Use uninterrupted power supply, where necessary, to allow time for orderly shutdown or time to get alternate power from reliable sources... [Pg.118]

Loads of rectifier, thyristor, UPS (uninterrupted power supply) and battery chargers etc. [Pg.505]

Unbalance, response programs, 372 Uninterruptable power supply (UPS), 311 Universal gas constant, 16 University of Virginia, 389 Unloader plug type, 81 plunger type, 81 port type, 81 valve, 81... [Pg.552]

Uninterrupted power supply for computers, initially only for central units, grew significantly with the introduction of personal computers (PCs) the batteries became smaller and, since they had to be located in offices, had to be in a sealed version, since no aggressive charging gases were permitted to escape. This advanced the breakthrough of the development of so-called recombination or valve-regulated... [Pg.255]

Flaving had over 150 years of technical development behind them, lead-acid batteries can be custom-tailored to specific applications, such as those requiring deep discharge cycles (e.g., where the batteries are used as the sole power source for electrical equipment) and for battery backup uses such as in large uninterruptible power supply systems in data centers. Moreover, lead-acid cells not only have low internal resistance but also experience no memory effect as do some more exotic cell designs, such as NiCads. This enables these cells to produce enormous currents and have a moderately long, predictable life.1... [Pg.1313]

Emergency or Uninterruptible Power Supply Facilities - Battery room exhaust systems (if unsealed batteries are present)... [Pg.148]

Power for the control panel should be provided with a suitable uninterrupted power supply (UPS). The panel will provide a DC current to field detectors. This power will enable the panel to monitor all input circuits, output circuits, and trouble signals within the detectors, such as shorts, ground faults, and detector disconnects. It will also provide an AC powering signal to field output devices. All output circuits should be similarly supervised for trouble. An example alarm and detection control panel is shown in Figure 7-18. [Pg.185]

Hydrogen gas may accumulate in rooms or areas where multiple batteries are routinely recharged or maintained, such as electric fork-lift truck charg-ing/maintenance stations and storage battery banks for Uninterruptible Power Supplies (UPS). Adequate continuous ventilation (natural or active) should be provided (CCA, 1992 NFPA 50A, 1999 NFPA 506, 1999). [Pg.250]

Restrooms, laboratories, and uninterruptible power supply (UPS) systems and battery rooms should have once through ventilation. Laboratories and battery rooms should only be accessed from the outside. [Pg.304]

With an available diesel emergency generator supplying power to critical pumps, the control room operators initiated shutdown procedures for the two reactor areas. An uninterruptible power supply (UPS) kept power to the DCS screens and instruments however, the DCS system was designed close all catalyst preparation and reactor feed valves on loss of power. Outside operators were sent to manually block in reactor feeds. [Pg.370]

There is now a great interest in developing different kinds of fuel cells with several applications (in addition to the first and most developed application in space programs) depending on their nominal power stationary electric power plants (lOOkW-lOMW), power train sources (20-200kW) for the electrical vehicle (bus, truck and individual car), electricity and heat co-generation for buildings and houses (5-20 kW), auxiliary power units (1-100 kW) for different uses (automobiles, aircraft, space launchers, space stations, uninterruptible power supply, remote power, etc.) and portable electronic devices (1-100 W), for example, cell phones, computers, camcorders [2, 3]. [Pg.4]

Efficiency of uninterruptible power supply (UPS) or safety power group (reaction delay, activity time)... [Pg.432]

Adequate alternative arrangements should be available for systems which need to be operated in the event of a breakdown. The time required to bring the alternative arrangements into use should be related to the possible urgency of the need. If the system fails or breaks down, the procedures to be followed should be defined and validated. Any failures and corrective actions taken should be recorded [13]. Special cases of breakdowns are power breakdowns. It is required that some computer systems work for 24 h and should not be interrupted after starting data acquisition. Consequently, an extra uninterruptible power supply (UPS) is required to allow the operation of these computerized systems during power breakdowns. [Pg.833]

Uninterrupted power supply (UPS) the length of the support during power failure and the power rating of the UPS... [Pg.144]

