Beer s law states that the absorbance is concentration related. This means that in order to obtain low detection limits, the chromatographic band must be as concentrated as possible to give high peak height. [Pg.81]

Depending on the light source, the UV detector can operate from 190 nm and well into the visible area. The UV detector can be of various kinds, for example, filter photometric detectors, spectrophotometric detectors, and diode array detectors. [Pg.82]


The concentration of caffeine in a typical serving of coffee and soda is determined in this experiment. Separations are achieved using a Gjg column with a mobile phase of 30% v/v methanol in water, with UV detection at a wavelength of 254 nm. [Pg.612]

This experiment focuses on developing an HPLG separation capable of distinguishing acetylsalicylic acid, paracetamol, salicylamide, caffeine, and phenacetin. A Gjg column and UV detection are used to obtain chromatograms. Solvent parameters used to optimize the separation include the pH of the buffered aqueous mobile phase, the %v/v methanol added to the aqueous mobile phase, and the use of tetrabutylammonium phosphate as an ion-pairing reagent. [Pg.612]

Students determine the concentrations of caffeine, acetaminophen, acetylsalicylic acid, and salicylic acid in several analgesic preparations using both CZE (70 mM borate buffer solution, UV detection at 210 nm) and HPLC (C18 column with 3% v/v acetic acid mixed with methanol as a mobile phase, UV detection at 254 nm). [Pg.614]

Hydroquinone can be deterrnined spectrophotometricaHy at 292 nm in methanol after a sample is evaporated to dryness to remove the interference of acrolein. An alternative method is high performance Hquid chromatography on 10-p.m LiChrosorb RP-2 at ambient temperature with 2.0 mL/min of 20%(v/v) 2,2,4-trimethylpentane, 79.20% chloroform, and 0.80 % methanol with uv detection at 292 nm. [Pg.124]

Reversed-phase hplc has been used to separate PPG into its components using evaporative light scattering and uv detection of their 3,5-dinitroben2oyl derivatives. Acetonitrile—water or methanol—water mixtures effected the separation (175). Polymer glycols in PUR elastomers have been identified (176) by pyrolysis-gc. The pyrolysis was carried out at 600°C and produced a small amount of ethane, CO2, propane, and mostiy propylene, CO, and CH4. The species responsible for a musty odor present in some PUR foam was separated and identified by gc (Supelco SP-2100 capillary column)... [Pg.354]

An hplc assay was developed suitable for the analysis of enantiomers of ketoprofen (KT), a 2-arylpropionic acid nonsteroidal antiinflammatory dmg (NSAID), in plasma and urine (59). Following the addition of racemic fenprofen as internal standard (IS), plasma containing the KT enantiomers and IS was extracted by Hquid-Hquid extraction at an acidic pH. After evaporation of the organic layer, the dmg and IS were reconstituted in the mobile phase and injected onto the hplc column. The enantiomers were separated at ambient temperature on a commercially available 250 x 4.6 mm amylose carbamate-packed chiral column (chiral AD) with hexane—isopropyl alcohol—trifluoroacetic acid (80 19.9 0.1) as the mobile phase pumped at 1.0 mL/min. The enantiomers of KT were quantified by uv detection with the wavelength set at 254 nm. The assay allows direct quantitation of KT enantiomers in clinical studies in human plasma and urine after adrninistration of therapeutic doses. [Pg.245]

In the 1990s hplc has become widely used in the flavor and fragrance industry to measure vanillin and other phenoHc compounds. Routine methods have been developed that are particularly adapted to thermosensitive products, such as vanillin and its derivative products, with elution gradient and uv detection at given wavelengths. Certain critical impurities can thus routinely be traced to very low (10 ppm) concentrations. [Pg.401]

