Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Ancillary Data Requirements

Ancillary Data Requirements.—Accurately known vapour pressures are required in this work. For many compounds these are known and good compilations are available. If reliable data are not available, very pure samples must be obtained in order to measure the vapour pressures. A review of the various methods available has recently been published. Accurate measurements are required because of the sensitivity of the value determined for an activity coefficient to the value assumed for the vapour pressure. An error of 30 Pa in a vapour pressure of 30kPa will result in an error of 0.1 per cent in activity coefficient. [Pg.60]

Solute densities and the second virial coefficients of carrier gases and solutes are also required. These properties need not be known to the same order of accuracy as the vapour pressures. Good compilations are available for both densities and second virial coefficients. If they are not available, approximations can be made by a comparison with similar compounds. [Pg.60]


When the structure becomes valid, the system attaches salt to the parent structure and the compound transitions to Salt Attached State. At this point, if the chemist edits the structure, the system has to decompose the structure into fragments again and the whole structure process will start over. Otherwise, the system makes sure all required ancillary data are entered and the compound enters the Ready for Registration State. The final state of die compound is Registered State—compound stored in the database. [Pg.76]

The last state of a compound in the compound registration context is Ready To Be Registered State. A compound is ready for registration when its structure passes chemistry convention rules and salts have been attached, and all required ancillary data, such as project and notebook information, have been entered. [Pg.81]

When all ChemicalSample objects are in the Ready To Be Registered State and all required ancillary data are entered, the user can submit the Chemical Samples for registration. The ApplicationController returns a Registration Command object to the FrontController. The FrontController invokes the... [Pg.137]

The statistical nature of the turbulent flame required the analysis of many temperature and density data points from separate pulses for accurate results. Thus, an overall computer system was used to control the various components of the combustion probe apparatus, and to collect and interpret the resultant data in an accurate and timely fashion. This system produced a block of data for each laser shot that included information about the Raman signals, LV readings, and ancillary data such as an identifying shot number and corresponding dye laser pulse energy. Typical current operation permits about twenty experimental run conditions daily, with up to several hundred shots per run. [Pg.240]

Current systems require many steps to include graphical objects and other non-textual entities into documents. The new systems will support easy incorporation of multiple data types (e.g., chemical structures, reaction schemes, graphs, charts, data tables, etc.) while retaining the characteristics of the objects. One will be able to manipulate the object in its native mode and append ancillary data to the document if desired. [Pg.18]

Chemdata Enhancements. In most Instances when a substructure search Is requested, ancillary data Is also required, most notably biological. The original CSIS design required the printing of every structure retrieved from a search regardless of other search criteria. In order to accommodate all search criteria and yet optimize the utility of search reports, several programs were developed which basically provide a print option. This option Is Invoked at the completion of CSIS searches. In effect, the option Is used to restrict the chemical answers printed from a CSIS search to those with or without biological data and/or with or without sample repository data. [Pg.100]

Computer-aided interpretation of analytical sedimentation data for proteins has been discussed in detail by Laue et al. [92L1]. Of course, a full interpretation of data requires knowledge of ancillary information such as specific volume of the protein, solvent density and viscosity. [Pg.131]

Another major difference between the use of X rays and neutrons used as solid state probes is the difference in their penetration depths. This is illustrated by the thickness of materials required to reduce the intensity of a beam by 50%. For an aluminum absorber and wavelengths of about 1.5 A (a common laboratory X-ray wavelength), the figures are 0.02 mm for X rays and 55 mm for neutrons. An obvious consequence of the difference in absorbance is the depth of analysis of bulk materials. X-ray diffraction analysis of materials thicker than 20—50 pm will yield results that are severely surface weighted unless special conditions are employed, whereas internal characteristics of physically large pieces are routinely probed with neutrons. The greater penetration of neutrons also allows one to use thick ancillary devices, such as furnaces or pressure cells, without seriously affecting the quality of diffraction data. Thick-walled devices will absorb most of the X-ray flux, while neutron fluxes hardly will be affected. For this reason, neutron diffraction is better suited than X-ray diffraction for in-situ studies. [Pg.651]

These considerations require an expanded scope for a monitoring program, involving measurements of ancillary environmental conditions in addition to mercuiy data if the objective is not just to document changes in mercuiy concentrations, but also to gain insight into links between emissions and concentration trends in biota. These issues are addressed in each chapter. [Pg.9]

