Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Vibrations analysis

The response of the tie rods to the effects of the fluid flow was determined using analyses which are conservative in nature. The natural frequency of the tie rod is a function of the rod diameter and length and the tension in the rod. During assembly of the core support structure, the tie rods are placed in tension by tightening the nuts at their lower ends. [Pg.111]

The torque on the nuts is specified so that the natural frequency of the rods will be approximately 19 cps in air and with no loading due to core weight. The relationship between this natural frequency and the torque on the tie rod nuts was determined experimentally on the actual structure during initial fit up at the shop. [Pg.111]

Following installation of the core support structure in the reactor the tie rods will be immersed in water which will cause the natural frequency of the rods to drop by approximately 5 per cent. However, installation of the core will increase the tension in the tie rods and the natural frequency of the tie rods will increase approximately 8 per cent, more than offsetting the effect of the water. [Pg.111]

It is seen that the maximum amplitude of vibration is 0.0153 in and the maximum bending moment is 39.5 in lb. The corresponding maximum alternating stress is 403 psi. [Pg.111]

The analysis described above was for the case of the tie rod natural frequency being slightly greater than the exciting frequency (19 cps vs. 17.5 cps). While it is felt that the exciting frequency used will be the maximum possible and that the natural frequency used is close to the actual, the case of the natural frequency being in resonance with the exciting [Pg.112]


Laborelec s future realisations are vibration analysis, control of inspection robots, and all types of system monitoring. LabVIEW will be used as common tool for developers for the coming years. The synergy effect of a common language for everything concerning acquisition, analysis and processing of data will be beneficial for the whole company. [Pg.1009]

Also, the result of any diffraction-based trial-and-error fitting is not necessarily unique it is always possible that there exists another untried structure that would give a better fit to experiment. Hence, a multi-teclmique approach that provides independent clues to the structure is very fniithil and common in surface science such clues include chemical composition, vibrational analysis and position restrictions implied by other structural methods. This can greatly restrict the number of trial structures which must be investigated. [Pg.1752]

Ushio J, Papal I, St-Amant A and Salahub D R 1992 Vibrational analysis of formate adsorbed on Nl(110) LCGTO-MCP-LSD study Surf. Sol. 262 LI34-8... [Pg.2234]

Tchenio P, Myers A B and Moerner W E 1993 Vibrational analysis of the dispersed fluorescence from single molecules of terrylene in polyethylene Chem. Phys. Lett. 213 325-32... [Pg.2508]

Generally, a vibration analysis calculation should be performed after a geometry optim ization with th e sarn e meth od, Th is eri stires th at the ealeti laliori of second derivatives is perform ed at a eon figuration for which all first derivatives are zero. [Pg.124]

XoLicc that although thii energies and Corces are evaliiatecl r iian-Liim mechanically in IlyperChcm. the vibrational analysis has been purely classical. [Pg.336]

The method of vibrational analysis presented here ean work for any polyatomie moleeule. One knows the mass-weighted Hessian and then eomputes the non-zero eigenvalues whieh then provide the squares of the normal mode vibrational frequeneies. Point group symmetry ean be used to bloek diagonalize this Hessian and to label the vibrational modes aeeording to symmetry. [Pg.356]

There are three steps in carrying out any quantum mechanical calculation in HyperChem. First, prepare a molecule with an appropriate starting geometry. Second, choose a calculation method and its associated (Setup menu) options. Third, choose the type of calculation (single point, geometry optimization, molecular dynamics, Langevin dynamics, Monte Carlo, or vibrational analysis) with the relevant (Compute menu) options. [Pg.107]

A vibrations calculation is the first step of a vibrational analysis. It involves the time consuming step of evaluating the Hessian matrix (the second derivatives of the energy with respect to atomic Cartesian coordinates) and diagonalizing it to determine normal modes and harmonic frequencies. For the SCFmethods the Hessian matrix is evaluated by finite difference of analytic gradients, so the time required quickly grows with system size. [Pg.124]

To perform a vibrational analysis, choose Vibrationson the Compute menu to invoke a vibrational analysis calculation, and then choose Vibrational Dectrum to visualize the results. The Vibrational Spectrum dialog box displays all vibrational frequencies and a simulated infrared spectrum. You can zoom and pan in the spectrum and pick normal modes for display, using vectors (using the Rendering dialog box from Display/Rendering menu item) and/or an im ation. [Pg.124]

HyperChem performs a vibrational analysis at the molecular geometry shown in the HyperChem workspace, without any automatic pre-optimization. HyperChem may thus give unreasonable results when you perform vibrational analysis calculations with an unoptimized molecular system, particularly for one far from optimized. Because the molecular system is not at a stationary point, neither at a local minimum nor at a local maximum, the vibra-... [Pg.332]

Vibration analysis Vibration control Vibration damping Vibration isolation Vibrations... [Pg.1051]

Reliability. There has been a significant rise in interest among pump users in the 1990s to improve equipment reflabiUty and increase mean time between failures. Quantifiable solutions to such problems are being sought (61). Statistical databases (qv) have grown, improved by continuous contributions of both pump manufacturers and users. Users have also learned to compile and interpret these data. Moreover, sophisticated instmmentation has become available. Examples are vibration analysis and pump diagnostics. [Pg.302]