For more specific analysis, chromatographic methods have been developed. Using reverse-phase columns and uv detection, hplc methods have been appHed to the analysis of nicotinic acid and nicotinamide in biological fluids such as blood and urine and in foods such as coffee and meat. Derivatization techniques have also been employed to improve sensitivity (55). For example, the reaction of nicotinic amide with DCCI (AT-dicyclohexyl-0-methoxycoumarin-4-yl)methyl isourea to yield the fluorescent coumarin ester has been reported (56). After separation on a reversed-phase column, detection limits of 10 pmol for nicotinic acid have been reported (57). [Pg.51]

We have developed the method for quantitative analysis of urinary albumin with CE. A capillary electrophoresis systems Nanophor 01 (Institute of Analytical Instmmentation, Russian Academy of Sciences, Saint-Petersburg) equipped with a UV-detector was used to determine analyte. Separation was achieved using 45 cmx30 p.m I.D. fused silica capillary column with UV-detection at 214 nm. [Pg.100]

The major problems in assay of protein by CE are the low efficiency and reproducibility by presents of protein adsorption on the inner surface of a capillary, and poor concentration sensitivity UV-detection. [Pg.100]

Catechin and epicatechin are two flavanols of the catechin family. They are enantiomers. The capillary zone electrophoresis (CE) methods with UV-detection were developed for quantitative determination of this flavanols in green tea extracts. For this purpose following conditions were varied mnning buffers, pH and concentration of chiral additive (P-cyclodextrin was chosen as a chiral selector). Borate buffers improve selectivity of separation because borate can make complexes with ortho-dihydroxy groups on the flavanoid nucleus. [Pg.114]

FIGURE l.l Hydrophobic interaction and reversed-phase chromatography (HIC-RPC). Two-dimensional separation of proteins and alkylbenzenes in consecutive HIC and RPC modes. Column 100 X 8 mm i.d. HIC mobile phase, gradient decreasing from 1.7 to 0 mol/liter ammonium sulfate in 0.02 mol/liter phosphate buffer solution (pH 7) in 15 min. RPC mobile phase, 0.02 mol/liter phosphate buffer solution (pH 7) acetonitrile (65 35 vol/vol) flow rate, I ml/min UV detection 254 nm. Peaks (I) cytochrome c, (2) ribonuclease A, (3) conalbumin, (4) lysozyme, (5) soybean trypsin inhibitor, (6) benzene, (7) toluene, (8) ethylbenzene, (9) propylbenzene, (10) butylbenzene, and (II) amylbenzene. [Reprinted from J. M. J. Frechet (1996). Pore-size specific modification as an approach to a separation media for single-column, two-dimensional HPLC, Am. Lab. 28, 18, p. 31. Copyright 1996 by International Scientific Communications, Inc.. Shelton, CT.]... [Pg.12]

As a final example of column durability and solvent resistance in small pore gels we were able to resolve nylon 6 oligomers using a methanol mobile phase and 205-nm UV detection as shown in Figure 13.29. In fact, polar solvents such as acetone, acetonitrile, methanol, and 2-propanol, are used routinely as needed with no ill effects. [Pg.382]

The Dnseoc group was developed as a base-labile protective group for the 5 -hydroxyl in oligonucleotide synthesis. It is cleaved with DBU in aprotic solvents. The condensation of oligonucleotide synthesis can be monitored by UV detection at 350 nm or by fluorescence at 530 nm of the liberated vinylsulfone. ... [Pg.541]

Figure 2.9 (a) Liquid clnomatogram (UV detection at 220 nm) obtained after initial sample... [Pg.30]