For reasons discussed above, we needed a complementary, ancillary tool for comparison of the mass spectra of components from multiple urine samples. We desired that the procedure have several characteristics (1) requires little if any manual data entry by the operator (2) utilizes data automatically generated by ChemStation and organized into Microsoft Excel spreadsheets (3) displays both retention times and mass spectral data in the same window (4) minimizes subjective operator judgments and (5) is simple and rapid to use. What emerged after several iterative improvements are the FindPeak macros discussed below. These are largely due to the expertise of Y. Aubut, with valuable input from J. Eggert. [Pg.30]

Such behavior is more common than the full rate/pH profile of (1.207). Equation (1.208) is observed in acid catalysisand (1.209) in base catalysis. The rate constant for the reaction of only one of the two forms can be obtained directly, that is, in (1.208) and in (1.209). Ancillary information on is required to assess the rate constant of the acid-base partner. The absence of reliable data on A jj can pose a problem in assessing the missing rate constant. [Pg.43]

Therefore, thermodynamics plays a fundamental role in supramolecular chemistry. However, thermodynamics is rigorous and as such, a great deal of ancillary information is required prior to the formulation of an equation representative of the process taking place in solution, such as, the composition of the complex and the nature of the speciation in solution. For the latter and when electrolytes are involved, knowledge of the ion-pair formation of the free and complex salts in the appropriate solvent is required particularly in non-aqueous solvents. This information would allow the establishment of the concentrations at which particular ions are the predominant species in solution. Similar considerations must be taken into account when neutral receptors are involved, given that in dipolar aprotic or inert solvents, monomeric species are not always predominant in solution. In addition, awareness of the scope and limitations of the methodology used for the derivation of thermodynamic data for the complexation process is needed and this aspect has been addressed elsewhere [18]. [Pg.86]

Large Data Sets. We have discussed data acquisition problems that must be addressed, but we have not yet considered the question of managing the resultant data. The use of automated aerosol monitors and ancillary instruments will result in massive quantities of data. A typical 4-week experiment in which 10 parameters are monitored at 10-min intervals would require about 0.25 Mbytes of storage. The problems of data storage, organization, and retrieval are likely to be comparable to or greater than the difficulties of data analysis. [Pg.71]

With such a drying suite, users can process their experimental data. They can select an appropriate dryer or get the appropriate dryers recommended after material characteristics (such as moister contents, particle distributions, and experimental drying curves), and product requirements (such as final moisture content, product quality requirements) are specified. They then can perform relevant heat/ mass/pressure balance calculations for not only the dryer(s) but also the ancillary unit operations of the drying operation. Users should be able to further carry out scoping, on... [Pg.1210]

Modern mass spectrometers and ancillary analytical instrumentation require ever-decreasing amounts of test samples to provide analytical data with acceptably low... [Pg.452]

The use of retention data for identification is useful in those cases where the chemical type of the sample is known and when there are a number of pure compounds of this type available for the determination of reference date. However, more often than not, in complex mixtures there are several possible interpretations for each peak and so the agreement between the retention characteristics of a known standard and any component can never be regarded as conclusive evidence of identification. To remove this ambiguity, use of an ancillary technique for identification of components is required. The ancillary technique most used in modem Instruments is mass spectrometry. This type has become so popular that directly coupled gas chromatography - mass spectrometry (GC-MS) units have become the nomi of the day. [Pg.375]

A medical history, physical examination, PFTs, and HRCT should be performed on all patients with suspected DPLD. In many cases, this will provide sufficient data for a diagnosis. In others, the diHerential diagnosis will require additional ancillary testing. The most common of these procedures are bronchoscopy, serologies, and surgical lung biopsy. [Pg.8]


See other pages where Ancillary Data Requirements is mentioned: [Pg.67]    [Pg.87]    [Pg.294]    [Pg.300]    [Pg.317]    [Pg.93]    [Pg.148]    [Pg.390]    [Pg.1732]    [Pg.17]    [Pg.112]    [Pg.338]    [Pg.320]    [Pg.306]    [Pg.185]    [Pg.61]    [Pg.21]    [Pg.63]    [Pg.268]    [Pg.124]    [Pg.279]    [Pg.1442]    [Pg.470]    [Pg.341]    [Pg.65]    [Pg.168]    [Pg.338]    [Pg.82]    [Pg.310]    [Pg.251]    [Pg.155]    [Pg.1277]   


SEARCH



Ancillaries

Ancillary data

Data requirements

© 2024 chempedia.info