Stable measurements

The four channel scanning system showed stable measurements up to 250 m/min drawing speed. At 300-350 m/min some measurements were unstable on two channels. At drawing velocities over 350 m/min measurements were unstable on all four channels. The four traces are better identified in colors on the computer screen than in this grey tone figure. [Pg.900]

If you cannot select suitable equipment for your current environment, you may need to control the environment in order to carry out the measurements. In such areas the environmental factors important to maintaining stable measurement should be monitored and the monitoring equipment calibrated. Chart recorders enable you to monitor conditions without having to be in constant attendance. The environment should be controlled in areas where calibration is carried out in order to provide stable conditions in which accurate and precise measurement can be taken. However, some modern equipment is so stable that environmental controls are unnecessary except in special circumstances. [Pg.420]

In contrast to the claim of Szwarc and co-workers 291) that the a-methyl(styryl)-sodium active center is stable, measurements from various sources have shown 293 30l) that transformations readily occur. The dimer structure formed froma-methyl styrene and sodium is as follows ... [Pg.68]

The Tg lesion rates among those ALS as shown with the help of an ODN containing this lesion at a specific position (Matray and Greenberg 1994). Interestingly, the FAPY-A lesion is readily identified as an ALS with this assay, while FAPY-G is not (Haraguchi et al. 2002). In the absence of piperidine but in the presence of phosphate buffer pH 7.5, the deglycosylation lifetime of FAPY-A is about 103 h at 37 °C FAPY-G is about 25 times more stable (measured at 55 °C Greenberg et al. 2001). [Pg.382]

Curie temperature Tc, from which we deduce a critical tolerance factor tc 0.955. The temperature dependence of the resistivity p (T) exhibits a strong maximum at Tc in the O phase as in Laoj-jcPL-CaojMnCh with x < 0.6, fig. 29 p(T) continues to increase with decreasing temperature below Ty in the O phase, and it was not possible to obtain a stable measure of a(T) below Ty in this phase. The maximum in a(T) occurs at a Tmax a little above Tc in the O phase. Five other features of fig. 30 are noteworthy. [Pg.294]

While reactor temperature often plays a dominant role on reaction rate, it is not the only contribution to the rate expression. We also have the influence of the concentrations of the reacting species as symbolized by / (.. in Eq. (4.5). This expression can range from simple to very complex. In the simplest form the rate of reaction is proportional to the reactant concentrations raised to their stoichiometric coefficients. This is true for an elementary step where it is assumed that the molecules have to collide to react and the frequency of collisions depends upon the number of molecules in a unit volume. In reality, matters are far more complicated. Several elementary steps with unstable intermediates are usually involved, even for the simplest overall reactions. When the intermediates are free radicals, there can be a hundred or more elementary steps. From an engineering viewpoint it is impractical to deal with scores of elementary steps and intermediates and we usually seek an overall rate expression in terms of the stable, measurable (in principle) components in the reactor. In theory we can derive... [Pg.78]

These simplifying assumptions allow elimination of some reaction steps, and representation of free radical and short-lived intermediates concentrations in terms of the concentration of the stable measurable components, resulting in complex non-mass action rate expressions. [Pg.14]

The ability of the current transducer to amplify low-current signals must be considered when choosing a potentiostat for SECM experiments. As a tip is miniaturized to nanometer dimensions, the accurate and stable measurement of SECM probe current becomes challenging. A 10 /xm diameter disk electrode produces about 2 nA of steady-state limiting current in a 1 mM solution of mediator, but a 10 nm disk electrode would produce only 2 pA. In the... [Pg.31]

The extent of reducing ion species present can be collectively measured as the Eh. Oxidation involves the loss of electrons, while the process of reduction can be viewed as the gaining of electrons. In order to maintain electrical neutrality overall, it is clear that the oxidation of one species must be accompanied by the reduction of another somewhere in the system hence, the concept of redox - the simultaneous occurrence of reduction and oxidation. In practice, a chemically inert electrode such as platinum or gold is used, which can transfer electrons to or from the environment. The potential developed is measured relative to a standard cell which itself is calibrated relative to the standard hydrogen electrode. Although measurement of Eh can be problematic, relatively stable measurements can be obtained using permanently installed electrodes of platinum or gold whereas spot measurements should be avoided due to unstable and... [Pg.313]