Figure 11.16 Chromatograms of plasma samples obtained by using SPE-SFC with super-aitical desorption of the SPE cartridge (a) blank plasma (20 p.1), UV detection at 215 nm (b) blank plasma (20 p.1), UV detection at 360 nm (c) plasma (1 ml) containing 20 ng mitomycin C (MMC), UV detection at 360 nm. Reprinted from Journal of Chromatography, 454, W. M. A. Niessen et al., Phase-system switching as an on-line sample pretreatment in the bioanalysis of mitomycin C using supercritical fluid cliromatography, pp. 243-251, copyright 1988, with permission from Elsevier Science. Figure 11.16 Chromatograms of plasma samples obtained by using SPE-SFC with super-aitical desorption of the SPE cartridge (a) blank plasma (20 p.1), UV detection at 215 nm (b) blank plasma (20 p.1), UV detection at 360 nm (c) plasma (1 ml) containing 20 ng mitomycin C (MMC), UV detection at 360 nm. Reprinted from Journal of Chromatography, 454, W. M. A. Niessen et al., Phase-system switching as an on-line sample pretreatment in the bioanalysis of mitomycin C using supercritical fluid cliromatography, pp. 243-251, copyright 1988, with permission from Elsevier Science.
Figure 12.7 Cliromatograms of a polycarbonate sample (a) microcolumn SEC ti ace (b) capillary GC ti ace of inti oduced fractions. SEC conditions fused-silica (30 cm X 250 mm i.d.) packed with PL-GEL (50 A pore size, 5 mm particle diameter) eluent, THE at aElow rate of 2.0ml/min injection size, 200 NL UV detection at 254 nm x represents the polymer additive fraction ti ansfeired to EC system (ca. 6 p-L). GC conditions DB-1 column (15m X 0.25 mm i.d., 0.25 pm film thickness) deactivated fused-silica uncoated inlet (5 m X 0.32 mm i.d.) temperature program, 100 °C for 8 min, rising to 350 °C at a rate of 12°C/min flame ionization detection. Peak identification is as follows 1, 2,4-rert-butylphenol 2, nonylphenol isomers 3, di(4-tert-butylphenyl) carbonate 4, Tinuvin 329 5, solvent impurity 6, Ii gaphos 168 (oxidized). Reprinted with permission from Ref. (14). Figure 12.7 Cliromatograms of a polycarbonate sample (a) microcolumn SEC ti ace (b) capillary GC ti ace of inti oduced fractions. SEC conditions fused-silica (30 cm X 250 mm i.d.) packed with PL-GEL (50 A pore size, 5 mm particle diameter) eluent, THE at aElow rate of 2.0ml/min injection size, 200 NL UV detection at 254 nm x represents the polymer additive fraction ti ansfeired to EC system (ca. 6 p-L). GC conditions DB-1 column (15m X 0.25 mm i.d., 0.25 pm film thickness) deactivated fused-silica uncoated inlet (5 m X 0.32 mm i.d.) temperature program, 100 °C for 8 min, rising to 350 °C at a rate of 12°C/min flame ionization detection. Peak identification is as follows 1, 2,4-rert-butylphenol 2, nonylphenol isomers 3, di(4-tert-butylphenyl) carbonate 4, Tinuvin 329 5, solvent impurity 6, Ii gaphos 168 (oxidized). Reprinted with permission from Ref. (14).
Figure 12.11 Coupled SEC-RPLC separation of compound Chemigum mbber stock (a) SEC ti ace (b) RPLC trace of fraction 1, dibutylphthalate (c) RPLC trace of fraction 2, elemental sulfur. Coupled SEC conditions MicroPak TSK 3000H (50 cm) X 2000H (50 cm) X 1000 H (80 cm) columns (8 mm i.d.) eluent, THE at a flow rate of 1 mL/min UV detection at 215 nm (1.0 a.u.f.s.) injection volume, 200 p-L. RPLC conditions MicroPak MCH (25 cm X 2.2 mm i.d.) column flow rate, 0.5 mL/min injection volume, lOpL gradient, acetonitrile-water (20 80 v/v) to 100% acetonitrile at 3% acetonitrile/min UV detection at 254 nm (0.05 a.u.f.s.). Reprinted from Journal of Chromatography, 149, E. L. Jolmson et al., Coupled column cliromatography employing exclusion and a reversed phase. A potential general approach to sequential analysis , pp. 571-585, copyright 1978, with permission from Elsevier Science. Figure 12.11 Coupled SEC-RPLC separation of compound Chemigum mbber stock (a) SEC ti ace (b) RPLC trace of fraction 1, dibutylphthalate (c) RPLC trace of fraction 2, elemental sulfur. Coupled SEC conditions MicroPak TSK 3000H (50 cm) X 2000H (50 cm) X 1000 H (80 cm) columns (8 mm i.d.) eluent, THE at a flow rate of 1 mL/min UV detection at 215 nm (1.0 a.u.f.s.) injection volume, 200 p-L. RPLC conditions MicroPak MCH (25 cm X 2.2 mm i.d.) column flow rate, 0.5 mL/min injection volume, lOpL gradient, acetonitrile-water (20 80 v/v) to 100% acetonitrile at 3% acetonitrile/min UV detection at 254 nm (0.05 a.u.f.s.). Reprinted from Journal of Chromatography, 149, E. L. Jolmson et al., Coupled column cliromatography employing exclusion and a reversed phase. A potential general approach to sequential analysis , pp. 571-585, copyright 1978, with permission from Elsevier Science.
Figure 12.18 LC-SFC analysis of mono- and di-laurates of poly (ethylene glycol) ( = 10) in a surfactant sample (a) normal phase HPLC trace (b) chromatogram obtained without prior fractionation (c) chromatogram of fraction 1 (FI) (d) chromatogram of fraction 2 (F2). LC conditions column (20 cm X 0.25 cm i.d.) packed with Shimpak diol mobile phase, w-hexane/methylene chloride/ethanol (75/25/1) flow rate, 4 p.L/min UV detection at 220 nm. SFC conditions fused-silica capillary column (15 m X 0.1 mm i.d.) with OV-17 (0.25 p.m film thickness) Pressure-programmed at a rate of 10 atm/min from 80 atm to 150 atm, and then at arate of 5 atm/min FID detection. Reprinted with permission from Ref. (23). Figure 12.18 LC-SFC analysis of mono- and di-laurates of poly (ethylene glycol) ( = 10) in a surfactant sample (a) normal phase HPLC trace (b) chromatogram obtained without prior fractionation (c) chromatogram of fraction 1 (FI) (d) chromatogram of fraction 2 (F2). LC conditions column (20 cm X 0.25 cm i.d.) packed with Shimpak diol mobile phase, w-hexane/methylene chloride/ethanol (75/25/1) flow rate, 4 p.L/min UV detection at 220 nm. SFC conditions fused-silica capillary column (15 m X 0.1 mm i.d.) with OV-17 (0.25 p.m film thickness) Pressure-programmed at a rate of 10 atm/min from 80 atm to 150 atm, and then at arate of 5 atm/min FID detection. Reprinted with permission from Ref. (23).
Figure 12.21 SFC-GC heait-cut analysis of chrysene from a complex hydrocarbon mixture (a) SFC ttace (UV detection) (b) GC trace without heait-cut (100% transfer) (c) GC ti ace of heatt-cut fraction (flame-ionization detection used for GC experiments). Reprinted from Journal of High Resolution Chromatography, 10, J. M. Levy et al., On-line multidimensional supercritical fluid chromatography/capillaiy gas cluomatography , pp. 337-341, 1987, with permission from Wiley-VCFI. Figure 12.21 SFC-GC heait-cut analysis of chrysene from a complex hydrocarbon mixture (a) SFC ttace (UV detection) (b) GC trace without heait-cut (100% transfer) (c) GC ti ace of heatt-cut fraction (flame-ionization detection used for GC experiments). Reprinted from Journal of High Resolution Chromatography, 10, J. M. Levy et al., On-line multidimensional supercritical fluid chromatography/capillaiy gas cluomatography , pp. 337-341, 1987, with permission from Wiley-VCFI.
R. El Hairak, M. Calull, R. M. Marce and R Boirull, Determination of naphthalene-sulphonates in water by on-line ion-pair solid-phase exti action and ion-pair liquid cliro-matography with diode-airay UV detection , Int. J. Environ Anal. Chem. 69 295-305 (1998). [Pg.375]

