Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Suffering

Short-term exposure. This is the maximum concentration to which workers can be exposed for a period of up to 15 minutes continuously without suffering from (a) intolerable irritation, (b) chronic or irreversible tissue change, or (c) narcosis of sufficient degree to increase accident proneness, impair self-rescue, or materially reduce efficiency, provided that no more than four excursions per day are permitted, with at least 60 minutes between exposure periods, and provided the daily time-weighted value is not exceeded. [Pg.260]

The free radicals which have only a transient existence, like -CHa, C2H5 or OH, and are therefore usually met with only as intermediates in chemical reactions, can usually be prepared and studied directly only at low pressures of the order of 1 mm, when they may be transported from the place of preparation in a rapidly streaming inert gas without suffering... [Pg.181]

A quantitative theory of rate processes has been developed on the assumption that the activated state has a characteristic enthalpy, entropy and free energy the concentration of activated molecules may thus be calculated using statistical mechanical methods. Whilst the theory gives a very plausible treatment of very many rate processes, it suffers from the difficulty of calculating the thermodynamic properties of the transition state. [Pg.402]

Reservoirs containing low compressibility oil, having small amounts of dissolved gas, will suffer from large pressure drops after only limited production. If the expansion of oil is the only method of supporting the reservoir pressure then abandonment conditions (when the reservoir pressure is no longer sufficient to produce economic quantities of oil to the surface) will be reached after production of probably less than 5% of the oil initially in place. Oil compressibility can be read from correlations. [Pg.109]

The number of injectors required may be estimated in a similar manner, but it is unlikely that the exploration and appraisal activities will have included injectivity tests, of say water injection into the water column of the reservoir. In this case, an estimate must be made of the injection potential, based on an assessment of reservoir quality in the water column, which may be reduced by the effects of compaction and diagenesis. Development plans based on water injection or natural aquifer drive often suffer from lack of data from the water bearing part of the reservoir, since appraisal activity to establish the reservoir properties in the water column is frequently overlooked. In the absence of any data, a range of assumptions of injectivity should be generated, to yield a range of number of wells required. If this range introduces large uncertainties into the development plan, then appraisal effort to reduce this uncertainty may be justified. [Pg.214]

Outlet Superheater (SH) header of Unit 3 (600 MW. supercritical multi-fuel l of an ENEL power station it consists of 2 twin and independent bodies (22 m length, 488.5 mjn internal diameter, 76.2 mm thickness material SA 430 TP 321H stairdess steel). This header has suffered from relevant cracking problems in assembly welds after 108.000 hours of service and... [Pg.70]

This method suffers from two disadvantages. Since it measures 7 or changes in 7 rather than t directly, temperature drifts or adventitious impurities can alter 7 and be mistakenly attributed to changes in film pressure. Second, while ensuring that zero contact angle is seldom a problem in the case of pure liquids, it may be with film-covered surfaces as film material may adsorb on the slide. This problem can be a serious one roughening the plate may help, and some of the literature on techniques is summarized by Gaines [69]. On the other hand, the equipment for the Wilhelmy slide method is simple and inexpensive and can be just as accurate as the film balance described below. [Pg.114]

The preceding derivation, being based on a definite mechanical picture, is easy to follow intuitively kinetic derivations of an equilibrium relationship suffer from a common disadvantage, namely, that they usually assume more than is necessary. It is quite possible to obtain the Langmuir equation (as well as other adsorption isotherm equations) from examination of the statistical thermodynamics of the two states involved. [Pg.606]

Then it follows that the total number of collisions per unit time suffered by particles with all velocities is... [Pg.669]

We suppose that each particle in the small region suffers at most one collision during the time interval t, and calculate the change in f. [Pg.677]

Nonnal spontaneous Raman scahering suffers from lack of frequency precision and thus good spectral subtractions are not possible. Another limitation to this technique is that high resolution experiments are often difficult to perfomi [39]. These shortcomings have been circumvented by the development of Fourier transfomi (FT) Raman spectroscopy [40]. FT Raman spectroscopy employs a long wavelength laser to achieve viable interferometry. [Pg.1199]

Detection of cantilever displacement is another important issue in force microscope design. The first AFM instrument used an STM to monitor the movement of the cantilever—an extremely sensitive method. STM detection suffers from the disadvantage, however, that tip or cantilever contamination can affect the instrument s sensitivity, and that the topography of the cantilever may be incorporated into the data. The most coimnon methods in use today are optical, and are based either on the deflection of a laser beam [80], which has been bounced off the rear of the cantilever onto a position-sensitive detector (figme B 1.19.18), or on an interferometric principle [81]. [Pg.1693]

Dielectric constants of metals, semiconductors and insulators can be detennined from ellipsometry measurements [38, 39]. Since the dielectric constant can vary depending on the way in which a fihn is grown, the measurement of accurate film thicknesses relies on having accurate values of the dielectric constant. One connnon procedure for detennining dielectric constants is by using a Kramers-Kronig analysis of spectroscopic reflectance data [39]. This method suffers from the series-tennination error as well as the difficulty of making corrections for the presence of overlayer contaminants. The ellipsometry method is for the most part free of both these sources of error and thus yields the most accurate values to date [39]. [Pg.1887]


See other pages where Suffering is mentioned: [Pg.396]    [Pg.163]    [Pg.30]    [Pg.5]    [Pg.295]    [Pg.77]    [Pg.127]    [Pg.271]    [Pg.656]    [Pg.657]    [Pg.722]    [Pg.784]    [Pg.1015]    [Pg.686]    [Pg.502]    [Pg.664]    [Pg.669]    [Pg.678]    [Pg.811]    [Pg.1233]    [Pg.1656]    [Pg.1659]    [Pg.1660]    [Pg.1663]    [Pg.1781]    [Pg.1839]    [Pg.1839]    [Pg.1913]    [Pg.1973]    [Pg.1973]    [Pg.1977]    [Pg.2031]    [Pg.2105]    [Pg.2176]    [Pg.2186]    [Pg.2210]    [Pg.2269]    [Pg.2334]   
See also in sourсe #XX -- [ Pg.139 ]

See also in sourсe #XX -- [ Pg.283 , Pg.290 ]

See also in sourсe #XX -- [ Pg.15 , Pg.68 , Pg.88 , Pg.111 ]

See also in sourсe #XX -- [ Pg.437 ]

See also in sourсe #XX -- [ Pg.48 ]

See also in sourсe #XX -- [ Pg.119 ]

See also in sourсe #XX -- [ Pg.139 ]

See also in sourсe #XX -- [ Pg.175 ]

See also in sourсe #XX -- [ Pg.17 , Pg.29 , Pg.54 , Pg.59 , Pg.75 ]

See also in sourсe #XX -- [ Pg.26 , Pg.98 ]




SEARCH



Advertising sufferers

Oxidation Products Suffering Subsequent Reactions in Which PCC Plays no Role

Pain and suffering

Psychological Suffering

Suffer dioxide

Suffering choices made

Suffering universality

Voluntary suffering

© 2024 chempedia.info