Research users need full access to the functional elements of the spectrometer system and require the most efficient and flexible tools for MR sequence and application development. If the measurement methods delivered with the software do not adequately address the specific investigational requirements of a research team, modem NMR software is an open architecture for implementing new and more sophisticated functionality, with full direct access to all hardware controlling parameters. After evaluation, the new functionality can be developed with the help of toolbox functions that allow rapid prototyping and final builds, to enable the new sequence to be executed by non-experienced personnel and then used in routine applications. These toolboxes provide application oriented definitions and connect to standard mechanisms and routine interfaces, such as the geometry editor, configuration parameters or spectrometer adjustments. [Pg.57]

The SEDOR method is based on subtraction of large signals leading to small signal differences. It is sensitive to small signal errors and critically depends on spectrometer adjustments. The HYCAT method is illustrated in Fig. 7.2.33(a) [Kim4]. The initial... [Pg.312]

Fig. 35. 3p doublet electron lines from Ar gas studied by means of Nel radiation. Light source and spectrometer adjusted for max resolving power of 5.7 meV. [Pg.275]

An example of a serial-recording EEL spectrometer is shown in Eig. 2.33 it features a magnetic prism system which was constructed for a TEM/STEM of the type JEOL JEM lOOS [2.199, 2.200]. Its second-order aberrations are corrected by curved pole-piece boundaries, an additional field clamp, and two extra hexapoles acting as stig-mators. The electron beam can be adjusted relative to the optical axis by use of several deflection coils. A magnetic round lens is positioned just in front of the prism to... [Pg.53]

Reduction of the measurement time for element distributions is possible by simultaneous detection of several masses. This can be achieved only by use of a magnetic sector field spectrometer with Mattauch-Herzog geometry [3.49] (Fig. 3.20) and parallel detection of up to five masses by mechanically adjusted electron multipliers. [Pg.117]

Ruonne NMR data can be collected readily on most spectrometers, requinng only minor adjustments to mstrumentation used to run proton samples The fluonne-19 nucleus is easily detected (relative abundance, 100%, spin, 1/2) and generates a wealth of spectral information to assist in structure elucidation To take full advantage of all the spectral evidence available, H, and chemical shifts and couphng constants should be acquired and correlated... [Pg.1040]

If evaporation is not complete, the majority of the liquid on the belt is not able to pass through the tunnel seals and this leads to a reduction in sensitivity. Any liquid that does pass through is likely to cause significant pressure fluctuations within the mass spectrometer and this will lead to inconsistent performance, particularly in respect of the sensitivity which is obtained. If the heat input can be adjusted to effect complete evaporation of the droplets, an erratic TIC trace is obtained, as discussed previously. [Pg.137]

Figure 4-8. Basic components of a simple mass spectrometer. A mixture of molecules is vaporized in an ionized state in the sample chambers.These molecules are then accelerated down the flight tube by an electrical potential applied to accelerator grid A. An adjustable electromagnet, E, applies a magnetic field that deflects the flight of the individual ions until they strike the detector, D.The greater the mass of the ion, the higher the magnetic field required to focus it onto the detector. Figure 4-8. Basic components of a simple mass spectrometer. A mixture of molecules is vaporized in an ionized state in the sample chambers.These molecules are then accelerated down the flight tube by an electrical potential applied to accelerator grid A. An adjustable electromagnet, E, applies a magnetic field that deflects the flight of the individual ions until they strike the detector, D.The greater the mass of the ion, the higher the magnetic field required to focus it onto the detector.
Complex peptide mixmres can now be analyzed without prior purification by tandem mass spectrometry, which employs the equivalent of two mass spectrometers linked in series. The first spectrometer separates individual peptides based upon their differences in mass. By adjusting the field strength of the first magnet, a single peptide can be directed into the second mass spectrometer, where fragments are generated and their masses determined. As the sensitivity and versatility of mass spectrometry continue to increase, it is displacing Edman sequencers for the direct analysis of protein primary strucmre. [Pg.27]

