Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Search Routine

This information is provided for the convenience of the reader who wishes to pursue the subject further but will not be utilized in this book. [Pg.305]

Of the two methods that are actually most often used in practice, one is a systematic search and the other is a stochastic search, although others, and numerous variants, exist.  [Pg.305]

The systematic search is very straightforward in principle. In the following discussion, we will consider molecules that contain only sp hybrid bonding (saturated molecules). One can easily see how to extend this to other cases. [Pg.306]

But the two methyl groups here are much too close together, and there is a large van der Waals repulsion between them. While the molecule could deform in different [Pg.306]


Various search routines determine necessary points automatically the location of the entrance into the container... [Pg.869]

Once a mass spectrum from an eluting component has been acquired, the next step is to try to identify the component either through the skill of the mass spectroscopist or by resorting to a library search. Most modem GC/MS systems with an attached data station include a large library of spectra from known compounds (e.g., the NIST library). There may be as many as 50,000 to 60,000 stored spectra covering most of the known simple volatile compounds likely to be met in analytical work. Using special search routines under the control of the computer, one can examine... [Pg.257]

The mass spectra of drugs are as varied as the molecules from which they are formed (see Table 11.1). Two major sources that are available for identifying drugs are computer library search routines and Mass Spectral and GC Data of Drugs, Poisons and Their Metabolites. ... [Pg.251]

The first interactive electronic encyclopedia for users of plastics, materials selection is carried out using 3 search routines. The Chemical Resistance Search eliminates materials that cannot meet user specified chemical resistance requirements. The other search routines ( Elimination and Combined Weighting ) eliminate candidate materials based on 72 properties, falling within one of the following groups General and Electrical, Mechanical, Cost Factors, Production Methods and Post Processing. All data is evaluated and based on independent tests conducted in RAPRA s laboratories. [Pg.596]

In each of these situations It Is possible to list the appropriate literature reference The search procedure has been designed In an Interactive mode so that even an Individual who has never used It may obtain an explanation for a particular problem, but the experienced searcher can by-pass the longer Interactive search routine This mode of operation Is In use only at the National Institutes of Health and a simpler procedure Is used In Evanston Hospital ... [Pg.282]

Materials Characterization. Regarding education in the characterization or analysis of materials—a central topic of materials chemistry—there is a similar hierarchy of importance of subjects that chemistry students (and faculty) will need to have learned. Reference 7 treats this topic systematically, and Roy and Newnham (11) presented a comprehensive (albeit somewhat outdated) presentation of the architecture of materials characterization. Thus Rutherford backscattering and extended X-ray absorption fine structure (EXAFS) are excellent characterization research tools, but in the sequence of tools used every day on every sample, they are insignificant. Thus for structural characterization, X-ray powder diffraction reigns supreme, yet the full power of the modern automated search routines that can be universally applied are taught only to a minuscule fraction of even the materials science student body. [Pg.61]

The quantity slope2 is the slope of the line search objective function gk(a) at a = ak (see Figure 6.8) and slopel is its slope at a = 0, so (dk)Tyk > 0 if and only if slope2 > slopel. This condition is always satisfied if /is strictly convex. A good line search routine attempts to meet this condition if it is not met, then H is not updated. [Pg.208]

With regard to computer programming, the optimum seeking methods should be written separately and stored as a library program for repetitive use. The main program reads the input data, calls the search routine, performs any noniterative calculations, and handles the output. The calculation of iterative state variables and the calculation of the objective function should be performed within function subprograms. [Pg.101]

Using a search routine, a computer program can calculate the constants and C2 from definitions of the moments of the distribution ... [Pg.74]

The Rosenbrock search routine in the computer program employed by Balke and Hamielec was found to converge to the correct optimum values of Cl and C2 within approximately 200 iterations. [Pg.75]

In a binary diagram the position of the three-phase line can be calculated utilising a method whereby the step size is changed when a phase boundary is reached. For example, the calculation begins with an alloy in the (a 4- 0) phase held. The temperature is increased by 10°C steps and its composition maintained so that it exists in the (a + 0) phase field. At each new step the stability of the liquid is checked. Once the liquid becomes stable the previous temperature is used as a start point and the temperature step is decreased. This process is repeated with subsequent decreased step sizes until a the temperature is defined within a critical step size. This method is cumbersome and more intelligent searching routines can be used. But in the end the temperature will be defined within a critical step size. Alternatively, the temperature where the activity/chemical potential of A and B in the three phases is equal can be explicitly calculated. [Pg.296]

