Thermal analysis models

One-Dimensional Fuel Cell Thermal Analysis Model... [Pg.494]

Thermal analysis models are useful for determining welding parameters that minimize the formation of crack-susceptible microstructures for specific applications, but their... [Pg.75]

To verify the results of the FE thermal analysis model experimental verifications are needed. This will be carried out relative to the benchmark part for which a DMLS mold has been made using the 50 microns powder. The mold has incorporated within it pressure and temperature sensors. The tool is built in a similar manner to a conventional injection mold, based on a standard 1730 steel material. Long run injection cycle tests were applied, using Kistler temperature and pressure verification [6]. [Pg.1559]

Antioxidants have been shown to improve oxidative stabiHty substantially (36,37). The use of mbber-bound stabilizers to permit concentration of the additive in the mbber phase has been reported (38—40). The partitioning behavior of various conventional stabilizers between the mbber and thermoplastic phases in model ABS systems has been described and shown to correlate with solubiHty parameter values (41). Pigments can adversely affect oxidative stabiHty (32). Test methods for assessing thermal oxidative stabiHty include oxygen absorption (31,32,42), thermal analysis (43,44), oven aging (34,45,46), and chemiluminescence (47,48). [Pg.203]

Polypropylene molecules repeatedly fold upon themselves to form lamellae, the sizes of which ate a function of the crystallisa tion conditions. Higher degrees of order are obtained upon formation of crystalline aggregates, or spheruHtes. The presence of a central crystallisation nucleus from which the lamellae radiate is clearly evident in these stmctures. Observations using cross-polarized light illustrates the characteristic Maltese cross model (Fig. 2b). The optical and mechanical properties ate a function of the size and number of spheruHtes and can be modified by nucleating agents. Crystallinity can also be inferred from thermal analysis (28) and density measurements (29). [Pg.408]

Thermal analysis is really no more diffieult than Ohm s Taw. There are similar parameters to voltage, resistanee, nodes, and branehes. For the majority of elee-tronie applieations, the thermal eireuit models are quite elementary and if enough is known of the thermal system, values ean be ealeulated in a matter of minutes. If one has a temperature-measuring probe, the thermal eomponents ean also easily be measured and ealeulated. [Pg.187]

A common feature in the models reviewed above was to calculate pressure and temperature distributions in a sequential procedure so that the interactions between temperature and other variables were ignored. It is therefore desirable to develop a numerical model that couples the solutions of pressure and temperature. The absence of such a model is mainly due to the excessive work required by the coupling computations and the difficulties in handling the numerical convergence problem. Wang et al. [27] combined the isothermal model proposed by Hu and Zhu [16,17] with the method proposed by Lai et al. for thermal analysis and presented a transient thermal mixed lubrication model. Pressure and temperature distributions are solved iteratively in a iterative loop so that the interactions between pressure and temperature can be examined. [Pg.120]

Thermal Analysis - Differential Scanning Calorimetry (DSC) and thermal gravimetric analysis (TGA) were used to characterize the thermal properties of the polymers synthesized. DSC analysis was performed on a Perkin-Elmer Differential Scanning Calorimeter, Model 2C with a thermal analysis data station. Thermal gravimetric analysis (TGA) was carried out on a DuPont thermal gravimeter, Model 951. From the DSC and TGA plots of poly (N-pheny 1-3,4-dimethylene-... [Pg.134]

Thermal analysis (DSC, TMA, TGA) was performed with either a Perkin-Elmer Model 2 or Model 4. [Pg.263]

In the microscopic analysis of CHF, researchers have applied classical analysis of the thermal hydraulic models to the CHF condition. These models are perceived on the basis of physical measurements and visual observations of simulated tests. The physical properties of coolant used in the analysis are also deduced from the operating parameters of the test. Thus the insight into CHF mechanisms revealed in microscopic analysis can be used later to explain the gross effects of the operating parameters on the CHF. [Pg.347]

The use of solid state NMR for the investigation of polymorphism is easily understood based on the following model. If a compound exists in two, true polymorphic forms, labeled as A and B, each crystalline form is conformationally different. This means for instance, that a carbon nucleus in form A may be situated in a slightly different molecular geometry compared with the same carbon nucleus in form B. Although the connectivity of the carbon nucleus is the same in each form, the local environment may be different. Since the local environment may be different, this leads to a different chemical shift interaction for each carbon, and ultimately, a different isotropic chemical shift for the same carbon atom in the two different polymorphic forms. If one is able to obtain pure material for the two forms, analysis and spectral assignment of the solid state NMR spectra of the two forms can lead to the origin of the conformational differences in the two polymorphs. Solid state NMR is thus an important tool in conjunction with thermal analysis, optical microscopy, infrared (IR) spectroscopy, and powder... [Pg.110]

Thermal Analysis. The DuPont Instruments Model 9900, computer controlled thermal analyzer and Model 951 TGA module were used in the experiments, using a gas flow rate of 100 cc/min. Experiments were performed in dynamic and isothermal mode using air and argon. [Pg.547]