Fig. 3-8. HPLC evaluation of a 250 x 4.6 mm i.d. analytical column packed with the selected dipep-tidic (5)-Glu-(5)-Leu-DNB CSP. Conditions mobile phase 20 % 2-propanol in hexane, flowrate 2.0 mL min, UV detection at 280 nm. (Reprinted with permission from ref. [86]. Copyright 1999, American Chemical Society.)... Fig. 3-8. HPLC evaluation of a 250 x 4.6 mm i.d. analytical column packed with the selected dipep-tidic (5)-Glu-(5)-Leu-DNB CSP. Conditions mobile phase 20 % 2-propanol in hexane, flowrate 2.0 mL min, UV detection at 280 nm. (Reprinted with permission from ref. [86]. Copyright 1999, American Chemical Society.)...
Fig. 3-18. Selectivity factors a determined for (3,5-dinitroben-zoyl)leucine diallylamide on CSP 15-24. Conditions analyte (3,5-dinitrobenzoyl)leucine diallylamide column 150 x 4.6 mm i.d. mobile phase 20 % hexane in dichloromethane flowrate 1 mL min f UV detection at 254 nm. Fig. 3-18. Selectivity factors a determined for (3,5-dinitroben-zoyl)leucine diallylamide on CSP 15-24. Conditions analyte (3,5-dinitrobenzoyl)leucine diallylamide column 150 x 4.6 mm i.d. mobile phase 20 % hexane in dichloromethane flowrate 1 mL min f UV detection at 254 nm.
The reaction of ort/io-phthalaldehyde and a thiol compound with an amino acid to form an isoindole derivative can be used to enhance the detection sensitivity for the normally only weakly UV-detectable amino acid compounds, and to introduce an... [Pg.188]


