Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Parallel detection

The quantum number constraint leads to the two quite distinct polarization classes of QB spectra AM = 0 beats (polarization of excitation and detection parallel to static field, M = M = M" = M ") and AM = 2 beats (perpendicular polarization, M — M + 2 = M" + 1 = M " + 1). The former type is particularly useful for examining an anticrossing between two perturbing states (provided H12 is small enough). The latter displays both intrastate splittings (useful for measurement of -values and dipole moments) and interstate splittings. [Pg.432]

Another way to speed up HPLC that does not interfere with the existing gradient separation method is by parallel operation of several HPLC columns. The development in this direction started a couple of years ago when fast gradient separation was first combined with mass spectrometry-based detection. Parallel column operation was achieved by a single pumping system and a splitter tee that transferred the gradient flow onto two HPLC columns. The effluent of the two columns was simultaneously sprayed into a modified ion spray interface of a quadrupole mass spec-trometer. From the overlay chromatogram both desired and previously known compounds were identified after their molecular ions were filtered from the total ion current (TIC). In this first system, however, it was difficult to enhance the parallelization, and the detection system created a bottleneck. ... [Pg.308]

No intermediates were detected. Parallel outer-sphere reactions were proposed, in the second of which an association of the two anions [Co(IIl)04Wi2036] and R8 precedes the rate-limiting electron transfer step ... [Pg.75]

Beside this pre-warning feature AE can be used parallel as a NDT technique to detect, locate and roughly grade any active (growing) discontinuity in the structure under test. [Pg.32]

A connnon teclmique used to enliance the signal-to-noise ratio for weak modes is to inject a local oscillator field polarized parallel to the RIKE field at the detector. This local oscillator field is derived from the probe laser and will add coherently to the RIKE field [96]. The relative phase of the local oscillator and the RIKE field is an important parameter in describing the optical heterodyne detected (OHD)-RIKES spectrum. If the local oscillator at the detector is in phase with the probe wave, the heterodyne mtensity is proportional to... [Pg.1208]

If the detection system is an electronic, area detector, the crystal may be mounted with a convenient crystal direction parallel to an axis about which it may be rotated under tlie control of a computer that also records the diffracted intensities. Because tlie orientation of the crystal is known at the time an x-ray photon or neutron is detected at a particular point on the detector, the indices of the crystal planes causing the diffraction are uniquely detemiined. If... [Pg.1379]

Figure Bl.25.12 illustrates the two scattering modes for a hypothetical adsorption system consisting of an atom on a metal [3]. The stretch vibration of the atom perpendicular to the surface is accompanied by a change m dipole moment the bending mode parallel to the surface is not. As explained above, the EELS spectrum of electrons scattered in the specular direction detects only the dipole-active vibration. The more isotropically scattered electrons, however, undergo impact scattering and excite both vibrational modes. Note that the comparison of EELS spectra recorded in specular and off-specular direction yields infomiation about the orientation of an adsorbed molecule. Figure Bl.25.12 illustrates the two scattering modes for a hypothetical adsorption system consisting of an atom on a metal [3]. The stretch vibration of the atom perpendicular to the surface is accompanied by a change m dipole moment the bending mode parallel to the surface is not. As explained above, the EELS spectrum of electrons scattered in the specular direction detects only the dipole-active vibration. The more isotropically scattered electrons, however, undergo impact scattering and excite both vibrational modes. Note that the comparison of EELS spectra recorded in specular and off-specular direction yields infomiation about the orientation of an adsorbed molecule.
Addition of water to solutions of nitric acid in 90% sulphuric acid reduces rates of nitration. Between 90% and 85% sulphuric acid the decrease in rate parallels the accompanying fall in the concentration of nitronium ions. This is good evidence for the operation of the nitronium ion as the nitrating agent, both in solutions more acidic than 90% and in weakly diluted solutions in which nitronium ion is still spectroscopically detectable. [Pg.21]

The KDF filter was first tested in prototype on a coal mine in northern Germany. It was installed in parallel with existing vacuum filters and it produced filter cakes consistendy lower in moisture content by 5 to 7% than the vacuum filters. Two production models have been installed and operated on a coal mine in Belgium. The filter is controlled by a specially developed computer system this consists of two computers, one monitoring the function of the filter and all of the detection devices installed, and the other controlling the filtration process. The system allows optimization of the performance, automatic start-up or shut-down, and can be integrated into the control system of the whole coal washing plant. [Pg.406]

For pipelines in service in chemical plants, it is not usually convenient to place a radiation source inside the pipe and position it to irradiate each welded joint. The radioisotope source container maybe placed on the outer surface of the pipe. The radiation beams then pass through two pipe wall thicknesses to expose films placed diametrically opposite the radiation source, also on the outside of the pipe wall. Other methods, such as magnetic particle inspection of welds in steel pipe, or ultrasonic inspection of welds in pipes of all materials, supplement x-rays in many critical appHcations. The ultrasonic tests can often detect the thin, laminar discontinuities parallel to the pipe surface or the incomplete fusion discontinuities along the weld... [Pg.129]

Real reactors deviate more or less from these ideal behaviors. Deviations may be detected with re.sidence time distributions (RTD) obtained with the aid of tracer tests. In other cases a mechanism may be postulated and its parameters checked against test data. The commonest models are combinations of CSTRs and PFRs in series and/or parallel. Thus, a stirred tank may be assumed completely mixed in the vicinity of the impeller and in plug flow near the outlet. [Pg.2075]

Where three CTs for unrestricted or four CTs for restricted ground fault or combined O/C and G/F protections are employed in the protective circuit, the VA burden of the relay is shared by all the CTs in parallel and a normal VA CT may generally suffice. Such is the case in most of the protective schemes discussed in Sections 21.6 and 15.6.6(1), except for those employing only one CT to detect a ground fault condition, such as for a generator protection with a solidly grounded neutral (Figure 21.12). [Pg.474]


See other pages where Parallel detection is mentioned: [Pg.563]    [Pg.156]    [Pg.115]    [Pg.22]    [Pg.720]    [Pg.420]    [Pg.149]    [Pg.1205]    [Pg.563]    [Pg.156]    [Pg.115]    [Pg.22]    [Pg.720]    [Pg.420]    [Pg.149]    [Pg.1205]    [Pg.166]    [Pg.768]    [Pg.902]    [Pg.981]    [Pg.1297]    [Pg.1433]    [Pg.1573]    [Pg.10]    [Pg.218]    [Pg.181]    [Pg.292]    [Pg.73]    [Pg.198]    [Pg.51]    [Pg.129]    [Pg.170]    [Pg.548]    [Pg.465]    [Pg.393]    [Pg.22]    [Pg.296]    [Pg.1552]    [Pg.230]    [Pg.688]    [Pg.814]    [Pg.832]    [Pg.95]    [Pg.54]    [Pg.203]    [Pg.204]    [Pg.298]   
See also in sourсe #XX -- [ Pg.3 , Pg.4 , Pg.5 , Pg.6 , Pg.7 , Pg.8 , Pg.9 , Pg.10 , Pg.11 , Pg.12 , Pg.13 , Pg.14 , Pg.15 , Pg.16 , Pg.17 , Pg.18 , Pg.19 , Pg.20 ]




SEARCH



Parallel-detection EELS

Trace detection of elements in parallel by emission spectrography survey analysis (see also Chapter

© 2024 chempedia.info