Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Validation definitions

GLl Validation definitions Validation of analytical procedures definition and terminology... [Pg.132]

The traditional approach to optimize a process is schematically shown in Figure 2 its principle elements are the development of a model, model validation, definition of an objective function and an optimizing algorithn. The "model" can be (a) theoretical, (b) empirical or (c) a combination of the two. [Pg.100]

Independent reference methods - one organization Two or more independent reference methods, each based on an entirely conceptually different principle of measurement, independent in theory and experimental procedure, applied in replicate, within a single organization, of the highest reputational quality, by two or more expert analysts, working independently. The methods used can, naturally, include definitive methods, and the results should be corroborated by a third or additional, independently different, accurately characterized, well established, thoroughly validated, definitive, reference, or other methods. [Pg.53]

In the case of non-Newtonian flow, it is necessary to use an appropriate apparent viscosity. Although the apparent viscosity (ia is defined by equation 1.71 in the same way as for a Newtonian fluid, it no longer has the same fundamental significance and other, equally valid, definitions of apparent viscosities may be made. In flow in a pipe, where the shear stress varies with radial location, the value of fxa varies. As pointed out in Example 3.1, it is the conditions near the pipe wall that are most important. The value of /j.a evaluated at the wall is given by... [Pg.114]

Thus one arrives at a valid definition of tannins for plant chemistry, insofar as their characteristic properties are concerned, without reference to the leather industry. Such a definition has been given by Swain and Bate-Smith (28) ... [Pg.68]

Most firms today start by qualifying each subsystem. To qualify, of course, means to establish convincing evidence that something happens as intended, which matches the validation definition (in more explicit terms, however). Installation qualification may be defined as documented verification that all key aspects of the installation adhere to manufacturer s recommendations, appropriate codes, and approved design intentions. Operational qualification is documented verification that a system or subsystem performs as intended throughout all specified operating ranges. [Pg.839]

The organization required to support and deliver the validation Definition of the validation schedule... [Pg.624]

This is different from the total strain because some of the terms S, may be positive and some negative. The total strain can be defined as a scalar quantity, Sss, and, while several equally valid definitions for this are given in the literature, the two most commonly used in the earth sciences literature (e g. Redfem and Salje 1987, Salje 1993) are... [Pg.41]

Analysts and end users of the measurement results should be aware of the new dimension of the procedure validation definition given in ISO/IEC 17025, which requires that a procedure s performance parameters are fit for a specific intended use. In other words this means that the work of an analyst is not finished when performance capabilities of a specific method (or preferably procedure ) are evaluated, but he/she has to go a step further and check whether these characteristics are in compliance with the client s needs. Of course, it is up to the client to specify his/her re-quirements/properties the result should have. Furthermore, ISO/IEC 17025 is introducing evaluation of measurement uncertainty as a mean of performing validation through systematic assessment of all quantities influencing the result. [Pg.119]

Unfortunately, it is impossible to predict the basic parameters such as logP or PXa with high precision. In addition, a universally valid definition of drug-likeness is not yet known, and thus preliminary methods must be used. [Pg.572]

Note we have ignored Vsat for the T4 equation. Note also that if we take Vsat to be greater than 10% of Vdrive, there is no valid definition for T4 (the way we ha ve defined it). [Pg.226]

Recognize valid definitions of, and use in a correct context, the terms, concepts and principles in the following Table. (All Questions)... [Pg.111]

By applying the generally valid definitions of the temperature and pressure dependence of chemical potential to equation 43 relations... [Pg.22]

Protein domains, the next level up in the hierarchy of protein constitution, are important enough to warrant a separate discussion. Domains can be defined based on function, structure, or sequence characterization in many cases the different approaches are compatible. We naturally adopt a structure-based definition a protein domain is a spatially distinct structure (or structural component) that could conceivably fold and function in isolation [63]. Some proteins consist of a single domain, while others are composed of multiple domains each folded separately from a subsection of the underlying amino acid chain. To this point, our notion of the genotype to phenotype relationship has been protein sequence protein structure. Given the discrete spatial nature of domains, protein SM sequence -> domain would be an equally valid definition. In fact, the notion of a protein fold (as in, "this fold is highly designable") translates naturally to the protein domain concept. [Pg.16]

For further considerations, it has to be mentioned that the activity of ionic species is a difficult and ambiguous concept and provides a valid definition of a standard state. Hence, under consideration of cations (for example, Na+), being present in the melt, the equilibrium (1) can be written as... [Pg.598]

The hardness of a body is understood to be the mechanical resistance of this body to its penetration by another. A generally valid definition of hardness suitable for all materials does not exist neither are there generally applicable test methods. The various hardness scales, however, can be roughly related to each other (Table 11-6). [Pg.455]