Nominal 3.6 V batteries have been designed for direct mounting on printed circuit boards for CMOS and NMOS memory support applications. Such cells are normally float charged from the main microcomputer DC power supply and constitute a form of uninterruptible power supply (UPS). [Pg.175]

Smaller fuel cells (1 kW and lower) may be used as portable power as well as back-up power (uninterruptible power supply) or as battery chargers. Small fuel cells are also being developed as battery replacement which would enable longer operation time for consumer electronics (such as laptop computers, cell phones, cameras, and music players). There is a wide array of possible fuel cell applications in military battery chargers, telecommunications, navigation systems, soldier power, computers, various power tools,... [Pg.119]

The bank needed to maximize the availability of its computer system to protect existing clients while attracting new ones. A traditional system, combining an uninterruptible power supply (ups) with power from the electric grid and backup diesel generators, would have more than a 63 percent probability of a major failure over its 20-year life. The SurePower system has less than a 1 percent chance of a major failure in 20 years. This may well be the difference between business success or bankruptcy. [Pg.15]

The average uninterruptible power supply (ups)/generator/ utility system has an availability of about 3-nines, explained Thomas Ditoro, the project s electrical engineer. The statistical term availability is industry jargon meaning the fraction of time the system is available for use.8 A system available 99.9 percent of the time is a 3-nines system, a system with 99.9999 percent availability is a 6-nines system, and so forth. The most redundant ups can achieve an availability of 4-nines. The fuel cell system at First National Bank of Omaha has a calculated availability of 6- to 7-nines. ... [Pg.53]

In industrial electronics, DLCs can be used in uninterruptible power supplies (UPS), elevators, pallet trucks, etc. [90], They can be combined into large modules with integrated balancing that span outages in all power categories. In power-electronic, they are particularly suitable for backup in operation independent of the line voltage. A particular example is the power supply of wind turbine pitch system which is a market which is increasing very fast. [Pg.460]

Since 1803, when Ritter invented the voltaic pile, rechargeable batteries have been known to exist [5]. The big breakthrough came in 1859, when Plante introduced the lead-acid battery [6]. Until today, this kind of secondary battery has been the most well-known electrochemical device. It is omnipresent in every car as a starter battery and also plays an important role in stationary energy storage (e.g. for uninterruptable power supplies). [Pg.228]

Stationary battery (cell) — Rechargeable -> batteries designed to be located at a fixed place. Stationary batteries are used mainly for uninterruptible power supplies (UPS) and standby applications. These cells are usually designed for high reliability and very long -> cycle life under shallow depth of discharge (DOD) conditions. The common chemical systems utilized for the production of stationary batteries are the -> lead-acid and -> nickel-cadmium batteries. Less common, and more futuristic is the - sodium-sulfur battery designed for KW and... [Pg.639]

Uninterruptible power supply — (UPS) Electronic power supply providing a safe and permanent source of electricity for devices needing a completely stable, uninterrupted supply of electricity (computers, major storage... [Pg.689]


See other pages where Uninterruptible power supplies is mentioned: [Pg.129]    [Pg.796]    [Pg.181]    [Pg.185]    [Pg.233]    [Pg.188]    [Pg.341]    [Pg.615]    [Pg.228]    [Pg.311]    [Pg.244]    [Pg.1078]    [Pg.386]    [Pg.235]    [Pg.219]    [Pg.29]    [Pg.18]    [Pg.22]    [Pg.80]    [Pg.340]    [Pg.188]    [Pg.173]    [Pg.338]    [Pg.399]    [Pg.95]    [Pg.88]    [Pg.2]   
See also in sourсe #XX -- [ Pg.1092 ]

See also in sourсe #XX -- [ Pg.449 ]

See also in sourсe #XX -- [ Pg.8 , Pg.327 , Pg.327 ]




SEARCH



ESSENTIAL UNINTERRUPTIBLE POWER SUPPLY SYSTEM

Power supplied

Power supplies

Uninterrupted Power Supply for Critical Loads

Uninterruptible power supplies, UPS

Uninterruptible power supply systems