail info apci.com Web site www.aii-products.com Stock listing NYSE APD... [Pg.215]

An on-line chromatography/atmospheric pressure chemical ionization tandem mass spectrometry (LC-APCI/MS/MS) methods was developed for rapid screen of pharmacokinetics of different drugs, including 5 (98RCM1216). The electron impact mass spectrum of 5 and ethyl 9,10-difluoro-3-methyl-7-oxo-2,3-dihydro-7Ff-pyrido[l,2,3- fe]-l,4-benzoxazine-6-carboxylate was reported (97MI28). Electron impact/Fourier transform... [Pg.268]

Atmospheric pressure chemical ionization (APCI) Chemical ionization at atmospheric pressure. [Pg.372]

The pump must provide stable flow rates from between 10 ttlmin and 2 mlmin with the LC-MS requirement dependent upon the interface being used and the diameter of the HPLC column. For example, the electrospray interface, when used with a microbore HPLC column, operates at the bottom end of this range, while with a conventional 4.6 mm column such an interface usually operates towards the top end of the range, as does the atmospheric-pressure chemical ionization (APCI) interface. The flow rate requirements of the different interfaces are discussed in the appropriate section of Chapter 4. [Pg.27]

Ionization methods that may be utihzed in LC-MS include electron ionization (El), chemical ionization (Cl), fast-atom bombardment (FAB), thermospray (TSP), electrospray (ESI) and atmospheric-pressure chemical ionization (APCI). [Pg.52]

TSP, ESI and APCI effect ionization from solution and in these cases it is not possible to separate a description of the processes involved in the ionization of an analyte from a description of the interface. These ionization techniques will therefore be described in detail in Chapter 4. [Pg.52]

For many years, electron ionization, then more usually known as electron impact, was the only ionization method used in analytical mass spectrometry and the spectra encountered showed exclusively the positively charged species produced during this process. Electron ionization also produces negatively charged ions although these are not usually of interest as they have almost no structural significance. Other ionization techniques, such as Cl, FAB, thermospray, electrospray and APCI, however, can be made to yield negative ions which are of analytical utility. [Pg.56]

In summary, it can be said that prior to the development of the thermospray interface there were an increasing nnmber of reports of the analytical application of LC-MS [3] bnt in this present anthor s opinion, based on a nnmber of years of using a moving-belt interface, the technique could not be considered to be routine . The thermospray interface changed this and with the commercial intro-dnction of the combined APCI/electrospray systems in the 1990s the technique, for it now may be considered as a true hybrid technique, has reached maturity (although this should not be taken as a suggestion that there will be no further developments). [Pg.135]

Atmospheric-pressure chemical ionization (APCI) is another of the techniques in which the stream of liquid emerging from an HPLC column is dispersed into small droplets, in this case by the combination of heat and a nebulizing gas, as shown in Figure 4.21. As such, APCI shares many common features with ESI and thermospray which have been discussed previously. The differences between the techniques are the methods used for droplet generation and the mechanism of subsequent ion formation. These differences affect the analytical capabilities, in particular the range of polarity of analyte which may be ionized and the liquid flow rates that may be accommodated. [Pg.180]


See other pages where APCI is mentioned: [Pg.38]    [Pg.60]    [Pg.71]    [Pg.73]    [Pg.163]    [Pg.277]    [Pg.280]    [Pg.283]    [Pg.283]    [Pg.284]    [Pg.284]    [Pg.285]    [Pg.248]    [Pg.218]    [Pg.215]    [Pg.14]   


SEARCH



APCI (atmospheric-pressure chemical

APCI biodegradation

APCI biodegradation products

APCI biological fluids

APCI capillary zone electrophoresis

APCI carbamates

APCI coupling

APCI drugs

APCI explosives

APCI fruits

APCI fungicides

APCI general

APCI groundwater

APCI herbicides

APCI interface

APCI metabolites

APCI natural waters

APCI or APPI

APCI organophosphorus

APCI pesticides

APCI pharmaceuticals

APCI phenolic compounds

APCI phenols

APCI phenylureas

APCI polycyclic aromatic hydrocarbons

APCI process

APCI quantification

APCI review

APCI river water

APCI rivers

APCI sediment

APCI spectra

APCI sulfonic acids

APCI sulfonylureas

APCI surface water

APCI surfactants

APCI triazines

APCI vegetables

APCI water

APCI-MS (

Achievements APCI)

Atmosphere pressure chemical ionization APCI)

Atmospheric pressure APCI)

Atmospheric pressure chemical ionisation APCI)

Atmospheric-pressure chemical ionization APCI)

Current Trends for APCI

EC-APCI

Electrospray ionization and APCI

Food analysis APCI interface

HPLC-APCI

High-performance liquid spectrometry (HPLC-APCI

Ion Sources for APCI

Ionization techniques APCI)

LC-APCI

Mass spectrometry APCI)

Nano APCI

SPE-LC-APCI

The Choice of Electrospray or APCI

Typical Reaction Sequence for An APCI Source (Somewhat Simplified) Is