User-adjustable control system

We use a simple liquid level controller to illustrate the concept of a classic feedback control system.1 In this example (Fig. 5.1), we monitor the liquid level in a vessel and use the information to adjust the opening of an effluent valve to keep the liquid level at some user-specified value (the set point or reference). In this case, the liquid level is both the measured variable and the controlled variable—they are the same in a single-input single-output (SISO) system. In this respect, the controlled variable is also the output variable of the SISO system. A system refers to the process which we need to control plus the controller and accompanying accessories such as sensors and actuators.2... [Pg.82]

The system can be controlled manually or by a S1MAT1C S7-300 (Siemens) control system. The latter configuration allows one to adjust all parameters by a user interface. To generate different programs all data can be stored, externally edited and loaded again to execute. All measured data are available online and they can also be stored, exported to an editable file or printed directly (Figure 4.27). [Pg.541]

During normal production with the force control system in operation as specified above, the tablet press will operate to maintain the constant compression force of 10 kN by adjusting the fill depth (Fig. 9). Most force control systems do not require the user to input the upper and lower force control limits for average compression force that are typically set by the manufacturer within tighter tolerances than those demanded by the weight requirements. The control system typically calculates the average compression force every revolution and compares it to the force set point. If the average measured compression force varies from... [Pg.3625]

The control system was written in VisualBasic to read the temperature of the PCR zone and adjust the heater and fans to follow a user-specified PCR temperature profile. The control system logic includes PID (proportional-derivative-integral) functionality /rrNote 4). In addition, the logic provides features to anticipate over or under-shoot following the temperature transitions to maximize control fidelity. The control program, implemented on a dedicated PC computer, drives the heater and fans via the... [Pg.446]

These controls represent the reference class of today s hot runner control systems, depending on the accuracy, functionality, ease of use, and adaptability. All control functions can be easily adapted to the Windows-like user interface. Fault analysis and diagnosis of the hot runner system are possible as well as master-slave configurations and loading of drawings or photos into the user-friendly touch-screen display for intuitive adjustment of the nozzles and hot runner block control areas. [Pg.396]

Power Supplies and Controls. Induction heating furnace loads rarely can be connected directiy to the user s electric power distribution system. If the load is to operate at the supply frequency, a transformer is used to provide the proper load voltage as weU as isolation from the supply system. Adjustment of the load voltage can be achieved by means of a tapped transformer or by use of a solid-state switch. The low power factor of an induction load can be corrected by installing a capacitor bank in the primary or secondary circuit. [Pg.127]

Research users need full access to the functional elements of the spectrometer system and require the most efficient and flexible tools for MR sequence and application development. If the measurement methods delivered with the software do not adequately address the specific investigational requirements of a research team, modem NMR software is an open architecture for implementing new and more sophisticated functionality, with full direct access to all hardware controlling parameters. After evaluation, the new functionality can be developed with the help of toolbox functions that allow rapid prototyping and final builds, to enable the new sequence to be executed by non-experienced personnel and then used in routine applications. These toolboxes provide application oriented definitions and connect to standard mechanisms and routine interfaces, such as the geometry editor, configuration parameters or spectrometer adjustments. [Pg.57]

The NovaScan is presented on a PC-compatible computer equipped with standard memory and visual capabilities, and is run on a DOS-based operating system. A customized response apparatus, including a joystick, control keys, and a keypad, is recommended. Trials of the tasks chosen to be included in the test system are displayed on the computer monitor in a random manner, thereby eliminating the need for the user to focus attention among simultaneously presented tests. However, divided attention components can be added, if needed. The length of the test (i.e., number of trials presented) can be adjusted based on the demands of the test environment. Performance is evaluated in an automated fashion using a change-from-baseline approach, and the test can be administered in an automated or supervisor-controlled manner. [Pg.120]

Otto Bock Sensor Hand provides secure grasps of various objects. The system frees the user from constant watch on the objects in the hand since the automatic grasping feature senses when an object is about to slip and makes necessary adjustments. The Flexi-Grip function gives the amputee a natural look and flexible grip. The hand is controlled by volitional contraction of muscles that are touching the socket. [Pg.1166]

With active systems, the controls are mostly automatic, heat flows are well contained, and heat transfer processes are accrrrately predictable. With passive systems, heat flows are more diffuse and complex interchanges occttr, which can be grossly influenced by user interference. Often the appropriate adjustment of controls (e.g., of shading devices or of Trombe-wall vents) by the user at the right time is reqtrired to achieve optimttm performance of the system. Both the competence and the attitude of the user can drastically influence the resrrlts. [Pg.231]

Machine builders usually use anchorless machinery mounting systems, or isolators, to level their machines. The isolators they use are adjustable to provide the means for precise and easy leveling. The isolators also have vibration control capabilities. To eliminate twist and to level with accuracy and ease, it is best for the end-user to install the machine on an isolator system as the machine builders did. [Pg.610]

The basic control strategy chosen is to adjust the cooling duration (within each cycle) based upon the measured values (provided hy the TCS). In order to make the system usable in as many situations as possible, flexibility has been provided to allow the user to configure numerous variants of this basic strategy. Regarding the cooling duration two cases can be handled ... [Pg.49]

The general Flexternal architecture described previously for the PUC and shown in. Figure 8, is also used for the Blank Cooling Control, where in this case the TCS provides the measurements. The user interface is an important component of the overall system. The design which has been developed is illustrated in. Figure 14, which shows the screen used for making adjustments to a particular section. This screen illustrates how the key capabilities needed for a practical control are provide As can be seen, the screen provides the ability to ... [Pg.50]


See other pages where User-adjustable control system is mentioned: [Pg.68]    [Pg.1179]    [Pg.723]    [Pg.791]    [Pg.35]    [Pg.1270]    [Pg.516]    [Pg.471]    [Pg.1244]    [Pg.14]    [Pg.95]    [Pg.362]    [Pg.57]    [Pg.356]    [Pg.406]    [Pg.426]    [Pg.144]    [Pg.122]    [Pg.222]    [Pg.79]    [Pg.466]    [Pg.1772]    [Pg.163]    [Pg.199]    [Pg.697]    [Pg.340]    [Pg.342]    [Pg.247]    [Pg.156]    [Pg.1018]    [Pg.1566]    [Pg.711]    [Pg.6]    [Pg.76]    [Pg.147]    [Pg.376]   