Absorption automated

Chemical Properties. Elemental analysis, impurity content, and stoichiometry are determined by chemical or iastmmental analysis. The use of iastmmental analytical methods (qv) is increasing because these ate usually faster, can be automated, and can be used to determine very small concentrations of elements (see Trace AND RESIDUE ANALYSIS). Atomic absorption spectroscopy and x-ray fluorescence methods are the most useful iastmmental techniques ia determining chemical compositions of inorganic pigments. Chemical analysis of principal components is carried out to determine pigment stoichiometry. Analysis of trace elements is important. The presence of undesirable elements, such as heavy metals, even in small amounts, can make the pigment unusable for environmental reasons. [Pg.4]

Since 1970, new analytical techniques, eg, ion chromatography, have been developed, and others, eg, atomic absorption and emission, have been improved (1—5). Detection limits for many chemicals have been dramatically lowered. Many wet chemical methods have been automated and are controlled by microprocessors which allow greater data output in a shorter time. Perhaps the best known continuous-flow analy2er for water analysis is the Autoanaly2er system manufactured by Technicon Instmments Corp. (Tarrytown, N.Y.) (6). Isolation of samples is maintained by pumping air bubbles into the flow line. Recently, flow-injection analysis has also become popular, and a theoretical comparison of it with the segmented flow analy2er has been made (7—9). [Pg.230]

Measurement over long view path (up to 100 km) with suitable illumination and target, contrast transmittance, total extinction, and chromaticity over sight path can be determined includes scattering and absorption from all sources can detect plume blight automated... [Pg.210]

Figure 14-9 also shows a flowchart for analysis of wet and dry precipitation. The process involves weight determinations, followed by pH and conductivity measurements, and finally chemical analysis for anions and cations. The pH measurements are made with a well-calibrated pH meter, with extreme care taken to avoid contaminating the sample. The metal ions Ca, Mg, Na, and are determined by flame photometry, which involves absorption of radiation by metal ions in a hot flame. Ammorda and the anions Cl, S04 , NO3 , and P04 are measured by automated colorimetric techniques. [Pg.213]

The methods dependent upon measurement of an electrical property, and those based upon determination of the extent to which radiation is absorbed or upon assessment of the intensity of emitted radiation, all require the use of a suitable instrument, e.g. polarograph, spectrophotometer, etc., and in consequence such methods are referred to as instrumental methods . Instrumental methods are usually much faster than purely chemical procedures, they are normally applicable at concentrations far too small to be amenable to determination by classical methods, and they find wide application in industry. In most cases a microcomputer can be interfaced to the instrument so that absorption curves, polarograms, titration curves, etc., can be plotted automatically, and in fact, by the incorporation of appropriate servo-mechanisms, the whole analytical process may, in suitable cases, be completely automated. [Pg.8]

In more sophisticated instruments, the modern tendency is to replace the micro-ammeter by a digital read-out, and there is an increasing trend to use visual display units to show the results. Such instruments are controlled by microprocessors which may either show sequentially the successive operations which must be performed to measure the absorbance of a solution at a fixed wavelength or to observe the absorption spectrum of a sample alternatively the whole procedure may be automated. Such instruments will display the absorption spectrum on the VDU screen, and by linking to a printer, a permanent record is produced. [Pg.666]

At present, calcium and magnesium are estimated almost exclusively by atomic absorption (36). Present instrumentation permits the dilution of the specimen to approximately 1 - 100 for calcium and even higher for magnesium. For many instruments, the two elements are not read out simultaneously such as is practicable for sodium and potassium with the flame photometer. The lower limit of serum volime at present, for the practical assay for calciim and magnesiim in the laboratory of Neonatology, is approximately 10 ul The instruments are very readily automated, and it is not uncommon for results to be available at the rate of 240 per hour in the routine laboratory, where a typical atomic absorption instrument such as a Perkin-Elmer has been attached to an automatic feed system. [Pg.129]

