Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Standardizing fields

International Union for Pure and AppHed Chemistry (lUPAC) Bank Court Way, Cowley Centre Oxford 0X4 3YP United Kingdom Among its pubheations in the standards field are Manual of Symbols and Terminologyfor Physico-chemical Quantities and Units, D. H. Whiffen, ed., Pergamon, New York, 1979, and Nomenclature of Inorganic Chemisty, Pergamon, New York, 1977. [Pg.26]

The AMIE is different from the standard field ionization or evaporation. The emitted positive ion beams, with a flux of approximately 10 ions/sec, are obtained under ultra-high vacuum conditions (wl0 Torr). Due to the ultra-high vacuum, the observed ion beams cannot be due to the impurities in the vacuum chamber. Also, the beam is very difficult to deflect by an external magnetic field, indicating that they consist of heavy ions. Furthermore, the emitted ion beam is highly collimated, and form a sharp image of the tip... [Pg.290]

Most Infantry Artillery Weapons (Hoheiho) were characterized by their immobility, as very few of them were designed for rapid motor transport. The standard Field Piece (Yaho) was 75mm, although 105mm and 150mm were frequently encountered... [Pg.454]

Exercise 1.21 Show that multiplication of equivalence classes of functions (as defined in Section 1.7) is well defined. Show that addition and multiplication of equivalence classes of functions satisfy some but not all the standard field axioms (such as the distributive law, existence ofO, etc.). The list of field axioms is available in many texts, including [Ru76, Definition 1.12]. Which axioms hold, and which fail ... [Pg.40]

Kennedy, R.S. et al., Indexing cognidve tests to alcohol dosage and comparison to standardized field sobriety tests, J. Stud. Alcohol, 55, 615, 1994. [Pg.125]

The first term exists for er —> 0, with corrections of order a ln(<7 2). The second integral yields a contribution of order ln(cr 2). Since it is independent of p, Tj it can be absorbed into a redefinition of the vertex, i.e. into the first diagram of Fig. 11,1b. In standard field theoretic notation we write... [Pg.203]

The second equation poses no problem because 8 was defined as a phase function. If T) < 1, the solution for S is trivial, as the standard field with form. st then becomes a knot. The same happens if q is bounded, say, if q <4, because we can then take as the Clebsch variables q = q/ , 8 = n 8, where n is an integer greater than A. Dropping the primes and entering the new Clebsch variables in (144), it is clear that there then exists a solution for S, y. [Pg.237]

It means that standard field theory Hamiltonian of the form,... [Pg.88]

Comparability of environmental chemical data encompasses the concepts of precision, accuracy, and representativeness. Because accuracy and precision depend on the analytical procedure and representativeness depends on the sampling procedure, comparability is greatly affected by the sampling and analysis procedures used in data collection. For the data sets to be comparable, the samples must be collected and handled in a similar manner and the measurements must be obtained under the exact same analytical conditions. The observance of standard field and laboratory protocols and procedures, the use of EPA-approved or standard analytical methods and accepted QA/QC practices assure data comparability. [Pg.43]

The sampling crew is also responsible for obtaining field instruments and test kits, if required by the project scope. Field instruments should be calibrated prior to mobilization as a rule, they come with manufacturer s instruction manuals and calibration standards. Field test kits, which became widely used in the recent years, are also obtained in advance in sufficient quantity and of the quality specified in the SAP. Because different manufacturers make field instruments and test kits in different formats, members of the sampling crew may require special training in their use. [Pg.88]

Internal standard calibration is used when the changes in the analytical system are known to be frequent and substantial. To compensate for these changes, internal standards at known concentrations are added to all calibration standards, field samples, and laboratory QC samples prior to analysis. Internal standards are synthetic analogs of specific target compounds or compounds that are similar in nature to the target analytes and that are not found in environmental samples. Internal standard calibration is a requirement of GC/MS methods. Laboratories sometimes use it for GC methods as it significantly improves the accuracy of compound quantitation. [Pg.249]

Internal standards are brominated, fluorinated or stable isotopically labelled analogs of specific target compounds or other closely related compounds not found in environmental samples that are added to all standards, field, and laboratory QC samples as part of internal standard calibration procedure. The addition of internal standards takes place after the samples have been prepared and before they are analyzed. [Pg.261]

On the basis of laboratory and field results, the soluble acrylic system was chosen for further field trials. The formulation (code //1692) was tested on 210 hectares, 13 separate fields in Arizona and California during the 1982 growing season. Each test field was compared to a standard field, treated either with a chemical regime or a commercial pheromone product, located in the immediate vicinity. The efficacy assessment was based on trap catch reduction and boll infestation control. The treatment rate was 6.9 liters of formulation per hectare. This represented a rate of 3.7 grams pheromone and 36.9 grams pyrethroid per hectare. Treatment intervals were approximately ten days apart and the applications... [Pg.158]

The standard version of the susceptibility is immediately obtained from F through eqn (4.15), and from that equation, using the standard field factor theory for a single component system. [Pg.260]

What are the nonlinearities of the cold-atom gas The standard field-atom equations are highly nonlinear indeed, their nonlinearity is what gives rise to BIT in the first place. It is noteworthy that the creation of BIT also generates an oscillation in the density matrix component at the difference frequency between the pump and the probe fields ... [Pg.169]

This paper has presented a review of the various methods of monitoring dry deposition using surrogate surfaces, and has summarized data obtained using some of these surfaces. The lack of a standardized surface design and standardized field deployment procedures make comparison of the results obtained by the surfaces difficult. Nevertheless, the data show some consistencies deposition velocity increases with increasing MMD of depositing species, and there is a definite pattern when data for filter paper, flat plates, and Petri dishes are compared. [Pg.59]

The use of the ion microscope in adsorption studies is still in its infancy. It is therefore difficult to compare in detail the achievements of this technique with flash desorption or with the standard field emission microscope. At the moment the range of systems that can be fruitfully studied in the ion microscope is circumscribed by the high fields required for image formation, by field desorption of the adsorbed layer, as well as by electron bombardment. However, the tremendous power of the ion microscope for studies of adsorption is clearly apparent from the work already done, and further technical improvements should widen the range of applicability. [Pg.391]


See other pages where Standardizing fields is mentioned: [Pg.21]    [Pg.1316]    [Pg.147]    [Pg.158]    [Pg.926]    [Pg.91]    [Pg.413]    [Pg.206]    [Pg.144]    [Pg.345]    [Pg.354]    [Pg.83]    [Pg.27]    [Pg.31]    [Pg.103]    [Pg.112]    [Pg.237]    [Pg.240]    [Pg.241]    [Pg.236]    [Pg.208]    [Pg.431]    [Pg.253]    [Pg.301]    [Pg.103]    [Pg.179]    [Pg.88]    [Pg.234]    [Pg.615]    [Pg.111]    [Pg.292]    [Pg.213]   
See also in sourсe #XX -- [ Pg.292 ]




SEARCH



© 2024 chempedia.info