Although it is accepted that atmospheric mercury burdens have increased substantially since the pre-industrial period, it is uncertain whether overall atmospheric mercury levels are currently increasing, decreasing, or remaining stable. Measurements of mercury over remote areas of the Atlantic Ocean show increasing levels up until 1990 and a decrease for the period 1990-1994 (Slemr 1996, Pirrone et al. 2000, Munthe et al. 2001). However, other measurements at remote sites in northern Canada and Alaska show deposition rates... [Pg.955]

The sample bed was loaded with a thin layer of a powder material, which amount was in the range from 15 to 20 mg. Quartz wool was used at the top and the bottom of the sample bed to keep the solid powder firmly packed. This is essential for a stable measurement. [Pg.23]

Typically, two photodetectors are used in optical instrumentation because it is often necessary to include a separate reference detector to track fluctuations in source intensity and temperature. By taking a ratio between the two detector readings, whereby a part of the light that is not affected by the measurement variable is used for correcting any optical variations in the measurement system, a more accurate and stable measurement can be obtained. [Pg.93]

Caution should also be exercised when deciding upon the channel dimensions to be used for measurement. Larger channels result in a higher electric current that can be measured more easily, but the higher current implies that the effect of Joule heating is enhanced. This may lead to a less stable measurement condition. Typically, the smallest channel that still provides a voltage that is measurable with available equipment should be used. [Pg.3213]

Glass pH electrodes are convenient in the lab but are not well suited to longterm environmental measurements because electrode potentials drift We compensate for drift in the lab by frequent calibration in standard buffers. To monitor pH in natural waters, a spectrophotometer measures the ratio of absorbance of light at wavelengths corresponding to the two colored forms of an indicator. This ratio provides stable measurements without calibration. The precision (repeatability) of shipboard spectrophotometric pH measurements is 0.000 4 pH units. [Pg.188]

Depending on the sensitivity of the calorimeter to temperature or voltage and other environment fluctuations, such influences should be eliminated. A temperature-controlled laboratory with a closed door and windows together with a mains voltage stabilizer or an uninterruptable power supply system is helpful in obtaining stable measuring conditions. [Pg.255]

What do you think may be the reason for pH changes in small droplets under oil We have had the problem of acid contamination of oil, which could be removed by washing the oil with distilled water, after which stable measurements were obtained. [Pg.52]

In 2000 Jarvis etal. first applied FM-AFM in liquid and found that the extra sensitivity of the technique enabled them to make the first continuous and stable measurement of structured water. Having... [Pg.22]

The test piece of shin-bone is not a hnman shin-bone. It is a manipulated piece which has been cut out of a real human body and has been modified to such an extent that it is possible to prodnce stable measurements on it. Furthermore, it has been modified in such a way that only certain important features of it, which are related to some of its mechanical properties, have been controlled. The test shinbone, i.e. the research object, is a laboratory artifact. It is a non-fiivial problem how this object is related both to the real human shin-bone, as it exists in a living human being, and to the model object, which is the object that theories are about. Data are produced by making measurements on the research object, i.e. the test shin-bone, but they are interpreted as claims about the idealized model object. They are used to put blood and flesh on the Timoschenko beam, that is, data are reduced in such a way that they can be considered as statements about the dimensions and oscillations... [Pg.195]

In an acidic medium, orthophosphates form a yellow-coloured complex with molybdate ions. The combination of P, Sb and Mo leads after reduction with ascorbic acid to the formation of a very stable blue-coloured phosphormolybdenum complex. At a wavelength of 880 nm a very sensitive and stable measurement of P... [Pg.139]

Control charts may be utilized to monitor the variability of measurements from the quality control check standards and independent reference standards in order to optimally detect abnormal situations and ensure a stable measurement process. [Pg.937]


See other pages where Stable measurements is mentioned: [Pg.391]    [Pg.459]    [Pg.391]    [Pg.185]    [Pg.62]    [Pg.113]    [Pg.290]    [Pg.1399]    [Pg.1019]    [Pg.1192]    [Pg.1077]    [Pg.1566]    [Pg.61]    [Pg.220]    [Pg.140]    [Pg.151]    [Pg.320]    [Pg.1]    [Pg.550]    [Pg.83]    [Pg.233]    [Pg.152]    [Pg.1983]    [Pg.44]    [Pg.63]    [Pg.97]    [Pg.430]   
See also in sourсe #XX -- [ Pg.619 ]




SEARCH



Gases stable isotope ratio measurements

Stable isotope measurement

Stable isotope measurement 8-value

Stable isotope measurement mass spectrometry

Stable isotope natural abundance measurements

Stable isotope natural abundance measurements application

Stable isotopes measuring abundances

Volatile compounds stable isotope ratio measurements

© 2024 chempedia.info