Sarbeck, J. R. and Landgraf, W. C. "Automated Peak Discrimination and Integration for Nonflame Atomic Absorption Analysis at Nanogram Levels". J. Pharm. Scl (1974), 63, 929-930. [Pg.269]

Thin film nanostructures of the III-VI compound In2Se3 were obtained inside the pores (200 nm) of commercial polycarbonate membrane by automated ECALE methodology at room temperature [157], Buffered solutions with millimolar concentrations of In2(S04)3 (pH 3.0) and Se02 (pH 5.5) were used. The atomic ratio of Se/In in the deposited films was found to be 3/2. Band gaps from FTIR reflection absorption measurements were found to be 1.73 eV. AFM imaging showed that the deposits consist of 100 nm crystallites. [Pg.194]

Tam et al. [37-47] developed an impressive generalized method for the determination of ionization constants and molar absorptivity curves of individual species, using diode-array UV spectrophotometry, coupled to an automated pH titrator. Species selection was effected by target factor analysis. Multiprotic compounds with overlapping pK s have been investigated binary mixtures of ionizable compounds have been considered assessment of inicroconstants have been reported. [Pg.62]

In the current era many medicinal chemists are unaware of the very important role of compound soUd state properties on aqueous solubility and therefore to oral absorption. In many organizations compound purification by crystallization has disappeared being replaced by automated reverse-phase HPLC purification. If medicinal chemists isolate a compound as a white powder from evaporation of... [Pg.270]

Magnesium deficiency has been long recognized, but hypermagnesia also occurs (Anderson and Talcott 1994). Magnesium can be determined in fluids by FAAS, inductively coupled plasma atomic emission spectrometry (ICP-AES) and ICP-MS. In tissue Mg can be determined directly by solid sampling atomic absorption spectrometry (SS-AAS) (Herber 1994a). Both Ca and Mg in plasma/serum are routinely determined by photometry in automated analyzers. [Pg.202]

Materials Characterization. Regarding education in the characterization or analysis of materials—a central topic of materials chemistry—there is a similar hierarchy of importance of subjects that chemistry students (and faculty) will need to have learned. Reference 7 treats this topic systematically, and Roy and Newnham (11) presented a comprehensive (albeit somewhat outdated) presentation of the architecture of materials characterization. Thus Rutherford backscattering and extended X-ray absorption fine structure (EXAFS) are excellent characterization research tools, but in the sequence of tools used every day on every sample, they are insignificant. Thus for structural characterization, X-ray powder diffraction reigns supreme, yet the full power of the modern automated search routines that can be universally applied are taught only to a minuscule fraction of even the materials science student body. [Pg.61]

The preferred route of administration is intraperitoneal (IP) rather than IV to achieve maximum concentrations at the site of infection. Antibiotics can be administered IP intermittently as a single large dose in one exchange per day or continuously as multiple smaller doses with each exchange. Intermittent administration requires at least 6 hours of dwell time in the peritoneal cavity to allow for adequate systemic absorption and provides adequate levels to cover the 24-hour period. However, continuous administration is better suited for PD modalities that require more frequent exchanges (less than 6-hour dwell time). The reader should refer to the ISPD guidelines for dosing recommendations for IP antibiotics in CAPD and automated PD patients.49 The dose of the antibiotics should be increased by 25% for patients with residual renal function who are able to produce more than 100 mL urine output per day. [Pg.399]

The transfer of an automated analysis from the laboratory to the plant will often require special precautions for instance, while turbidities in a process stream can cause a loss of selective absorptivity in a spectrophotometric measurement, in potentiometric methods fouling of the electrodes, potential leakage in metal containers or tubing and loss of signal in remote control may occur (see later). [Pg.327]

Method 2-Automated method test for lead in gasoline by atomic absorption spectrometry ... [Pg.470]

