Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Selectivity method development

Abstract The 8-lactone moiety is a common structural framework found in many natural products that exhibit interesting biological properties. This review details a collection of various selected methods developed for the synthesis of saturated 8-lactones. Synthesis of unsaturated 8-lactones and manipulation thereof to sam-rated 8-lactones are not covered in this review. [Pg.97]

Stage in the development of a practical and selective method involved a detailed investigation of the many experimental variables and a in depth study of the nature of the species responsible for the observed selectivity. [Pg.127]

Since most often the selective formation of just one stereoisomer is desired, it is of great importance to develop highly selective methods. For example the second step, the aldol reaction, can be carried out in the presence of a chiral auxiliary—e.g. a chiral base—to yield a product with high enantiomeric excess. This has been demonstrated for example for the reaction of 2-methylcyclopenta-1,3-dione with methyl vinyl ketone in the presence of a chiral amine or a-amino acid. By using either enantiomer of the amino acid proline—i.e. (S)-(-)-proline or (/ )-(+)-proline—as chiral auxiliary, either enantiomer of the annulation product 7a-methyl-5,6,7,7a-tetrahydroindan-l,5-dione could be obtained with high enantiomeric excess. a-Substituted ketones, e.g. 2-methylcyclohexanone 9, usually add with the higher substituted a-carbon to the Michael acceptor ... [Pg.242]

High performance liquid chromatography (HPLC) is an excellent technique for sample preseparation prior to GC injection since the separation efficiency is high, analysis time is short, and method development is easy. An LC-GC system could be fully automated and the selectivity characteristics of both the mobile and stationary... [Pg.304]

Battersby and coworkers have developed selective methods for total synthesis of chlorins on a model system, as shown in Scheme 10.15, in which the Michael addition of 5-f3-nittoethyl pyrrole to enone and reductive cyclizadon are used as key steps. "... [Pg.348]

In the new polar organic mode, the ratio of acid/base in the mobile phase affects the selectivity and the concentration of acid and base controls the retention. It is suggested to start the method development with a medium concentration (0.1 %) for both acid and base. If retention is too long or too short, the concentration can be increased to 1 % or reduced to 0.01 %. If no selectivity is observed in this mode, reversed phase is recommended as the next step in the protocols. [Pg.38]

When analytes lack the selectivity in the new polar organic mode or reversed-phase mode, typical normal phase (hexane with ethanol or isopropanol) can also be tested. Normally, 20 % ethanol will give a reasonable retention time for most analytes on vancomycin and teicoplanin, while 40 % ethanol is more appropriate for ristocetin A CSP. The hexane/alcohol composition is favored on many occasions (preparative scale, for example) and offers better selectivity for some less polar compounds. Those compounds with a carbonyl group in the a or (3 position to the chiral center have an excellent chance to be resolved in this mode. The simplified method development protocols are illustrated in Fig. 2-6. The optimization will be discussed in detail later in this chapter. [Pg.38]

Each glycopeptide CSP has unique selectivity as well as complementary characteristics, and a considerable number of racemates have been resolved on all three of them. Interestingly, most of the resolved enantiomers have the same retention order on these macrocyclic CSPs. When they are mixed or coupled with each other, the selectivity on one CSP will not be canceled by another. Even if some compounds may not have the same retention order, the complementary effects will result in an identifiable selectivity. Therefore, the coupled chiral columns can be used as a screening tool and save chromatographers substantial time in method development. [Pg.40]

The epoxidation method developed by Noyori was subsequently applied to the direct formation of dicarboxylic acids from olefins [55], Cyclohexene was oxidized to adipic acid in 93% yield with the tungstate/ammonium bisulfate system and 4 equivalents of hydrogen peroxide. The selectivity problem associated with the Noyori method was circumvented to a certain degree by the improvements introduced by Jacobs and coworkers [56]. Additional amounts of (aminomethyl)phos-phonic acid and Na2W04 were introduced into the standard catalytic mixture, and the pH of the reaction media was adjusted to 4.2-5 with aqueous NaOH. These changes allowed for the formation of epoxides from ot-pinene, 1 -phenyl- 1-cyclohex-ene, and indene, with high levels of conversion and good selectivity (Scheme 6.3). [Pg.198]

This symposium addressed several important issues in bromine chemistry. A major part has been devoted to stereochemistry and mechanism of electrophilic bromination of olefins. Other topics included new selective methods of bromination and oxybromination, brominations in presence of solid supports and catalysts, organobromine compounds as synthons, recent developments in brominated fire retardants and toxicological and environmental aspects of brominated compounds. [Pg.2]

Bromo compounds are useful intermediates for the synthesis of a range of more complicated organic compounds via direct substitution or by prior conversion into organometallic reagents. They therefore hold a key position in the synthesis of fine chemicals. This position demands that more selective methods for the synthesis of bromo compounds also be developed. In this report we have illustrated the development of selected syntheses of bromoaromatic compounds and demonstrated new ways in which they can be applied in synthetic procedures. [Pg.63]

