Temperature drift

This method suffers from two disadvantages. Since it measures 7 or changes in 7 rather than t directly, temperature drifts or adventitious impurities can alter 7 and be mistakenly attributed to changes in film pressure. Second, while ensuring that zero contact angle is seldom a problem in the case of pure liquids, it may be with film-covered surfaces as film material may adsorb on the slide. This problem can be a serious one roughening the plate may help, and some of the literature on techniques is summarized by Gaines [69]. On the other hand, the equipment for the Wilhelmy slide method is simple and inexpensive and can be just as accurate as the film balance described below. [Pg.114]

When designing a system for thrust bearing proteetion, it is neeessary to monitor small ehanges in rotor axial movement equal to oil film thiekness. Probe system aeeuraey and probe mounting must be earefully analyzed to minimize temperature drift. Drift from temperature ehanges ean be unae-eeptably high. [Pg.170]

The analyzer contains three sensitive elements (thin films of zinc oxide) two elements are used in the measurements, whereas the third one is isolated hrom the atmosphere and serves to compensate for time and temperature drifts and to exclude the influence from molecular components of the environment. [Pg.256]

An ELSD converts the HPLC eluent into a particle stream and measures the scattered radiation. It offers universal detection for nonvolatile or semivolatile compounds and has higher sensitivity than the RI detector (in the low ng range) in addition to being compatible with gradient analysis. ELSD is routinely used in combinatorial screening. Response factors are less variable than that of other detectors. An ELSD consists of a nebulizer equipped with a constant temperature drift tube where a counter-current of heated air or nitrogen reduces the HPLC eluent into a fine stream of analyte particles. A laser or a polychromatic beam intersects the particle stream, and the scattered radiation is amplified by a photomultiplier. Manufacturers include Alltech, Polymer Laboratories, Shimadzu, Waters, Sedere, and ESA. [Pg.512]

A second improvement in Calvet s calorimeter is that a differential set-up was adopted that aimed to suppress temperature drifts and fluctuations of the heat sink. This was achieved by coupling two calorimetric units in opposition to each other, so the measured thermoelectric force was the difference between the thermoelectric forces of the sample cell and the reference cell. The latter may remain at the temperature of the thermostat while the heat output or input related to the event under investigation occurs in the sample cell. [Pg.140]

The detection limit is generally limited by electronic and mechanical noise, thermal drift, light source instabilities and chemical noise. But the intrinsic reference channel of the interferometric devices offers the possibility of reducing common mode effects like temperature drifts and non-specific adsorptions. Detection limit of 10 in refractive index (or better) can be achieved with these devices which opens the possibility of development of highly sensitive devices, for example, for in-situ chemical and biologically harmful agent detection. [Pg.132]

Common problems for pH measurements include potential or temperature drift, breakage of the electrode when it is handled, sluggish pH response, low value for the slope, and so on. Most pH meter manufacturers have provided quite intensive troubleshooting instructions in their instrument manual. Table 15.2 is a summary of some common solutions. [Pg.241]

A dry environment is required for the final tempering stage as liquid water on the outside of the NMR tube can be transferred to the coil and bias the measurement (as well as subsequent measurements taken from the contaminated coil). If a dry tempering block is unavailable, it may be possible to use a water bath if rapid and complete drying of the tube can be achieved before significant temperature drift has occurred. [Pg.568]

Abbreviations Me, methyl Et, ethyl Pr, n-propyl Bu, n-butyl Pe, n-pentyl He, n-hexyl Hep, n-heptyl Pic, picrate NS, naphtylsulfonate DS, dodecyl-sulfate. b Some samples show a temperature drift with time, so that Tc is only approximately given, or there are different samples with different Tc values within a series of measurements. For details we refer to the original papers. [Pg.13]

In many of the above polymers characteristic temperature drifts of the calorimeter were observed above and below Tg depending upon the previous thermal history of the sample. In the case of the synthetic rubber, GR-S, Rands,... [Pg.255]

Ferguson and Prather (1944) found that with rapidly cooled samples upward temperature drifts occurred in the calorimeter in the glass transition range while the opposite effect, namely downward temperature drifts, was observed in the case of slowly cooled, or carefully annealed samples. In Furukawa and Reilly s (1956) investigation of polyisobutylene, the shock-cooled samples exhibited upward temperature drifts below T and downward temperature drifts above T , while the annealed sample exhibited only downward temperature drifts above T . Furukawa, McCoskey and Reilly (1955) found similar drifts in the case of some butadiene-styrene copolymers. [Pg.255]

In terms of the hole theory, the opposite phenomenon, namely, the slow absorption of heat (negative temperature drifts of the calorimeter) have to be explained in the following way Assuming that the negative... [Pg.256]

There is no direct calorimetric evidence for any unusual phenomena exhibited by the liquid state, except possibly the negative temperature drifts in the neighborhood of Tg mentioned earlier. [Pg.260]

Although PZ gas chemosensors are susceptible to artefacts, like temperature drift as well as humidity and pressure changes, their essential virtues, consisting in... [Pg.229]

Experimental proof of control of the mask temperature with the chiller in a Gen 2 OVPD module under process conditions (showerhead heated to 325 °C) was achieved by in situ temperature measurement, as shown in Fig. 9.4. The experiments were performed at atmospheric pressure and at a deposition pressure of 0.9 mbar typical for OVPD, and for chiller temperatures between 5 and 30 °C. The mask temperature can be linearly controlled by the chiller temperature. The observed AT of 6.5 degrees is in good agreement with modeling prediction of 3 degrees in Fig. 9.3. In addition, measurements during a typical OVPD deposition time of 2 to 6 min confirmed there is no temperature drift under process conditions over time. The data prove that heat conductance and radiation is perfectly compensated by the chiller capacity. [Pg.206]

Fig. 3. The mobility coefficient K describing the movement of an ion swarm in an electric field. The mobility coefficient depends on the cross-section (collision area) ft, the reduced mass /i, and the effective temperature re f of the ion. Collision area ftD will depend on moisture, temperature, drift gas, and molecule. Fig. 3. The mobility coefficient K describing the movement of an ion swarm in an electric field. The mobility coefficient depends on the cross-section (collision area) ft, the reduced mass /i, and the effective temperature re f of the ion. Collision area ftD will depend on moisture, temperature, drift gas, and molecule.
Dielectric resonators are extensively used in mobile communications technology. As far as selectivity and temperature drift are concerned the requirements for hand-held units are far less demanding than for those used in the base stations, and for the more general filter applications. For example, for... [Pg.307]


See other pages where Temperature drift is mentioned: [Pg.195]    [Pg.79]    [Pg.300]    [Pg.160]    [Pg.81]    [Pg.81]    [Pg.310]    [Pg.71]    [Pg.127]    [Pg.74]    [Pg.215]    [Pg.83]    [Pg.89]    [Pg.154]    [Pg.147]    [Pg.288]    [Pg.520]    [Pg.181]    [Pg.223]    [Pg.243]    [Pg.255]    [Pg.257]    [Pg.242]    [Pg.227]    [Pg.247]    [Pg.376]    [Pg.116]    [Pg.120]    [Pg.121]    [Pg.47]    [Pg.402]   
See also in sourсe #XX -- [ Pg.81 ]