Central to all SPMs (or local probe methods , or local proximal probes as they are sometimes called) is the presence of a tip or sensor, typically of less than 100 mn radius, that is rastered in close proximity to—or in contact with—tire sample s surface. This set-up enables a particular physical property to be measured and imaged over the scaimed area. Crucial to the development of this family of teclmiques were both the ready availability of piezoelements, with which the probe can be rastered with subnanometre precision, and the highly developed computers and stable electronics of the 1980s, without which the operation of SPMs as we know them would not have been possible. [Pg.1676]

From the above-made review of literature, one may infer that the interaction of metastable atoms of rare gases with a surface of semiconductors and dielectrics is studied, but little. The study of the mechanism of transferring energy of electron-excited particles to a solid body during the processes under discussion is urgent. The method of sensor detection of rare gas metastable atoms makes it possible to obtain new information about the heterogeneous de-excitation of metastable atoms inasmuch as it combines high sensitivity with the possibility to conduct measurements under different conditions. [Pg.326]

Conductivity sensors are most commonly used for safety purposes in household appliances. Presence and absence of washing liquor, detergency, and water softener can be easily measured and proper operation ensured [71]. The various applications mainly differ by their design of electrode geometry and methods for electrical measurement. Due to the close relation between ionic conductivity and water hardness, the automatic water softener in an automatic dishwasher can be controlled by a conductivity sensor [72]. To isolate the transmission of the measured value from the process controller, the conductivity sensor could incorporate an opto-electronical coupling [73]. Thus, protective insulation of the electrodes in a washer-dryer could be ensured. [Pg.107]

The hypothesis of a normal distribution is a strong limitation that should be always kept in mind when PCA is used. In electronic nose experiments, samples are usually extracted from more than one class, and it is not always that the totality of measurements results in a normally distributed data set. Nonetheless, PCA is frequently used to analyze electronic nose data. Due to the high correlation normally shown by electronic nose sensors, PCA allows a visual display of electronic nose data in either 2D or 3D plots. Higher order methods were proposed and studied to solve pattern recognition problems in other application fields. It is worth mentioning here the Independent Component Analysis (ICA) that has been applied successfully in image and sound analysis problems [18]. Recently ICA was also applied to process electronic nose data results as a powerful pre-processor of data [19]. [Pg.156]

The fabrication process of vanadium oxide (VO2) has also been studied using RBS/C. Since optieal and electrical properties of VO2 are dramatically changed at 68°C due to phase transition, VO2 is regarded as one of the candidates for thermally activated electronic or optical switching devices for optieal fibers or sensors. To obtain the desired properties, the development of the fabrication process for very thin films, without crystalline defects on various substrates, is required. Single-crystalline VO2 thin films on (0001) plane of a sapphire substrate have been synthesized by a laser ablation method. The quality of VO2 was examined by X-ray diffraction and RBS/C method. The eleetrieal resistanee and the optical transmittance of the VO2 film were measured under inereasing and deereasing temperatures. At a temperature of 68 °C, an abrupt transition of resistanee from metal to... [Pg.843]

Several analytical devices have found application as test sensors or, more generally, as electronic tongues for characterizing foods or food ingredients, being able to provide information related to the human sensorial perception or to other important features. There are some examples of electronic tongues based on optical techniques as well as on mass measurements, but the analytical methods that have been most widely exploited in this field are, without any doubt, the electrochemical ones, as shown in Fig. 2.6. [Pg.66]

A2.1 Factors to Consider When Estimating Water Vapor Pressure A2.2 Dew-Point Method for the Determination of Water Activity A2.3 Measurement of Water Activity Using Isopiestic Method A2.4 Direct Manometric Determination of Vapor Pressure A2.5 Measurement of Water Activity by Electronic Sensors... [Pg.1]

A multilaboratory, multi-instrument study of the use of electronic sensors applied to a cross-section of commodities and reference standards demonstrated that measurements of water activity by the described method (with instruments using immobilized salt solution sensors) can be made with an accuracy and precision within 0.01 water activity unit, provided there are no interactions between the instrument and the commodity under investigation (Stoloff, 1978). Commodity-instrument interactions did exist with a number of products, especially those containing highly volatile compounds. [Pg.68]

