Frequency domain analysis vibration data

In the analysis of vibration data there is often the need to transform the data from the time domain to the frequency domain or, in other words, to obtain a spectrum analysis of the vibration. The original and inexpensive system to obtain this analysis is the tuneable swept-filter analyzer. Because of inherent limitations of this system, this process, despite the use of automated sweep, is time-consuming when analyzing low frequencies. When the spectra data needs to be digitized for computer inputing, there are further limitations in capability of tuneable filter-analysis systems. [Pg.670]

The process of vibration analysis requires gathering complex machine data and deciphering it. As opposed to the simple theoretical vibration curves shown in Figures 43.1 and 43.2, the profile for a piece of equipment is extremely complex. This is tme because there are usually many sources of vibration. Each source generates its own curve, but these are essentially added together and displayed as a composite profile. These profiles can be displayed in two formats time-domain and frequency-domain. [Pg.665]

Most of the early vibration analysis was carried out using analog equipment, which necessitated the use of time-domain data. The reason for this is that it was difficult to convert time-domain data to frequency-domain data. Therefore, frequency-domain capability was not available until microprocessor-based analyzers incorporated a straightforward method (i.e.. Fast Fourier Transform, FFT) of transforming the time-domain spectmm into its frequency components. [Pg.683]

Repeated twisting of the spindle s tube or the solid shaft used in jackshafts results in a reduction in the flexible drive s stiffness. When this occurs, the drive loses some of its ability to absorb torsional transients. As a result, damage may result to the driven unit. Unfortunately, the limits of single-channel, frequency-domain data acquisition prevents accurate measurement of this failure mode. Most of the abnormal vibration that results from fatigue occurs in the relatively brief time interval associated with startup, when radical speed changes occur, or during shutdown of the machine-train. As a result, this type of data acquisition and analysis cannot adequately capture these... [Pg.751]


See other pages where Frequency domain analysis vibration data is mentioned: [Pg.196]    [Pg.699]    [Pg.806]    [Pg.347]    [Pg.137]    [Pg.32]    [Pg.587]   
See also in sourсe #XX -- [ Pg.727 , Pg.760 , Pg.761 ]