Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Solution stock

The stock solution of quinoline-sulphur poison is prepared by refluxing I g. of sulphur with 6 g. of quinoline for 5 hours and diluting the resulting brown liquid to 70 nJ. with xylene which has been purified by distilling over anhydrous aluminium chloride. The addition of the quinoline - sulphur poison ensures that the reduction does not proceed beyond the aldehyde stage it merely slows up the reaction and has no harmful effects. [Pg.700]

Kinetic measurements were performed employii UV-vis spectroscopy (Perkin Elmer "K2, X5 or 12 spectrophotometer) using quartz cuvettes of 1 cm pathlength at 25 0.1 C. Second-order rate constants of the reaction of methyl vinyl ketone (4.8) with cyclopentadiene (4.6) were determined from the pseudo-first-order rate constants obtained by followirg the absorption of 4.6 at 253-260 nm in the presence of an excess of 4.8. Typical concentrations were [4.8] = 18 mM and [4.6] = 0.1 mM. In order to ensure rapid dissolution of 4.6, this compound was added from a stock solution of 5.0 )j1 in 2.00 g of 1-propanol. In order to prevent evaporation of the extremely volatile 4.6, the cuvettes were filled almost completely and sealed carefully. The water used for the experiments with MeReOj was degassed by purging with argon for 0.5 hours prior to the measurements. All rate constants were reproducible to within 3%. [Pg.123]

For the past year Strike had been in consultation with contract labs over the making of phenylisopropyl alcohols using sulfuric acid and allylbenzenes (don t ask). The lab owners would listen patiently as Strike primitively described how and why an OH should go on the beta carbon. And without exception, the lab owners would point out to Strike that the best way to get an OH on the beta carbon would be to put a Br there first. But Strike don t wanna put a Br there first Strike would say, Strike wants the OH put on directly using sulfuric acid " The lab guys had to do what Strike said because Strike was holding all the money (...a fool and her money etc.). But out of curiosity Strike asked how they would get that Br on the beta carbon. Every one of them said it was simply a matter of using the 48% HBr in acetic acid. They even showed Strike their stock solutions (usually from Aldrich or Fisher). [Pg.144]

X mL of 0.2M NaOH Added to 100 mL of Stock Solution (0.04M Acetic Acid, 0.04M H3PO4, and 0.04M Boric Acid)... [Pg.939]

Ethyl bis-(2,4-dinitrophenyl) acetate (indicator) the stock solution is prepared by saturating a solution containing equal volumes of alcohol and acetone with the indicator pH range colorless 7.4-9.1 deep blue. This compound is available commercially. The preparation of this compound is described by Fehnel and Amstutz, Ind. Eng. Chem., Anal. Ed. 16 53 (1944), and by von Richter, Ber. 21 2470 (1888), who recommended it for the titration of orange- and red-colored solutions or dark oils in which the endpoint of phenol-phthalein is not easily visible. The indicator is an orange solid which after crystallization from benzene gives pale yellow crystals melting at 150-153.5°C, uncorrected. [Pg.1191]

A stock solution is prepared by weighing out an appropriate portion of a pure solid or by measuring out an appropriate volume of a pure liquid and diluting to a known volume. Exactly how this is done depends on the required concentration units. For example, to prepare a solution with a desired molarity you would weigh out an appropriate mass of the reagent, dissolve it in a portion of solvent, and bring to the desired volume. To prepare a solution where the solute s concentration is given as a volume percent, you would measure out an appropriate volume of solute and add sufficient solvent to obtain the desired total volume. [Pg.30]

Solutions with small concentrations are often prepared by diluting a more concentrated stock solution. A known volume of the stock solution is transferred to a new container and brought to a new volume. Since the total amount of solute is the same before and after dilution, we know that... [Pg.31]

A laboratory procedure calls for 250 mb of an approximately 0.10 M solution of NH3. Describe how you would prepare this solution using a stock solution of concentrated NH3 (14.8 M). [Pg.31]

