Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Cooling controlled

Zoning The practice of dividing a building into sections for heating and cooling control, in order to ensure that one controller is capable of dealing with ihc requirements of one zone alone. [Pg.1490]

Vega, A., Diez, F. and Alvarez, J.M., 1995. Programmed cooling control of a batch crystallizer. Computers and Chemical Engineering, 9, 471-476. [Pg.325]

LUBE OIL COOLING BLOCK COOLING CONTROL UNIT BASEPLATE... [Pg.151]

At present, defect-free silicon crystals have been achieved at only at diameters of 200 mm. Comparisons of crystal quality were made among three techniques a typical conventional Czrochralski crystal growth technique, a slow-cooled controlled reaction and the perfect silicon process. The quality levels achieved in D-defect levels of the material is... [Pg.336]

Interaction of the molten oxide and ammonia under nitrogen is rather violent and the mixture ignites. Use of a solvent and cooling controls the reaction to produce diamidophosphinic acid. [Pg.1880]

The objectives of fire suppression systems are to provide cooling, control the fire (i.e., prevent it from spreading) and provide extinguishment of the fire incident. A variety of fire suppression methods are available to protect a facility. Both portable and fixed systems can be used. The effectiveness of all fire extinguishing measures can be determined by the rate of flow of the extinguishing agent and the method or arrangements of delivery. [Pg.202]

This example allows the study of the interaction of chemical reaction with temperature influence. Various cooling control strategies can also be simulated. [Pg.305]

In Ballard s alliance with Ford, Volvo, and Daimler Chrysler, they will supply the other components of the vehicles from the car body to the electric motor drive. The fuel cell will function as the car s engine. It needs cooling, control and fuel processing. [Pg.269]

Greer, J. S., and S. S. Gross. 1980. The Practicality of Controlling Vapor Released from Spills of Volatile Chemicals through Cooling Control of Hazardous Material Spills. Proceedings of National Conference, pp. 130-133. Nashville, TN Vanderbilt University. [Pg.56]

Where water is involved in a PC, as in mold/die cooling controllers, with improper construction the most common problem (due to expansion/contraction not properly incorporated) is that water leaks occur. With their external pressure relief valves, they ensure discharge outside the cabinet. With inside discharge, severe damage can occur to mechanical and electrical components. [Pg.185]

Water-level and cooling control. When a water thermostat bath is operated for long periods, it is subject to loss of water by evaporation to a point that will interfere with its normal operation unless the water is replaced. Therefore the tank should have an overflow drain and should be provided with a continuous supply of cold water that can be controlled from a few drops per minute to a small, steady stream. This supply of water also performs an important control fimctiott A -hp motor delivers constantly about 37 W of mechanical energy to the bath, and on days when the room temperature is not far below the desired bath temperature, this amount of energy is itself sufficient to maintain the bath temperature above the desired level. A stream of cold water may compensate largely or entirely for the stirring heat. The adjustment of the water flow is often critical and must be checked frequently. [Pg.583]

Figure 9.30 Temperature profile for cooling controlled to minimize m 0f). Figure 9.30 Temperature profile for cooling controlled to minimize m 0f).
While these materials are held, either prior to release in inventory or in the manufacturing process itself, they must be held and handled so as not to contaminate the material itself, or other materials stored in the area. For example, heat sensitive materials may need to be stored in a cool, controlled (i.e., data-recorded) location. It is quite common in API manufacturing to store materials outdoors. This can be accomplished for specific materials as long as the requirements stated above are met. When brought into the manufacturing environment, the containers may require an additional cleaning. [Pg.259]

Valenta and Schrenk, in 1970, introduced a plasmajet which consisted of two separate chambers for the anode and the cathode. After ignition of the arc, these electrodes formed an angle of 30° to each other. The chambers were aluminium tubes (10 mm in diameter). At the upper ends were electrically isolated water-cooled control orifices, and at the other ends were water-cooled electrode supports. The aerosol sample was carried into the anode chamber with argon. Only argon flowed into the cathode chamber. [Pg.160]


See other pages where Cooling controlled is mentioned: [Pg.454]    [Pg.180]    [Pg.464]    [Pg.475]    [Pg.253]    [Pg.234]    [Pg.813]    [Pg.522]    [Pg.10]    [Pg.123]    [Pg.457]    [Pg.454]    [Pg.287]    [Pg.299]    [Pg.228]    [Pg.2911]    [Pg.390]    [Pg.307]    [Pg.457]    [Pg.324]    [Pg.216]    [Pg.227]    [Pg.55]    [Pg.101]    [Pg.366]    [Pg.527]    [Pg.416]    [Pg.40]    [Pg.124]   
See also in sourсe #XX -- [ Pg.250 ]




SEARCH



© 2024 chempedia.info