Flaving had over 150 years of technical development behind them, lead-acid batteries can be custom-tailored to specific applications, such as those requiring deep discharge cycles (e.g., where the batteries are used as the sole power source for electrical equipment) and for battery backup uses such as in large uninterruptible power supply systems in data centers. Moreover, lead-acid cells not only have low internal resistance but also experience no memory effect as do some more exotic cell designs, such as NiCads. This enables these cells to produce enormous currents and have a moderately long, predictable life.1... [Pg.1313]

Depending on the sensitivity of the calorimeter to temperature or voltage and other environment fluctuations, such influences should be eliminated. A temperature-controlled laboratory with a closed door and windows together with a mains voltage stabilizer or an uninterruptable power supply system is helpful in obtaining stable measuring conditions. [Pg.255]

Response time is the criterion for determining the system type. Types range from uninterruptible power supply systems that float on-line to power systems with no response time... [Pg.724]

Emergency or Uninterruptible Power Supply Facilities - Battery room exhaust systems (if unsealed batteries are present)... [Pg.148]

Restrooms, laboratories, and uninterruptible power supply (UPS) systems and battery rooms should have once through ventilation. Laboratories and battery rooms should only be accessed from the outside. [Pg.304]

With an available diesel emergency generator supplying power to critical pumps, the control room operators initiated shutdown procedures for the two reactor areas. An uninterruptible power supply (UPS) kept power to the DCS screens and instruments however, the DCS system was designed close all catalyst preparation and reactor feed valves on loss of power. Outside operators were sent to manually block in reactor feeds. [Pg.370]

Adequate alternative arrangements should be available for systems which need to be operated in the event of a breakdown. The time required to bring the alternative arrangements into use should be related to the possible urgency of the need. If the system fails or breaks down, the procedures to be followed should be defined and validated. Any failures and corrective actions taken should be recorded [13]. Special cases of breakdowns are power breakdowns. It is required that some computer systems work for 24 h and should not be interrupted after starting data acquisition. Consequently, an extra uninterruptible power supply (UPS) is required to allow the operation of these computerized systems during power breakdowns. [Pg.833]

Smaller fuel cells (1 kW and lower) may be used as portable power as well as back-up power (uninterruptible power supply) or as battery chargers. Small fuel cells are also being developed as battery replacement which would enable longer operation time for consumer electronics (such as laptop computers, cell phones, cameras, and music players). There is a wide array of possible fuel cell applications in military battery chargers, telecommunications, navigation systems, soldier power, computers, various power tools,... [Pg.119]

The bank needed to maximize the availability of its computer system to protect existing clients while attracting new ones. A traditional system, combining an uninterruptible power supply (ups) with power from the electric grid and backup diesel generators, would have more than a 63 percent probability of a major failure over its 20-year life. The SurePower system has less than a 1 percent chance of a major failure in 20 years. This may well be the difference between business success or bankruptcy. [Pg.15]

The average uninterruptible power supply (ups)/generator/ utility system has an availability of about 3-nines, explained Thomas Ditoro, the project s electrical engineer. The statistical term availability is industry jargon meaning the fraction of time the system is available for use.8 A system available 99.9 percent of the time is a 3-nines system, a system with 99.9999 percent availability is a 6-nines system, and so forth. The most redundant ups can achieve an availability of 4-nines. The fuel cell system at First National Bank of Omaha has a calculated availability of 6- to 7-nines. ... [Pg.53]

In industrial electronics, DLCs can be used in uninterruptible power supplies (UPS), elevators, pallet trucks, etc. [90], They can be combined into large modules with integrated balancing that span outages in all power categories. In power-electronic, they are particularly suitable for backup in operation independent of the line voltage. A particular example is the power supply of wind turbine pitch system which is a market which is increasing very fast. [Pg.460]

Stationary battery (cell) — Rechargeable -> batteries designed to be located at a fixed place. Stationary batteries are used mainly for uninterruptible power supplies (UPS) and standby applications. These cells are usually designed for high reliability and very long -> cycle life under shallow depth of discharge (DOD) conditions. The common chemical systems utilized for the production of stationary batteries are the -> lead-acid and -> nickel-cadmium batteries. Less common, and more futuristic is the - sodium-sulfur battery designed for KW and... [Pg.639]

System alarm/error messages Condition/readiness of business continuity measures Trip count for Uninterruptable Power Supplies (UPS)... [Pg.285]

Control of environmental conditions For systems that require a controlled environment, an SOP that defines the acceptable ranges of temperature, humidity, and power supply. Other environmental considerations may be what to do in the case of electrostatic discharges, power surges, fire, and lightning strikes, or the use and maintenance of an uninterruptible power supply (UPS). [Pg.492]

Electrical motor count, average size, substation and distribution system requirements, uninterruptable power supply requirements, etc. [Pg.147]

Note Alarm and intercommunication systems must be included in the electrical account. The cost may vary from 50K to 200K depending on the size of the plant. Material-labor split would be approximately 50-50. The uninterruptable power supply (UPS) must be included in the cost of the control room at 60K. [Pg.306]

A pharmaceutical plant can obtain emergency or standby electrical power from generators, rechargeable batteries, and in rare cases from a separate utility service. Uninterruptible power supplies, central storage battery system, and unit equipment all use rechargeable batteries for their emergency source of power. [Pg.1488]

In situations where it is not feasible to depend only on physical barriers, an isolation suite can be designed for working with these materials. Air locks and rooms that have negative differential pressure to the main hall ways are required, as well as HEPA-filtered inlet air and double-HEPA-filtered exhaust air. An uninterrupted power supply should be connected to the exhaust air handler to maintain a negative differential pressure if the suite is in operation during a power outage. If the exhaust air handler fails, all plant air handlers should be programmed to automatically turn off to minimize the potential for a positive differential pressure to develop. Each isolation suite may require a dedicated HVAC system.P l... [Pg.2883]


See other pages where Uninterruptible power supply systems is mentioned: [Pg.228]    [Pg.256]    [Pg.228]    [Pg.134]    [Pg.134]    [Pg.247]    [Pg.270]    [Pg.271]    [Pg.273]    [Pg.316]    [Pg.228]    [Pg.256]    [Pg.228]    [Pg.134]    [Pg.134]    [Pg.247]    [Pg.270]    [Pg.271]    [Pg.273]    [Pg.316]    [Pg.796]    [Pg.615]    [Pg.311]    [Pg.1078]    [Pg.219]    [Pg.18]    [Pg.80]    [Pg.340]    [Pg.173]    [Pg.338]    [Pg.399]    [Pg.95]    [Pg.95]    [Pg.620]    [Pg.190]    [Pg.1482]    [Pg.1488]    [Pg.2882]    [Pg.363]   
See also in sourсe #XX -- [ Pg.262 , Pg.313 , Pg.315 , Pg.324 ]




SEARCH



ESSENTIAL UNINTERRUPTIBLE POWER SUPPLY SYSTEM

Power Supply Systems

Power supplied

Power supplies

Power system

Uninterruptible power supply

Uninterruptible power system

© 2024 chempedia.info