Rotary pumps installation

In the case of operations ranging between 760 and 10 3 torr, the two-stage rotary pump is adequate. Ultimate vacuum, using the diffusion pump installation, is better than 10-6 torr. [Pg.106]

The exhaust from a rotary pump, especially if it is being run in the ballast mode, i.e. pumping a fair quantity of air or other gas, is an aerosol of oil in the gases from the line. A variety of filters is now available commercially for cleaning exhaust gas, but a good additional safety precaution is a wide tube fitted to the outlet so that the gas stream can be vented to the nearest fume-cupboard or window. The pumping efficiency of a rotary pump drops off rapidly below ca. 10 Torr even under optimum conditions, and such pumps are therefore usually installed as a back-up to a more efficient high vacuum pump, such as a diffusion or a turbomolecular pump. [Pg.32]

The main analytical instrumentation in the vehicle is a benchtop GC/MS by Hewlett Packard, HP 5890 GC/5970 MSB (mass selective detector). A basic configuration for analyzing liquid samples includes a heated injection port and a capillary fused-silica column interfaced directly to the MS via a heated transfer line. The MS is a quadrupole design operated under vacuum provided by a diffusion pump and backed by a mechanical rotary pump. System operation and data analysis are performed by a Pentium-level personal computer loaded with proprietary software and a NBS spectral library to aid with identification of unknowns. Depending on the mission, a simpler installation may consist of a GC equipped with an appropriate detector such as the electron capture detector (ECD). [Pg.369]

Uquid viscosity is higher than spedfted for pump. Options Reduce fluid viscosity by heating or diluting. Install a larger impeller if possible. Replace centrifugal with rotary pump. [Pg.124]

Two pairs of turbo molecular pumps and rotary pumps were Installed. The pressures of regions (I), (II) and (III) are 10 Torr, lO" Torr and 10 Torr, respectively. Typical plasma parameters are as follows the electron density e = 510" cm, the electron temperature 1 = 2 eV. [Pg.856]

This type of seal has the rotary component and face mounted outside the seal chamber. The springs and drive elements are outside the pumped liquid. This reduces the problems associated with corrosion and the accumulation of pumped product clogging the springs. This seal is popular in the food processing industry. The pumped liquid arrives to the inside diameter of the faces and seals toward the outside diameter. The environment outside the pump approaches the OD of the face union. Pressures are limited to about 35 psig. Sometimes this. seal can be mounted either inside or outside the pump. This seal is easy to install, adjust, and maintain. It permits easy access and cleaning of the pump internal parts, often required in the food processing industry. [Pg.186]

A strainer should be used in the pump suction line temporarily for a centrifugal pump and permanently for the rotary positive displacement pump. For the permanent installations, a Y-type strainer with an austenitic stainless strainer basket should be used. The cross-sectional... [Pg.311]

On small installations an elevated tank above the furnace would be used (refer to Figure 37). The savings from eliminating the pumps, valving, and slurry lines are offset by the additional cost of a structure to support the tank and a rotary feed valve. The tank is fitted with a screened overflow. A dewatering screw conveyor is used for feeding the furnace. [Pg.312]

Installation requirements for rotary positive-displacement compressors are similar to any rotating machine. Review the installation requirements for centrifugal pumps and compressors for foundation, pressure-relief, and other requirements. As with centrifugal compressors, rotary positive-displacement compressors must be fitted with pressure-relief devices to limit the discharge or inter-stage pressures to a safe maximum for the equipment served. [Pg.561]

The motors supplied with the rotary vane and rotary plunger pumps deliver enough power at ambient temperatures of 12 °C and when using our special oils to cover the maximum power requirement (at about 400 mbar). Within the actual operating range of the pump, the drive system of the warmed up pump needs to supply only about one third of the Installed motor power (see Fig. 2.11). [Pg.24]