Negative-ion Cl tends to be a very selective method of ionization which generates reduced levels of background, thus allowing sensitive analyses to be developed for appropriate analytes. [Pg.56]

The final choice will have to be made during method development and/or analysis of the real samples, e.g. one of the ions selected may provide superb data from standard solutions but show a high matrix background on all or, perversely, on only a small number of samples, which will preclude its/their use. [Pg.72]

The issue of selectivity is one that is often difficult to address. Initial method development is invariably carried out by using standards made up with pure solvents, i.e. free from any matrix effects. It is often only when real samples are analysed that the true extent of interference becomes apparent and the value of the method can be properly assessed. An added complication is that interferences , by their very nature, are not constant and a number of samples may have a combination of interferences that defy analysis by a method that is otherwise successful on a routine basis (another example of Murphy s law ). [Pg.269]

The fact that APCl and electrospray are soft ionization techniques is often advantageous because the molecular ion alone, in conjunction with HPLC separation, often provides adequate selectivity and sensitivity to allow an analytical method to be developed. Again, method development is important, particularly when more than one analyte is to be determined, when the effect of experimental parameters, such as pH, flow rate, etc., is not likely to be the same for each. Electrospray, in particular, is susceptible to matrix effects and the method of standard additions is often required to provide adequate accuracy and precision. [Pg.290]

Matrix SRM s, Matrix SRM s can be used for a variety of functions. Taylor (71) reviewed the uses of matrix standards, which Include (a) method development and evaluation, (b) establishment of measurement traceability, and (c) assurance of measurement compatibility. During certification of these matrix SRM s, the selectivity of fluorescence... [Pg.117]

Compound selection methods usually involve selecting a relatively small set of a few tens or hundreds of compounds from a large database that could consist of hundreds of thousands or even millions of compounds. Identifying the n most dissimilar compounds in a database containing N compounds, when typically n N, is computationally infeasible because it requires consideration of all possible n-member subsets of the database, and therefore approximate methods have been developed as described below. [Pg.199]

The variable selection methods have been also adopted for region selection in the area of 3D QSAR. For example, GOLPE [31] was developed with chemometric principles and q2-GRS [32] was developed based on independent CoMFA analyses of small areas of near-molecular space to address the issue of optimal region selection in CoMFA analysis. Both of these methods have been shown to improve the QSAR models compared to original CoMFA technique. [Pg.313]

The simplest and cheapest procedure to obtain standards is based on selective extraction followed by crystallization. A method developed to obtain lycopene from tomato residue using factorial experimental design consisted of a preliminary water removal with ethanol, followed by extraction with EtOAc and two successive crys-talhzation processes using dichloromethane and ethanol (1 4), producing lycopene crystals with 98% purity, measured by HPLC-PDA. Using this approach, bixin was extracted with EtOAc from annatto seeds that were previously washed with... [Pg.471]

A plefhora of methods developed for the determination of triazine compounds in water, soil, crops, biological fluids, etc., have been reported in the literature, and several excellent reviews are available for the interested reader. " More method papers are published on the determination of triazines in water than for all other sample matrices combined (water > soil > crop). The majority of the water method reports relate to the determination of parent triazine compounds plus compounds from one or more other chemical classes of pesticides (e.g., phenoxy acids, carbamates, pheny-lureas, acetanilides, acetamides, organophosphorus compounds, etc.) for generalized multi-residue screening or monitoring purposes. Addressed in other more selective... [Pg.415]


See other pages where Selectivity method development is mentioned: [Pg.264]    [Pg.222]    [Pg.122]    [Pg.163]    [Pg.180]    [Pg.348]    [Pg.264]    [Pg.222]    [Pg.122]    [Pg.163]    [Pg.180]    [Pg.348]    [Pg.83]    [Pg.67]    [Pg.363]    [Pg.254]    [Pg.411]    [Pg.151]    [Pg.297]    [Pg.299]    [Pg.167]    [Pg.167]    [Pg.311]    [Pg.4]    [Pg.199]    [Pg.368]    [Pg.457]    [Pg.127]    [Pg.310]    [Pg.4]    [Pg.301]    [Pg.444]   
See also in sourсe #XX -- [ Pg.499 ]




SEARCH



Chemisorption selective, method development

Chromatographic mode selection HPLC method development

Developer selectivity

Factor selection method development

HPLC method development column selection

HPLC method development mobile phase selection

HPLC method development solvent selection

Level selection, method development

Level selection, method development case studies

Method development

Method development solvent selectivity

Method selection

Method selectivity

Reverse phase method development selectivity

SELECT method

Selective development

Selective methods

Selectivity development

© 2024 chempedia.info