For amines absorption in an acid solution, or preferably adsorption onto an acid ion exchange column (acidified divinylbenzene-styrenesulfonic acid copolymer) is used. 10-50 1 of ambient air is sent over a wet 100 mmx 3 mm I.D. column the ion exchange polymer is put into a vial, made alkaline and the water solution is analysed on packed Carbowax-KOH GC-column with a thermionic selective detector (TSD), which is specific for nitrogen- and phosphorus-compounds. Trimethylamine is detected easily at 1 ppb. [Pg.168]

The most common selective detectors in use generally respond to the presence of a characteristic element or group in the eluted compound. This is well illustrated by the thermionic ionisation detector (TID) which is essentially a flame ionisation detector giving a selective response to phosphorus- and/or nitrogen-containing compounds. Typically the TID contains an electrically heated rubidium silicate bead situated a few millimetres above the detector jet tip and below the collector electrode. The temperature of the bead is maintained... [Pg.243]

One great advantage of GC is the variety of detectors that are available. These include universal detectors, such as flame ionization detectors and selective detectors, such as flame photometric and thermionic detectors. The most generally useful detectors, excluding the mass spectrometer are described in the following sections. [Pg.201]

Hewlett-Packard Model 6890 gas chromatograph with capillary split/splitless inlet with HP5973 mass-selective detector equipped with an autosampler Shimadzu GC17A gas chromatograph with capillary split/splitless inlet with flame thermionic detector equipped with an AOC-17 autoinjector... [Pg.543]

Gas chromatograph fitted with a thermionic nitrogen-specific detector Gas chromatograph fitted with a quadrupole mass-selective detector... [Pg.1169]

Gas chromatographic methods have been successfully used for the determination of penicillin molecules bearing neutral side-chains in milk and tissues (95, 97), but cannot be used for amphoteric -lactams. Gas chromatography of penicillin residues is further complicated by the necessity for derivatization with diazomethane. This derivatization step is particularly important because it not only leads to formation of the volatile penicillin methyl esters but also improves their chromatographic properties (thermal stability and decreased polarity). Using a fused-silica capillary column in connection with a thermionic nitrogen-selective detector, excellent separation and sensitivity figures were obtained. [Pg.924]

The alkali flame-ionization detector, sometimes called an NP or nitrogen-phosphorus detector, contains a thermionic source, such as an alkali-metal salt or a glass element containing rubidium or other metal, that results in the efficient ionization of organic nitrogen and phosphorus compounds. It is a selective detector that shows little response to hydrocarbons. [Pg.837]

The successful application of the CFD method in combination with subsequent gas chromatographic separation and the use of an BCD has resulted in the extensive development of this technique. However, other CFD methods aimed at obtaining derivatives that can be selectively detected by other selective detectors (e.g., sodium thermionic, flame photometric) have not been developed adequately, despite their obvious promise. It seems that the high selectivity of the method should be used for the elaboration of selective methods of functional group analysis in order to identify compounds at the picogram level. This is especially pertinent to the analysis of microsamples on capillary columns. [Pg.29]

The flame-based GC selective detectors derive their response from a specific flame emission (flame photometric detectors), or certain secondary ionization processes subsequent to the combustion in a flame (thermionic or alkali-flame detectors). Recent advances in the detector principles and their applications, as pertinent to biochemical uses, will now briefly be reviewed. [Pg.75]

The popularity of the BCD can be attributed to the high sensitivity to organohalogen compounds, which include many compounds of environmental interest, including polychlorinated biphenyls and pesticides. It is the least selective of the so-called selective detectors but has the highest sensitivity of any contemporary detector. The NPD or thermionic ionization or emission detector is a modified FID in which a constant supply of an alkali metal salt, such as rubidium chloride, is introduced into the flame. It is a detector of choice for analysis of organophosphorus pesticides and pharmaceuticals. The FPD detects specific luminescent emission originating from various excited state species produced in a flame by sulfur- and phosphorus-containing compounds. [Pg.1804]

A selective thermionic specific detector (TSD) was developed by Albert (107) but it is more commonly referred to as a nitrogen-phosphorous detector (NPD). It is basically an alkali FID. Figure 13.36 compares the TSD and the microcoulometric detector. More resolution is obtained through the TSD with elimination of the mixing in the transfer line, reactor tube, and titration cell of the... [Pg.699]

Other Detectors Two additional detectors are similar in design to a flame ionization detector. In the flame photometric detector optical emission from phosphorus and sulfur provides a detector selective for compounds containing these elements. The thermionic detector responds to compounds containing nitrogen or phosphorus. [Pg.570]

Analysis of methyl parathion in sediments, soils, foods, and plant and animal tissues poses problems with extraction from the sample matrix, cleanup of samples, and selective detection. Sediments and soils have been analyzed primarily by GC/ECD or GC/FPD. Food, plant, and animal tissues have been analyzed primarily by GC/thermionic detector or GC/FPD, the recommended methods of the Association of Official Analytical Chemists (AOAC). Various extraction and cleanup methods (AOAC 1984 Belisle and Swineford 1988 Capriel et al. 1986 Kadoum 1968) and separation and detection techniques (Alak and Vo-Dinh 1987 Betowski and Jones 1988 Clark et al. 1985 Gillespie and Walters 1986 Koen and Huber 1970 Stan 1989 Stan and Mrowetz 1983 Udaya and Nanda 1981) have been used in an attempt to simplify sample preparation and improve sensitivity, reliability, and selectivity. A detection limit in the low-ppb range and recoveries of 100% were achieved in soil and plant and animal tissue by Kadoum (1968). GC/ECD analysis following extraction, cleanup, and partitioning with a hexane-acetonitrile system was used. [Pg.181]

Shinohara et al. [299] have described a procedure based on gas chromatography for the determination of traces of two, three, and five-ring azarenes in seawater. The procedure is based on the concentration of the compounds on Amberlite XAD-2 resin, separation by solvent partition [300], and determination by gas chromatography-mass spectrometry with a selective ion monitor. Detection limits by the flame thermionic detector were 0.5-3.0 ng and those by gas chromatography-mass spectrometry were in the range 0.02-0.5 ng. The preferred solvent for elution from the resin was dichloromethane and the recoveries were mainly in the range 89-94%. [Pg.414]


See other pages where Thermionic selective detector is mentioned: [Pg.229]    [Pg.137]    [Pg.326]    [Pg.614]    [Pg.649]    [Pg.813]    [Pg.60]    [Pg.260]    [Pg.229]    [Pg.220]    [Pg.19]    [Pg.11]    [Pg.153]    [Pg.229]    [Pg.56]    [Pg.147]    [Pg.134]    [Pg.226]    [Pg.228]    [Pg.251]    [Pg.484]    [Pg.608]    [Pg.691]    [Pg.1899]    [Pg.1937]    [Pg.399]    [Pg.375]    [Pg.471]    [Pg.948]    [Pg.436]    [Pg.442]    [Pg.653]    [Pg.271]    [Pg.351]   