Sentences have a number of possible valid definitions. We use one based on the writing as this is most helpful to TTS. [Pg.77]

When CRMs are not available, trace element standards or uncertified control materials may be purchased with manufacturer certificates stating purity. However, it is the responsibility of the laboratory to document that the quality of such standards is satisfactory [39,40]. Eventually a conventional true value may be established by a reference laboratory, and whenever possible a validated definitive method should be used [5]. Using uncertified quality control samples the uncertainty of the reference value should be considered and expressed as the 0.95 confidence interval of (Xy, i.e., XY t( - l)o.9750-YVn. A practical criterion is that t(n - l)o.975ffY should be less than a defined fraction of ixy, e.g., 5%. [Pg.55]

The objective of this chapter will be to propose a scheme for demonstrating the accuracy, precision, and suitability of sensors. As will be seen, no matter what sensor, device, or measurement approach is chosen, these three simple criteria will be at the heart of the calibration/validation exercise. Depending on the complexity of the process, the sensor system, and process requirements necessary to achieve a mechanistic understanding, more parameters may be necessary. For example, linearity, range, specificity, robustness, raggedness, detection limit, and quantification hmit may also need to be investigated. By definition (see calibration and validation definition in this chapter), accuracy, precision, and suitability will be the minimum requirements for the cahbration/validation exercise of process sensors. [Pg.246]

Finally, the shear rate as deflned by Equation 2.36b is clearly the appropriate argument for the viscosity function only for one-dimensional flows like the one used here. We need a quantity that reduces to dvx/dy for the one-dimensional flow but is properly invariant to the way in which we choose to deflne our coordinate system. The appropriate function, which follows directly from the principles of matrix algebra, is one half the second invariant of the rate of deformation, which is usually denoted Ud- Ud is shown in Table 2.6, where it is identical to the dissipation function O divided by r] for the special case of Newtonian fluids. (It is important to keep in mind that the function /) in Table 2.6 is the proper form for the dissipation only for a Newtonian fluid, whereas IId is a universally valid definition that depends only on the velocity field.) For an arbitrary flow field, then, the power-law and Carreau-Yasuda equations would be written, respectively. [Pg.35]

Self-determination for nations was little more than lip service. Besides political considerations as described above, one more fundamental problem was unanswered and to a certain degree stiU remains unsolved today. There was no generally valid definition of a nation. Without knowing to whom self-determination could be granted, it was doomed to be a political tool for the powerful that could be used at their discretion. There was no right to self-determination yet. Even calling it a principle may be too much. The dictionary defines principle as a comprehensive and fundamental law, doctrine, or assumption or a rule or code of conduct. Self-determination was certainly not a fundamental law in the years following World War I and as it was applied so very inconsistently that one can hardly speak of a code of conduct. [Pg.189]

This is a valid definition, as it only requires that the small component be integrable, which is certainly the case sinee must be square integrable in order to normalize the Dirac wave function. The pseudo-large component now has the same symmetry properties as the large component. The nonrelativistic limit of the pseudo-large component is the large component, since... [Pg.279]

API method development effort during dmg discovery is limited. In phase I, all impurities must be separated from a major peak to ensure peak purity. In phase n, a synthetic route needs to be selected and optimized. The method needs to be challenged when the route or process is changed. In phase III, the route is selected and the process is finalized. Critical Quality Attribute (CQA) impurities are defined and their references are typically prepared for method development. Method robustness and ruggedness must be demonstrated, and relative response factors of all impurities CQAs are determined before regulatory filing such as NDA and MAA. The validated definitive methods are transferred to manufacturing sites. [Pg.10]

In 1836, the term catalysis was introduced by Berzelius. Ostwald defined it in 1895 as a catalyst accelerates a chemical reaction without affecting the position of the equilibrium and is still a valid definition. Catalysis is a cyclic process in, which catalyst in one form is involved in chemical bonding with the reactants and the products are released from another form, thus catalyst regenerates to its initial state (Fig. 9.1) [1]. [Pg.330]


See other pages where Validation definitions is mentioned: [Pg.1]    [Pg.117]    [Pg.118]    [Pg.178]    [Pg.27]    [Pg.166]    [Pg.167]    [Pg.137]    [Pg.3]    [Pg.218]    [Pg.82]   
See also in sourсe #XX -- [ Pg.8 ]

See also in sourсe #XX -- [ Pg.2 ]

See also in sourсe #XX -- [ Pg.127 ]

See also in sourсe #XX -- [ Pg.409 ]




SEARCH



Validity definition

© 2024 chempedia.info