The discussion above centred around diagrams where die axes were composition or temperature. It is quite possible to use other variables in mapping routines, for example, activity/chemical potential and pressure. Furdier, it is possible to consider mapping other features, for example, the liquid invariant lines in a ternary system (Fig. 9.21). In such cases the positions of the lines are defined by other criteria than described above and new search routines are required. [Pg.297]

The aids to chromatography include a) resolution calculations on chromatograms of standard mixtures to monitor column performance, b) calculation of Kovats retention index for help in identifying peaks, and (c) multiple point calibration curves for improved quantitation. The file searching routines access two sets of data. Information (such as molecular formula, molecular weight) is stored on 3100 compounds from the Arctander data( ). This allows a quick computer search through the data which is difficult... [Pg.135]

Fig. 17. (A) Principle of the searching routine showing various parameters describ-... Fig. 17. (A) Principle of the searching routine showing various parameters describ-...
With the seven-helix bundle construct in hand, we turned our attention to incorporation of the three extracellular (EC) loops. The cytoplasmic loops were disregarded because they would not be involved in molecular recognition between the receptor and the SFLLRN ligand. Extracellular loop 3, the smallest of the three EC loops, was added first via the loop-search routine in the Biopolymer mode of Sybyl. The loop backbone choices found in the Brookhaven PDB were examined in 3-D and selected on the basis of their fit to the overall protein structure. After the side chains were added to EC3, some of them had to be rotated to avoid unfavorable steric interactions with other parts of the protein. Then, the entire protein was energy minimized. Extracellular loop 1 was then added, followed by EC2, and each time the loop selection was made after analyzing the protein in 3-D. Side chains of amino... [Pg.258]

There are many different types of search routines used to locate optimum operating conditions. One approach is to make a large number of runs at different combinations of temperature, reaction time, hydrogen partial pressure, and catalyst amount, and then run a multivariable computer search routine (like the Hooke-Jeeves method or Powell method). A second approach is to formulate a mathematical model from the experimental results and then use an analytical search method to locate the optimum. The formulation of a mathematical model is not an easy task, and in many cases, this is the most critical step. Sometimes it is impossible to formulate a mathematical model for the system, as in the case of the system studied here, and an experimental search must be performed. [Pg.196]

The emperical parameters S Q, S2Q, K-Q, K, A E-, and AE were determined by a numerical search routine. Figure 3 compares the theoretical curves with the experimental data and represents a satisfactory curve fit. [Pg.203]

A numerical search routine was applied to determine the value of K and A E. Figure 4 compares the theoretical curve with the experimental data and represents a satisfactory curve fit. The total sulfur content and SRC sulfur content for hydrotreated product were plotted (Figure 5), and a linear relationship was shown to exist between them. [Pg.205]

The development and use of various protein sequence databases for automated search routines (Eng et al., 1994 Clauser et al., 1999) are an essential component of protein analysis that uses mass spectrometry techniques. These programs (i.e., SEQUEST, MASCOT) require only a few peptides for matching therefore, the absence of a match for a particular peptide does not affect the search performance. Using protein database searches provides an efficient way of confirming a putative sequence from corresponding full-scan mass spectrometry and MS/MS data. [Pg.73]

A three parameter search routine was used to evaluate the binary interaction parameters which minimize the following objective function ... [Pg.111]

The third of the three adjacent peaks (29.207 minutes) is readily identified as 2-hydroxybenzaldehyde (salicylaldehyde) by comparison of the MS or IR spectrum with library data. It should be noted that the automated search routine in the MS software picked 3-and 4-hydroxybenzaldehyde as better matches than the 2-hydroxy compound, even though the 76 ion in the spectrum of the unknown is present only in the mass spectrum of the 2-hydroxy compound. However, the IR search routine correctly identified the 2-isomer. This illustrates that casual operators who rely on automated search routines for compound identification are much less likely to make errors when they have access to both IR and MS searching. [Pg.67]


See other pages where Search Routine is mentioned: [Pg.127]    [Pg.159]    [Pg.345]    [Pg.266]    [Pg.200]    [Pg.23]    [Pg.244]    [Pg.66]    [Pg.1009]    [Pg.361]    [Pg.372]    [Pg.140]    [Pg.396]    [Pg.497]    [Pg.255]    [Pg.164]    [Pg.139]    [Pg.208]    [Pg.74]    [Pg.67]    [Pg.115]    [Pg.122]    [Pg.200]    [Pg.140]    [Pg.396]    [Pg.193]    [Pg.246]    [Pg.278]    [Pg.62]    [Pg.71]   


SEARCH



Computer programs, library search routines

Library search routines, computer

Routine