Langer, K. Frentrup, K.R. Automated-Microscope-Absorption-Spectrophotometry of Rock-Forming Minerals in the Range 250-2000 nm, J. Microscopy. 1979, 116, 311-320. [Pg.167]

Very few published data exist on the evaluation of automated systems, though one report has been made of an automated absorption assay using Caco-2 cells cultured on both sides of polycarbonate membranes [93], The concept of culturing cells on the lower sides of the membranes was investigated as a means of improving the opportunity to study transport in the secretory basolateral to apical direction. However, this approach resulted in increased variability and impaired active transport properties of the cell monolayers, and was therefore not recommended. [Pg.103]

N., Sjostrom, B., Automated absorption assessment using Caco-2 cells cultivated on both sides of polycarbonate membranes, Pharm. [Pg.125]

As previously discussed, compound form differs markedly between early discovery and the late discovery/development interface. The early discovery compound is poorly characterized as to its crystalline form - it may be nonsolid, amorphous, or possibly crystalline but uncharacterized as to polymorphic form. The late discovery/development interface compound is crystalline as defined by phase-contract microscopy or powder X-ray diffraction, and its polymorphic and salt form is frequently characterized. This difference has profound implications for the design of a discovery solubility assay. The key question is this Is it better to design an early discovery solubility assay as a separate type of experiment, or is it better to try to automate a traditional thermodynamic solubility assay to handle the very large number of compounds likely to be encountered in early discovery Another way to state this question is this Does it make sense to run a thermodynamic solubility assay on poorly crystalline early discovery compounds This is the type of question about which reasonable people could disagree. However, this author does have a distinct opinion. It is much better to set up a distinctively different solubility assay in early discovery and to maintain a clear distinction between the assay type appropriate in early discovery and the assay type appropriate at the late discovery/ development interface. Two issues are relevant to this opinion One relates to the need for a solubility assay to reflect/predict early discovery stage oral absorption and the other relates to people/chemistry issues. [Pg.228]

It has been reported that the differential determination of arsenic [36-41] and also antimony [42,43] is possible by hydride generation-atomic absorption spectrophotometry. The HGA-AS is a simple and sensitive method for the determination of elements which form gaseous hydrides [35,44-47] and mg/1 levels of these elements can be determined with high precision by this method. This technique has also been applied to analyses of various samples, utilising automated methods [48-50] and combining various kinds of detection methods, such as gas chromatography [51], atomic fluorescence spectrometry [52,53], and inductively coupled plasma emission spectrometry [47]. [Pg.339]

Agemian and Chau [55] have described an automated method for the determination of total dissolved mercury in fresh and saline waters by ultraviolet digestion and cold vapour atomic absorption spectroscopy. A flow-through ultraviolet digester is used to carry out photo-oxidation in the automated cold vapour atomic absorption spectrometric system. This removes the chloride interference. Work was carried out to check the ability of the technique to degrade seven particular organomercury compounds. The precision of the method at levels of 0.07 pg/1, 0.28 pg/1, and 0.55 pg/1 Hg was 6.0%, 3.8%, and 1.00%, respectively. The detection limit of the system is 0.02 pg/1. [Pg.463]

The principles and applications of atomic absorption spectroscopy to clinical and biological analysis have been reviewed by several authors 279-286) and automation in the analysis has been reviewed 28 ). [Pg.106]


See other pages where Absorption automated is mentioned: [Pg.516]    [Pg.441]    [Pg.509]    [Pg.404]    [Pg.405]    [Pg.405]    [Pg.548]    [Pg.417]    [Pg.254]    [Pg.185]    [Pg.53]    [Pg.1]    [Pg.437]    [Pg.254]    [Pg.256]    [Pg.263]    [Pg.112]    [Pg.805]    [Pg.131]    [Pg.136]    [Pg.156]    [Pg.157]    [Pg.75]    [Pg.229]    [Pg.361]    [Pg.141]    [Pg.20]   
See also in sourсe #XX -- [ Pg.808 , Pg.811 ]