The repeat distance along the chain axis (0.468 nm) is significantly less than that calculated for a planar zigzag stmcture. Therefore, the polymer must be in some other conformation (65—67). Based on k and Raman studies of PVDC single crystals and normal vibration analysis, the best conformation appears to be where the skeletal angle, is 120°, and the torsional of opposite sign) is 32.5°. This conformation is in... [Pg.430]

Further investigations were carried out with 3-methyldiazirine (72JCP(57)94l) and with 3-chloro-3-methyldiazirine (72JSP(42)403). The high resolution electronic spectra were submitted to vibrational analysis deuterated derivatives were included. All excitation and ground state fundamentals observed could be assigned. [Pg.203]

Fairmont Press, 1993. John W. Diifor and William E. Nelson, Centiifugol Tump Sourcebook, McGraw-Hill, 1992. Trocess Tumps, ITT Fluid Technology Corporation, 1992. James Corley, The Vibration Analysis of Pumps A Tutorial, Foiiii h International Pump Symposium, Texas A M University, Houston, Texas, May 1987. [Pg.898]

FIG. 10-64 Limitations on machinery vibrations analysis systems and transducers. [Pg.917]

From this it can be seen that vibration is the universal manifestation that something is wrong. Therefore, many units are equipped with instruments that continuously monitor vibration. Numerous new instruments for vibration analysis have become available. Frequency can be accurately determined and compared with computations, and by means of oscilloscopes the waveform and its harmonic components can be analyzed. Such equipment is a great help in diagnosing a source of trouble. [Pg.2505]


See other pages where Vibrations analysis is mentioned: [Pg.2495]    [Pg.124]    [Pg.124]    [Pg.143]    [Pg.332]    [Pg.332]    [Pg.333]    [Pg.333]    [Pg.334]    [Pg.335]    [Pg.336]    [Pg.337]    [Pg.338]    [Pg.288]    [Pg.54]    [Pg.143]    [Pg.332]    [Pg.332]    [Pg.333]    [Pg.333]    [Pg.335]    [Pg.337]    [Pg.442]    [Pg.775]    [Pg.403]   
See also in sourсe #XX -- [ Pg.419 ]

See also in sourсe #XX -- [ Pg.75 , Pg.469 ]

See also in sourсe #XX -- [ Pg.267 ]

See also in sourсe #XX -- [ Pg.206 , Pg.211 , Pg.212 ]




SEARCH



Acquisition and Analysis in Biomedical Vibrational Spectroscopy

Adsorbed molecules, vibrational analysis

Analysis of vibrational spectra

Analysis torsional vibration

Analysis vibrating reed

Bearings vibration analysis

Benzene molecular vibrations analysis

C6H6, analysis of vibrational spectra potential energy

Carbon monoxide vibrational analysis

Chain computer vibration analysis

Compressor types and operation computer vibration analysis

Computer-based vibration analysis

Controlled reactions, vibrational analysis

Conventional vibration analysis methods

Couplings computer vibration analysis

Crystals, vibrational analysis

Damping vibrational analysis

Decomposition vibrational analysis

Displacement, vibrational analysis

Extended structures vibrational analysis

Frequency domain analysis vibration data

Harmonic vibrational analysis

Inertia, vibrational analysis

Isotopes, vibrational analysis

Methane vibrational analysis

Molecular vibrations classical mechanics analysis

Molecular vibrations quantum mechanics analysis

Noise vibration analysis detection

Normal Vibration Analysis

Normal mode analysis of molecular vibrations

Normal vibrational mode analysis

Partial Hessian vibrational analysis

Periodic frequency, vibrational analysis

Periodic motion, vibrational analysis

Poly vibrational analysis

Probes vibrational analysis

Quality control using vibration analysis

Random Vibration Analysis

Random Vibration Analysis of Nonstationary Response

Rotational velocity, vibrational analysis

Rotor Dynamics and Vibration Analysis

Rotors vibrational analysis

Simplification of the Molecular Vibration Analysis

Spectroscopic analysis vibrational

Spectrum analysis vibration measurement

Structural analysis vibrational

Subject vibrational analysis

Translational velocity, vibrational analysis

Vibration Monitoring and Analysis

Vibration computer-based analysis applications

Vibration computer-based analysis applications bearings

Vibration computer-based analysis applications running speed

Vibration computer-based analysis applications transducer locations with

Vibrational Spectroscopic Analysis of Hard Tissues

Vibrational analysis

Vibrational analysis

Vibrational analysis acceleration

Vibrational analysis accelerometers

Vibrational analysis amplitude

Vibrational analysis complex vibration

Vibrational analysis damped systems

Vibrational analysis deterministic vibration

Vibrational analysis forced vibration

Vibrational analysis forcing frequency

Vibrational analysis free vibration

Vibrational analysis frequency components

Vibrational analysis gears

Vibrational analysis principles

Vibrational circular dichroism analysis

Vibrational frequency analysis

Vibrational intensity analysis

Vibrational modes and analysis for H2 complexes effect

Vibrational modes and analysis for H2 complexes in W

Vibrational projectional analysis

Vibrational spectroscopy and conformational analysis of oligonucleotides

Vibrational spectroscopy normal coordinate analysi

Vibrational spectroscopy normal coordinate analysis

Vibrational spectroscopy surface analysis

Vibrational state analysis

Vibrational state analysis effects

Vibrational state analysis systems

Water molecule vibrational analysis

Wilson vibrational analysis

© 2024 chempedia.info