Balances, volumetric flasks, pipets, and ovens are standard pieces of laboratory instrumentation and equipment that are routinely used in almost all analytical work. You should be familiar with the proper use of this equipment. You also should be familiar with how to prepare a stock solution of known concentration, and how to prepare a dilute solution from a stock solution. [Pg.33]

M stock solution provides the smallest overall uncertainty ... [Pg.69]

I. 000 X 10- 1.000 X 10-k 1.000 X 10-k and 1.000 X 10- M from a 0.1000 M stock solution. Calculate the uncertainty for each solution using a propagation of uncertainty, and compare to the uncertainty if each solution was prepared by a single dilution of the stock solution. Tolerances for different types of volumetric glassware and digital pipets are found in Tables 4.2 and 4.4. Assume that the uncertainty in the molarity of the stock solution is 0.0002. [Pg.131]

The majority of titrations involving basic analytes, whether conducted in aqueous or nonaqueous solvents, use HCl, HCIO4, or H2SO4 as the titrant. Solutions of these titrants are usually prepared by diluting a commercially available concentrated stock solution and are stable for extended periods of time. Since the concentrations of concentrated acids are known only approximately,the titrant s concentration is determined by standardizing against one of the primary standard weak bases listed in Table 9.7. [Pg.298]

Procedure. Prepare a set of external standards containing 0.5 g/L to 3.0 g/L creatinine (in 5 mM H2SO4) using a stock solution of 10.00 g/L creatinine in 5 mM H2SO4. In addition, prepare a solution of 1.00 x 10 M sodium picrate. Pipet 25.00 mL of 0.20 M NaOH, adjusted to an ionic strength of 1.00 M using Na2S04, into a thermostated reaction cell at 25 °C. Add 0.500 mL of the 1.00 x 10 M picrate solution to the reaction cell. Suspend a picrate ion-selective electrode in the solution, and monitor the potential until it stabilizes. When the potential is stable, add 2.00 mL of a... [Pg.632]

There are three general types of radiopharmaceuticals elemental radionucHdes or simple compounds, radionucHde complexes, and radiolabeled biologically active molecules. Among the first type are radionucHdes in their elemental form such as Kr and Xe or Xe, and simple aqueous radionucHde solutions such as or I-iodide, Tl-thaUous chloride, Rb-mbidium(I) chloride [14391-63-0] Sr-strontium(II) chloride, and Tc-pertechnetate. These radiopharmaceuticals are either used as obtained from the manufacturer in a unit dose, ie, one dose for one patient, or dispensed at the hospital from a stock solution that is obtained as needed from a chromatographic generator provided by the manufacturer. [Pg.477]

Benzoic acid is suppHed to this market in the form of salts because the benzoate salts have a high solubiUty in water and aqueous stock solutions of up to 35% can easily be prepared. In addition, it is easier, and therefore cheaper, to purify sodium and potassium benzoate than to produce the USP/FCC grade of benzoic acid. [Pg.56]

Aqueous solutions of citric acid make excellent buffer systems when partially neutralized because citric acid is a weak acid and has three carboxyl groups, hence three p-K s. At 20°C pifj = 3.14, pi 2 4.77, and = 6.39 (2). The buffer range for citrate solutions is pH 2.5 to 6.5. Buffer systems can be made using a solution of citric acid and sodium citrate or by neutralizing a solution of citric acid with a base such as sodium hydroxide. In Table 4 stock solutions of 0.1 Af (0.33 N) citric acid are combined with 0.1 Af (0.33 N) sodium citrate to make a typical buffer solution. [Pg.179]

HR-ICP-MS EEEMENT-2 (Pinnigan MAT, Germany) equipped with a standard introduction system (quartz water-cooled spray chamber, concentric nebulizer, torch with 1.5 mm i.d. injector and nickel cones) was used for measurements. The following operating conditions were used RP power 1150 W, coolant gas flow rate 16 1 min k auxiliary gas flow rate 0.85 1 min nebulizer gas flow rate 1.2 1 min k Sample uptake rate was 0.8-1 ml min k Measurements were performed with low and middle resolutions. Rh was used as an internal standard. Por calibration working standard solutions were prepared by diluting the multielemental stock solutions CPMS (SPEX, USA) with water to concentration range from 5 ng to 5 p.g I k... [Pg.287]

