Temperature Control Units

The reactor in Fig. 5 operates as follows. A feed solution containing a given concentration of pollutant is pumped to the adsorbent module at a fixed volumetric flow rate. The module is kept isothermal by a temperature control unit, such as a surrounding water bath. Finally, the concentration of the outlet solution is measured as a function of time from when the feed was introduced to the adsorbent module. These measurements are often plotted as breakthrough curves. Example breakthrough curves for an aqueous acetone solution flowing... [Pg.107]

Control of the temperature of rubber compound whilst being processed in extruders and injection moulding machines is vital if the product from these processes is to be uniform in quality. Failure to control temperatures in processing equipment can lead to scorching of the compound as it emerges from the extruder die or injection machine nozzle. Most modem items of processing equipment are fitted to a temperature control unit using either oil or water as the circulatory medium. [Pg.201]

Figure 5 Temperature-dependent turbidimetry profiles for solutions of poly(Lys-25) at pH 7.0 and 11.0. These measurements were performed on a Pharmacia Biotechnology Ultrospec 3000 UV/visible spectrophotometer equipped with a programmable Peltier cell and temperature control unit. Figure 5 Temperature-dependent turbidimetry profiles for solutions of poly(Lys-25) at pH 7.0 and 11.0. These measurements were performed on a Pharmacia Biotechnology Ultrospec 3000 UV/visible spectrophotometer equipped with a programmable Peltier cell and temperature control unit.
Thermoelectric coolers find three basic categories of applications. (1) Use in electronic components (2) in temperature control units and (3) in medical and laboratory instruments. [Pg.1608]

The high-pressure cells and temperature control units are similar to the ones described by Betts and Bright (29). Samples for analysis were prepared by directly pipetting the appropriate amount of stock solution into the cell. To remove residual alcohol solvent, the optical cell was placed in a heated oven (60 °C) for several hrs. The cell was then removed from the oven, connected to the high-pressure pumping system (29), and a vacuum (50 pm Hg) maintained on the entire system for 10-15 minutes. The system was then charged with CF3H and pressurized to the desired value with the pump (Isco, model SFC-500). Typically, we performed experiments at 10 /xM PRODAN and there was no evidence for primary or secondary interfilter effects. HPLC analysis of PRODAN subjected to supercritical solvents showed no evidence of decomposition or additional components. [Pg.53]

Nonisothermal systems are accounted for by the introduction of temperature-control units into the generic reactor unit representation. These units consist of elements associated with the manipulation of temperature changes and constitute temperature profiles (profile-based approach) and heaters/coolers (unit-based approach). The assumption of thermal equilibrium between the contacting phases reduces the need for a single temperature per shadow reactor compartment. The profile-based system (PBS) finds the optimum profiles without considering the details of heat transfer mechanisms. Because the profiles are imposed rather than... [Pg.429]

Double-check that there is no stray light in the darkroom. This includes LEDs on timers and temperature control units. Then go through dry runs of the operation because you will be working in complete darkness. You will need to be able to adjust your exposure time for at least a 4-stop range in half-stop increments. I adjusted my setup to enable exposures (in seconds) of 4,6,8,12,16,23,30,45, and 60. [Pg.97]

Soil is placed into the clean dry cell. A 90-mm diameter Whatman filter paper is then placed on to the shoulder of the sample chamber and a clean steel filter placed on top of the filter paper. The top plate is screwed into the cell to contact the metal filter the temperature control unit cooler is then switched on. A small nominal stress (<1 MPa) needs to be applied to remove most of the air from the cell and to allow the sample and the components to bed in. When the selected temperature ( 2 C) is attained, the pressure can be increased and water collected. [Pg.236]

Figure 6 Schematic of a complete multiplexed and integrated instrumental design for PCR analysis with eight channels. Different functional capillaries were connected by a T-assembly and a cross-assembly. Stars represent the freeze/thaw valves V1 and V2. A syringe pump and a six-way selection valve were used to load and distribute liquids for various purposes. A CCD camera was used to collect fluorescence from the eight capillaries simultaneously. The temperature control unit at the cross-assembly was used to denature DNA prior to injection. (Reprinted from Ref. 34 with permission.)... Figure 6 Schematic of a complete multiplexed and integrated instrumental design for PCR analysis with eight channels. Different functional capillaries were connected by a T-assembly and a cross-assembly. Stars represent the freeze/thaw valves V1 and V2. A syringe pump and a six-way selection valve were used to load and distribute liquids for various purposes. A CCD camera was used to collect fluorescence from the eight capillaries simultaneously. The temperature control unit at the cross-assembly was used to denature DNA prior to injection. (Reprinted from Ref. 34 with permission.)...
The top layer is the procedural layer and this generally defines how unit operations are combined across plant units for the overall process. A feature of S88 is the ability to generate equipment modules, essentially common arrangements of control modules to provide a specific function (e.g., skid-mounted temperature control units for reactors or valve/pump arrangements for transfer routes). [Pg.644]