The isopiestic and manometric methods (units A2j A2.4) for determination of water activity have the limitation of being dependent on fixed laboratory equipment. The electronic-type sensors have advantages of portability, speed, and simplicity of measurement. The characteristics of a sensor depend upon the manufacturer and each instrument must be calibrated separately. The anodized sensors have advantages of ruggedness, small dimensions, and fast response, as well as freedom from large temperature coefficients and less susceptibility to contamination of the lithium chloride conductivity sensors (Smith, 1971). [Pg.69]

Fig. 1. The accuracy of e-beam lithography is illustrated in the scanning electron micrograph (top). The size of the features formed in the silicon oxide is 0.5 pm and the typical animal cell (a fibroblast) has a diameter of 20 pm. This kind of cell adheres actively to surfaces, forming thin filopodia which here have all attached to the micro-hillocks. Semiconductor technology is capable of manufacturing micro-electrodes, sensors, pores and electronic networks with sizes smaller than that of the cell. The lower illustration summarises the main detection and measuring methods currently in use... Fig. 1. The accuracy of e-beam lithography is illustrated in the scanning electron micrograph (top). The size of the features formed in the silicon oxide is 0.5 pm and the typical animal cell (a fibroblast) has a diameter of 20 pm. This kind of cell adheres actively to surfaces, forming thin filopodia which here have all attached to the micro-hillocks. Semiconductor technology is capable of manufacturing micro-electrodes, sensors, pores and electronic networks with sizes smaller than that of the cell. The lower illustration summarises the main detection and measuring methods currently in use...
Nowadays, the most commonly used DO electrode is the polarographic that employs an electrochemical method, through the reduction of molecular oxygen at the platinum electrode (cathode) generating electrons for the silver oxidation at the silver/silver chloride electrode (anode). In this type of sensor, it is necessary to impose an external voltage and the resulting current is measured and converted into dissolved oxygen concen-... [Pg.263]

Amperometric biosensors based on flavin-containing enzymes have been studied for nearly 30 years. These sensors typically undergo several chemical or electrochemical steps which produce a measurable current that is related to the substrate concentration. In the initial step, the substrate converts the oxidized flavin adenine dinucleotide (FAD) center of the enzyme into its reduced form (FADH2). Because these redox centers are essentially electrically insulated within the enzyme molecule, direct electron transfer to the surface of a conventional electrode does not occur to a substantial degree. The classical" methods (1-4) of indirectly measuring the amount of reduced enzyme, and hence the amount of substrate present, rely on the natural enzymatic reaction ... [Pg.117]

There are also new methods suggested recently, but they are not yet commonly employed.5 One of them involves ion-selective field effect transistor as a sensor, which requires smaller measurement area compared to the glass electrode.10 Other possible methods are electron spin resonance imaging and confocal microscopy.5 11 12 They require treatment of the skin with an indicator substance, which penetrates into the epidermis and allows the pH to be detected in several layers simultaneously.12... [Pg.162]

Microdielectrometry was introduced as a research method in 1981 14 and became commercially available in 1983 20). The microdielectrometry instrumentation combines the pair of field-effect transistors on the sensor chip (see Sect. 2.2.3) with external electronics to measure the transfer function H(co) of Eq. (2-18). Because the transistors on the sensor chip function as the input amplifier to the meter, cable admittance and shielding problems are greatly reduced. In addition, the use of a charge measurement rather than the admittance measurement allows the measurements to be made at arbitrarily low frequencies. As a matter of practice, reaction rates in cure studies limits the lowest useful frequency to about 0.1 Hz however, pre-cure or post-cure studies can be made to as low as 0.005 Hz. Finally, the differential connection used for the two transistors provides first-order cancellation of the effects of temperature and pressure on the transistor operation. The devices can be used for cure measurements to 300 °C, and at pressures to 200 psi. [Pg.14]


See other pages where Sensor measurement, electronic methods is mentioned: [Pg.1301]    [Pg.4]    [Pg.294]    [Pg.270]    [Pg.301]    [Pg.6]    [Pg.66]    [Pg.31]    [Pg.26]    [Pg.136]    [Pg.18]    [Pg.387]    [Pg.379]    [Pg.296]    [Pg.388]    [Pg.417]    [Pg.109]    [Pg.379]    [Pg.205]    [Pg.201]    [Pg.251]    [Pg.205]    [Pg.213]    [Pg.64]    [Pg.136]    [Pg.879]    [Pg.314]    [Pg.240]    [Pg.58]    [Pg.180]    [Pg.304]    [Pg.767]    [Pg.208]    [Pg.310]    [Pg.302]    [Pg.191]   