When solution must be pumped, consideration should be given to use of holding tanks between the dry feed system and feed pumps, and the solution water supply should be controlled to prevent excessive dilution. The dry feeders may be started and stopped by tank level probes. Variable-control metering pumps can then transfer the alum stock solution to the point of application without further dilution. Means should be provided for calibration of the chemical feeders. Volumetric feeders may be mounted on platform scales. Belt feeders should include a sample chute and box to catch samples for checking actual delivery with set delivery. Gravimetric feeders are usually furnished with totalizers only. Remote instrumentation is frequently used with gravimetric equipment, but seldom used with volumetric equipment. [Pg.95]


See other pages where Solution stock is mentioned: [Pg.66]    [Pg.67]    [Pg.155]    [Pg.155]    [Pg.156]    [Pg.194]    [Pg.143]    [Pg.1184]    [Pg.1185]    [Pg.1186]    [Pg.1195]    [Pg.30]    [Pg.30]    [Pg.31]    [Pg.33]    [Pg.34]    [Pg.69]    [Pg.108]    [Pg.399]    [Pg.451]    [Pg.457]    [Pg.576]    [Pg.656]    [Pg.779]    [Pg.10]    [Pg.476]    [Pg.374]    [Pg.164]   
See also in sourсe #XX -- [ Pg.62 ]

See also in sourсe #XX -- [ Pg.26 , Pg.143 , Pg.309 ]

See also in sourсe #XX -- [ Pg.48 ]

See also in sourсe #XX -- [ Pg.305 ]

See also in sourсe #XX -- [ Pg.31 ]

See also in sourсe #XX -- [ Pg.95 ]

See also in sourсe #XX -- [ Pg.170 ]

See also in sourсe #XX -- [ Pg.29 , Pg.336 , Pg.337 , Pg.373 , Pg.376 ]

See also in sourсe #XX -- [ Pg.170 ]

See also in sourсe #XX -- [ Pg.96 ]

See also in sourсe #XX -- [ Pg.488 , Pg.488 ]

See also in sourсe #XX -- [ Pg.149 ]

See also in sourсe #XX -- [ Pg.406 , Pg.406 ]

See also in sourсe #XX -- [ Pg.29 , Pg.32 ]

See also in sourсe #XX -- [ Pg.96 ]

See also in sourсe #XX -- [ Pg.117 ]

See also in sourсe #XX -- [ Pg.100 , Pg.101 ]

See also in sourсe #XX -- [ Pg.64 ]

See also in sourсe #XX -- [ Pg.57 , Pg.71 , Pg.72 , Pg.83 , Pg.87 , Pg.128 , Pg.183 , Pg.186 , Pg.198 , Pg.201 , Pg.202 , Pg.316 , Pg.352 , Pg.411 , Pg.412 ]

See also in sourсe #XX -- [ Pg.112 , Pg.115 ]




SEARCH



Acetic acid diluting stock solution

Ammonium persulfate, solution preparation stock

DNase I stock solutions

Digitonin stock solution preparation

Dilution stock solution preparation

Dimethyl sulfoxide , solubility DMSO stock solutions

Element stock solutions, preparation

Ethidium bromide stock solution

H2S stock solutions

Hepes, solution preparation stock

Hydrochloric acid stock solution

Native stock solutions

Nitric acid stock solution

Oligonucleotides stock solutions

Original stock solution

Phenolic acid stock solutions

Phosphate-buffered saline, solution preparation stock

Preparation of Stock Solution

Preparation of Stock and Working Solutions

Primary stock solutions

Solutions stock solution

Solutions stock solution

Stability stock solution

Standard stock solutions

Stock Ammonium Sulfide Solution

Stock solution, preparation

Stock solutions, dilution

Sub-Stocks and Spiking Solutions

Sulfuric acid diluting stock solution

Sulfuric acid stock solution

Tris buffer, solution preparation stock

© 2024 chempedia.info