Fig. 6.4. Cross-section of a metal diffusion pump. The upper stage in this pump has a wide annular opening (A) which provides a good ultimate vacuum. The lower stage has a small annular opening (A ) so the pump will operate against a high fore pressure. (B) High-vacuum connection to the low-temperature trap and vacuum line. (C) Connection to rotary oil-sealed pump. This pump is cooled by means of water tubes (D). Air-cooled versions have fins in place of these tubes and a fan is installed to blow air over these fins. (E) Electrically heated oil reservoir. Fig. 6.4. Cross-section of a metal diffusion pump. The upper stage in this pump has a wide annular opening (A) which provides a good ultimate vacuum. The lower stage has a small annular opening (A ) so the pump will operate against a high fore pressure. (B) High-vacuum connection to the low-temperature trap and vacuum line. (C) Connection to rotary oil-sealed pump. This pump is cooled by means of water tubes (D). Air-cooled versions have fins in place of these tubes and a fan is installed to blow air over these fins. (E) Electrically heated oil reservoir.
Drilling. Common drill rigs available for monitor-well installation include cable tool, air rotary, mud rotary, reverse rotary, and hollow-stem auger. The cable tool rig repeatedly lifts and drops a drill bit, drill stem, drilling jars, and rope socket. The drill bit crushes hard rock or loosens unconsolidated material and mixes the loosened particles with water to form a slurry or sludge. The sludge is removed at intervals by a sand pump or a bailer. [Pg.166]

Higher pressures are required for pressure-assisted separations in packed columns used for capillary electrochromatography [235,376,464-466]. These columns require a high-pressure pump to provide the supplementary mobile phase flow. Conventional rotary injection valves and autosamplers can be used for sample introduction with this arrangement if a special inlet tee housing the electrode and split line with a restrictor is installed [422]. Microcolumn pumps are also useful for conditioning columns before initial use in capillary electrochromatography (section 8.4.2). There are no com-... [Pg.694]

Vacuum systems with rotary vane vacuum pumps may be used where the process requires vacuums < 50 mbar or if liquid ring vacuum pumps cannot be used in the installation. These vacuum systems are designed to separate out as much of the process vapours and particles as possible on the intake side or to condense the process vapours into the atmosphere as moist air. Rotary vane vacuum pumps may be operated as recirculahng lubrication or blow-by vacuum pumps. The vacuum pump is built with a rotor turning eccentrically in a cylinder. The rotor has axial slots and rotating vanes are pressed against the cylinder by centrifugal force in these slots (Fig. 3). [Pg.312]

Vacuum systems with rotary vane vacuum pumps have the advantage that vacuums of < 1 mbar are theoretically possible, regardless of the ambient and water temperatures in the installation. The effect of the process on the possible operating pressure should be checked. [Pg.314]

Rotary disk filter, vacuum, c/s, heavy duty mineral processing with filter and agitator but exduding vacuum system and vacuum recdver, filtrate pump, moisture trap and scrubber condenser. FOB cost = 265 000 for a total disk, number X 2nD, area = 100 m with n = 0.38 for the range 8-100 and n = 0.55 for the range 100-250. TM = 4 if installed on floor 4.5 if installed devated. [Pg.413]

Purchase of a vacuum vapor degreaser is likely to include a rotary vane vacuum pump among the installed components. Commercial rotary vane vacuum pumps also may have more than two rotating vanes as are shown in Figures 2.5a and b. Any even number ofvanes is possible. Figure 2. shows an image of a rotor with six vanes. [Pg.71]


See other pages where Rotary pumps installation is mentioned: [Pg.255]    [Pg.24]    [Pg.38]    [Pg.140]    [Pg.27]    [Pg.117]    [Pg.117]    [Pg.321]    [Pg.1060]    [Pg.100]    [Pg.1063]    [Pg.545]    [Pg.240]    [Pg.212]    [Pg.46]    [Pg.62]    [Pg.117]    [Pg.121]    [Pg.136]    [Pg.1248]    [Pg.2084]    [Pg.182]    [Pg.286]    [Pg.72]    [Pg.31]    [Pg.65]   
See also in sourсe #XX -- [ Pg.277 , Pg.278 ]