Sealants obtained by curing polysulfide liquid polymers with aryl bis(nitrile oxides) possess stmctural feature of thiohydroximic acid ester. These materials exhibit poor thermal stability when heated at 60°C they soften within days and liquefy in 3 weeks. Products obtained with excess nitrile oxide degrade faster than those produced with equimolar amounts of reagents. Spectroscopic studies demonstrate that, after an initial rapid addition between nitrile oxide and thiol, a second slower reaction occurs which consumes additional nitrile oxide. Thiohydroximic acid derivatives have been shown to react with nitrile oxides at ambient temperature to form 1,2,4-oxadiazole 4-oxides and alkyl thiol. In the case of a polysulfide sealant, the rupture of a C-S bond to form the thiol involves cleavage of the polymer backbone. Continuation of the process leads to degradation of the sealant. These observations have been supported by thermal analysis studies on the poly sulfide sealants and model polymers (511). [Pg.104]

Let us return to our discussion of the prediction of ignition time by thermal conduction models. The problem reduces to the prediction of a heat conduction problem for which many have been analytically solved (e.g. see Reference [13]). Therefore, we will not dwell on these multitudinous solutions, especially since more can be generated by finite difference analysis using digital computers and available software. Instead, we will illustrate the basic theory to relatively simple problems to show the exact nature of their solution and its applicability to data. [Pg.171]

Hofelich, T.C., J.B. Powers and D.J. Frurip 1994. "Determination of Compatibility via Thermal Analysis and Mathematical Modeling." Process Safety Progress 13(4) 227. October. [Pg.160]

Dong, H. B. and Hunt, J. D. (2001). A numerical model for two-pan heat flux DSC. Journal of Thermal Analysis and Calorimetry. 64,167-176. [Pg.262]

Resin Analysis. Thermal analysis of the BCB resin systems included Differential Scanning Calorisietry (DSC) using a DuPont 010 cell and Thermal Gravimetric Analysis (TGA) run on a DuPont 951 TGA, the entire thermal analysis system run using an Omnitherm model 35053... [Pg.368]

The chemical analyses were done by a combination of wet chemical, atomic absorption (Hitachi Z-800) and ICP (JY-38 VHR) methods. The crystalline phase identification was carried out by XRD (Philips PW-1710 Cu K scanning electron microscopy (Cambridge, Stereoscan 400), thermal analysis (Netsch, Model STA 490), ESR... [Pg.44]

Harsta A (1997) Thermodynamic modelling of CVD of high-T-c superconductors. Journal of Thermal Analysis 48(5), 1093-1104... [Pg.226]

DDI DISSOL DLM DLVO DOC DOE DTA DU Distilled, deionized water Thermodynamic simulation model Diffuse layer model named after Derjaguin, Landau, Vervey, Overbeek Dissolved organic carbon Department of Energy Differential thermal analysis Depleted uranium... [Pg.682]

TGA. Thermogravimetric analysis (TGA) and differential thermal analysis (DTA) are other means to confirm the above structural models. Figure 4.4.8 shows the thermal analysis data for sample I. Curve (a) shows a TG datum of a mass loss about 22% after heating over 350°C. The derivative curve (b) of mass loss curve (a) clearly shows that there are at least four steps during the decomposition of the sample. This finding was further confirmed by the DTA data curve (c) shown in the same figure. It is clearly seen that there are four endothermic peaks. The DTA and TGA curves were similar for all samples. Note that the relative ratios of mass... [Pg.318]

Differential scanning calorimetry is primarily used to determine changes in proteins as a function of temperature. The instrument used is a thermal analysis system, for example a Mettler DSC model 821e. The instrument coupled with a computer can quickly provide a thermal analysis of the protein solution and a control solution (no protein). The instrument contains two pans with separate heaters underneath each pan, one for the protein solution and one for the control solution that contains no protein. Each pan is heated at a predetermined equal rate. The pan with the protein will take more heat to keep the temperature of this pan increasing at the same rate of the control pan. The DSC instrument determines the amount of heat (energy) the sample pan heater has to put out to keep the rates equal. The computer graphs the temperature as a function of the difference in heat output from both pans. Through a series of equations, the heat capacity (Cp) can be determined (Freire 1995). [Pg.157]

Differential Thermal Analysis. High temperature differential thermal analyses were obtained with a Dupont Model 1200 instrument. Samples were heated from room temperature to 950° C at a rate of 20°C/min in a slow stream of hydrogen. Molybdenum cups were used to hold the sample and alumina reference. The instrument was calibrated with sodium chloride (mp 800° C). [Pg.383]


See other pages where Thermal analysis models is mentioned: [Pg.335]    [Pg.76]    [Pg.335]    [Pg.76]    [Pg.272]    [Pg.340]    [Pg.226]    [Pg.1098]    [Pg.120]    [Pg.175]    [Pg.50]    [Pg.23]    [Pg.74]    [Pg.51]    [Pg.58]    [Pg.148]    [Pg.250]    [Pg.117]    [Pg.254]    [Pg.376]    [Pg.146]    [Pg.453]    [Pg.271]    [Pg.456]    [Pg.205]    [Pg.47]   
See also in sourсe #XX -- [ Pg.75 ]




SEARCH



Model analysis

One-Dimensional Fuel Cell Thermal Analysis Model

Thermal modeling

Thermal modelling

Thermal stresses Stress analysis models