See other pages where UV-detection is mentioned: [Pg.246]    [Pg.251]    [Pg.33]    [Pg.41]    [Pg.71]    [Pg.282]    [Pg.81]    [Pg.150]    [Pg.278]    [Pg.346]    [Pg.118]    [Pg.24]    [Pg.13]    [Pg.422]    [Pg.143]    [Pg.236]    [Pg.262]    [Pg.267]    [Pg.272]    [Pg.286]    [Pg.309]    [Pg.313]    [Pg.354]    [Pg.374]    [Pg.72]   
See also in sourсe #XX -- [ Pg.221 , Pg.230 , Pg.387 ]

See also in sourсe #XX -- [ Pg.98 , Pg.122 , Pg.126 , Pg.190 , Pg.223 ]

See also in sourсe #XX -- [ Pg.47 , Pg.48 ]

See also in sourсe #XX -- [ Pg.87 ]

See also in sourсe #XX -- [ Pg.179 ]

See also in sourсe #XX -- [ Pg.367 , Pg.544 , Pg.914 , Pg.918 ]

See also in sourсe #XX -- [ Pg.118 , Pg.180 ]

See also in sourсe #XX -- [ Pg.9 ]

See also in sourсe #XX -- [ Pg.237 , Pg.416 , Pg.471 , Pg.679 ]

See also in sourсe #XX -- [ Pg.691 ]

See also in sourсe #XX -- [ Pg.13 ]

See also in sourсe #XX -- [ Pg.36 ]

See also in sourсe #XX -- [ Pg.5 , Pg.6 , Pg.23 , Pg.24 , Pg.26 , Pg.62 , Pg.78 , Pg.79 , Pg.87 , Pg.88 , Pg.101 , Pg.126 , Pg.242 ]




SEARCH



Appendix UV detection using ion-pair reagents

Detection UV/VIS

Detection with 254-nm UV Light

High performance liquid chromatography UV detection

Indirect UV detection

Liquid Chromatography and UV Detection

Principles of UV Detection

Reversed-phase HPLC with UV detection

UV and fluorescence detection

UV detection cell

UV detection electrophoresis

UV detection limits

UV detection system

UV-absorption detection

UV-visible detection

UV/fluorescence detection

Ultra violet (UV) detection

© 2024 chempedia.info