The kinetics of P-elimination were followed by the increase of the absorbance at 235 nm (Albersheim et al., 1960). The pH of the pectin solution (1 ml, already in the spectrometer) was adjusted at t = 0 by adding 1 ml of 0.2 M sodium hydrogenocarbonate sodium carbonate buffer. This buffer did not have a prohibitively high absorbance at 235 nm. [Pg.603]

X-ray Photoelectron Spectroscopy analysis of the samples was performed with a Surface Science Instruments spectrometer (SSI 100) with a resolution (FWHM Au 4f7/2) of 1.0 eV. The X-ray beam was a monochromatised AlKa radiation (1486.6 eV). A charge neutraliser (flood gun) was adjusted at an energy of 6 eV. As the Cls spectra of these compounds were very complex, the binding energies were referenced to the binding energy of Ols, considered experimentally to be at 531.8 eV [8). [Pg.78]

A Surface Science Instruments SSX-100 spectrometer (model 206), equipped with an aluminum anode whose radiation was monochromatized (AlKa, 1486.6 eV) and focalized, was used. The positive charge developed at the surface of the samples was compensated with a charge neutralizer adjusted at an energy of 8 eV. [Pg.99]

The partial pressures of the stable neutral molecules in the discharge (silane, hydrogen, disilane, trisilane) can be measured by a quadrupole mass spectrometer (QMS). The QMS usually is mounted in a differentially pumped chamber, which is connected to the reactor via a small extraction port [286]. In the ASTER system a QMS is mounted on the reactor that is used for intrinsic material deposition. The QMS background pressure (after proper bake-out) is between 10 and 10 mbar. The controllable diameter in the extraction port is adjusted so that during discharge operation the background pressure never exceeds 10"" mbar. [Pg.85]

The y-detector of a Mossbauer spectrometer converts the incident y-photons into electric output pulses of defined charge (see Sect. 3.1.6). The detector signals are electronically amplified and shaped by an amplifier network to obtain strong needle pulses with well-defined rise time, so that the pulse height is proportional to the energy of the incident photon. The amplifiers are usually adjusted to obtain... [Pg.35]

In summary, pulse-height analysis (PHA) prior to a Mossbauer measurement is an essential step in tuning a Mossbauer spectrometer. PHA allows the adjustment of the y-detection system to the Mossbauer photons and the reduction of noise by rejecting nonresonant background radiation. [Pg.37]

Adjustable Workbench (PAW) instrument assembly. The SH shown in Figs. 3.15 and 3.16 contains the electromechanical transducer (mounted in the center), the main and reference Co/Rh sources, multilayered radiation shields, detectors and their preamplifiers and main (linear) amplifiers, and a contact plate and sensor. The contact plate and contact sensor are used in conjunction with the IDD to apply a small preload when it places the SH holding it firmly against the target. The electronics board contains power supplies/conditioners, the dedicated CPU, different kinds of memory, firmware, and associated circuitry for instrument control and data processing. The SH of the miniaturized Mossbauer spectrometer MIMOS II has the dimensions (5 x 5.5 x 9.5) cm and weighs only ca. 400 g. Both 14.4 keV y-rays and 6.4 keV Fe X-rays are detected simultaneously by four Si-PIN diodes. The mass of the electronics board is about 90 g [36],... [Pg.55]


See other pages where Spectrometer adjustment is mentioned: [Pg.49]    [Pg.195]    [Pg.195]    [Pg.49]    [Pg.195]    [Pg.195]    [Pg.1330]    [Pg.1559]    [Pg.1561]    [Pg.1574]    [Pg.389]    [Pg.179]    [Pg.277]    [Pg.322]    [Pg.421]    [Pg.199]    [Pg.200]    [Pg.543]    [Pg.421]    [Pg.245]    [Pg.543]    [Pg.224]    [Pg.170]    [Pg.35]    [Pg.118]    [Pg.119]    [Pg.190]    [Pg.41]    [Pg.45]    [Pg.337]    [Pg.337]    [Pg.119]    [Pg.545]    [Pg.77]    [Pg.376]    [Pg.407]   