Equipment Model Generic Specifies the functionality of generic equipment modules such as temperature control units (TCUs)... [Pg.650]

Because the Influence of the temperature on monolayer properties may give relevant information (see fig. 3.8), it is desirable to have the trough equipped with a temperature-control unit. [Pg.221]

E-3 spectrometer. A servo-hydraulic system was built which allowed loading of the samples in a wide variety of modes, and permitted tensile tests to be conducted at constant stress rate, at constant stress (creep), in cyclic fatigue, at constant strain rate, at constant strain or step strain. Provision was made for the simultaneous recording of stress-strain data and ESR spectra and a variable temperature control unit was employed. [Pg.26]

A detailed account of a system developed for use with a Varian E-9 spectrometer is described by Mead and Reed A wide access cylindrical cavity was employed, which permitted a working zone 25 mm in diameter and 50 mm loi. Specially thin, vacuum insulated, double walled glassware was constmcted for use with the wide access cavity, as shown in Fig. 13. The Varian low temperature control unit was used in a similar manner to that shown in Fig. 12 placing the heater and temperature sens-... [Pg.26]

There are some problems that may be encountered when using cooling as a crystallization technique. While well-designed temperature control units ensure sufficient temperature control under many conditions, it is difficult to achieve... [Pg.99]

For materials applications, the chemical shifts of methanol and ethylene glycol can be monitored in the liquid state to follow temperature [Hawl]. The most sensitive ehemical shift is the Co resonance of aqueous Co(CN)e with a sensitivity of 0.05 K at 7 T and 0.2 K at 2T [Dorl]. Furthermore, dibromomethane dissolved in a liquid crystal is a temperature sensitive NMR compound [Hed 1 ], and known phase-transition temperatures can be exploited to calibrate the temperature control unit [Hawl J. In temperature imaging of fluids, temperature can be determined from the temperature dependence of the selfdiffusion coefficient but convective motion may arise in temperature gradients [Hedl]. In the solid state, the longitudinal relaxation time of quadrupolar nuclei like Br is a temperature sensitive parameter [Suil, Sui2]. In elastomers, both T2 and Ti depend on temperature (Fig. 7.1.13). In filled SBR, T2 is the more sensitive parameter with a temperature coefficient of about 30 xs/K [Haul]. [Pg.260]

Probe temperatures that are accurate and stable to better than 1 K are readily obtainable by this method using a suitable temperature-control unit. [Pg.235]

Implementing differential thermal analysis requires the following components (a) a circuit for measuring differences in temperature, (b) a heating device and temperature-control unit, (c) an amplifying and recording apparatus, and (d) an atmospheric-control device. [Pg.496]

Heating and Temperature Control. The heating and temperature-control units are very similar to those used in TG. Ovens should be constructed to avoid electrical interference with the thermocouples. To reduce this possibility even further, most instruments have an inner metallic chamber for the sample and reference, to act as... [Pg.498]

The similarities of TG and DTA are obviously great, at least instrumentally. As a consequence, many commercial instruments are designed to perform both types of analysis the heating device, temperature-control unit, atmospheric control, and recording device are essentially used in common and are contained in a single control unit, only the thermobalance and DTA sample compartments being separate. [Pg.499]

Physically, the magnet is small, 20 X 20 X 20 cm The temperature control unit can be considerably larger, depending on the temperature range and control desired. The RF electronics are usually contained within a personal computer. A RF pulse is used to excite the sample and the response of the sample is recorded as a function of time. [Pg.897]


See other pages where Temperature Control Units is mentioned: [Pg.139]    [Pg.273]    [Pg.92]    [Pg.167]    [Pg.201]    [Pg.139]    [Pg.273]    [Pg.265]    [Pg.150]    [Pg.147]    [Pg.270]    [Pg.838]    [Pg.234]    [Pg.272]    [Pg.272]    [Pg.273]    [Pg.982]    [Pg.49]    [Pg.570]    [Pg.523]    [Pg.169]    [Pg.51]    [Pg.186]    [Pg.48]    [Pg.170]    [Pg.474]    [Pg.144]   