Resolution, column

Principles and Characteristics A sample can contain a great number of compounds, but analysts are usually interested only in the qualitative presence (and the quantitative amount) of a small number of the total compounds. Selectivity is an important parameter in analytical separations. The total analytical process clearly benefits from selectivity enhancement arising from appropriate sample preparation strategies. Selective separation of groups or compound classes can simplify a mixture of analytes before analysis, which in turn enhances analytical precision and sensitivity. Selective fractionation, in some cases, allows easier resolution of the compounds of interest, so analysts can avoid the extreme conditions of high-resolution columns. [Pg.138]

Direct Packed, SCOT, large bore WCOT 200 ng per component Direct quantitation Ease of operation High sample capacity Flash vaporisation Decreased resolution (column requirements)... [Pg.189]

Product manufacture entails viral vector propagation in a suitable animal packing cell line (known as HEK 293). After cell recovery and lysis, the crude product is clarified by filtration and concentrated by ultrafiltration. The product is then treated with a nuclease preparation in order to degrade contaminant DNA and further downstream processing entails multi-step high-resolution column chromatography (see also Figure 14.7). [Pg.442]

Zweigenbaum and co-workers [11] used high flow rates and an isocratic system using a Mac-Mod Rapid Resolution column (15 mm x 2.1 mm, 3 pm) to perform the fast separation of six benzodiazepines isolated from human urine using a 96-well liquid-liquid extraction (LLE). [Pg.51]

Conventional chromatography on a silica gel column coated with optically active TAPA results in partial resolution of some helicenes, but the technique is slow and inefficient 81,40). For chromatographical resolution columns of optically active... [Pg.86]

The overall conversion of 4 to API was thus progressively improved from 25.8% for the classical route to 33.4% for the enzymatic route (no recychng) and 42% for the enzymatic route with recychng. Pregabahn is a large-volume product for Pfizer. Based upon projected sales and the figures in Table 8.3 (final column), it is expected that between 2007 and 2020 the environmental savings (versus those in the classical-resolution column) wiU be ... [Pg.172]

A typical column setup is shown in Figure 3.6. The heart of the system is, of course, the column of adsorbent. In general, the longer the column, the better the resolution of components. However, a compromise must be made because flow rate decreases with increasing column length. The actual size of a column depends on the nature of the adsorbing material and the amount of chemical sample to be separated. For preparative purposes, column heights of 20 to 50 cm are usually sufficient to achieve acceptable resolution. Column inside diameters may vary from 0.5 to 5 cm. [Pg.71]

Multidimensional LC-LC, using two high-resolution columns with orthogonal separation mechanisms, has only a few applications in environmental analysis. The limitations that such a multidimensional system has with regard to selectivity must... [Pg.341]

Although the oldest type of columns, these are presently the most popular nonpartition columns because they can separate large biological molecules such as proteins and nucleic acids. By means of controlled pore sizes, they separate compounds by their molecular size and shape. The resolution achieved by a size resolution column is not nearly as great as that shown by ion exchange or by partition. You will need a 100% difference in molecular weights to achieve a clean separation. Partition can separate on the basis of a proton up or down out of 13 protons on a compound. [Pg.98]

Nanoflow HPLC—HPLC system with accurately controlled reciprocating and syringe pumps designed to use capillary and small diameter, high-resolution columns as front ends for electrospray and nanospray mass spectrometer interfaces. [Pg.217]

High-speed columns yield 5000-10,000 plates per meter, whereas most high-resolution columns give 3000-5000 plates per meter. Most applications of capillary columns are with column lengths of 10-50 m and are somewhat dependent on the complexity of the sample and the number of components of interest. A general rule is that samples with 20-50 components are best handled on columns of 20-30 m, whereas samples of 50 or more components will require 30-50 m of column. [Pg.305]

Fig. 1.23. Top the window diagram (the dependence of the resolution on the concentration of 2-propanol in ri-heptane as the mobile phase) for a mixture of eight phenylurea herbicides on a Separon SGX, 7.5 pm. silica gel column (150 x 3.3 mm i.d.). Bottom the separation with optimised concentration 1953 2-propanol in the mobile phase for maximum resolution. Column plaie number N = 5000. T = 40°C. flow rate 1 ml/min. Sample compounds neburon (/). chlorobromuron (2). 3-chloro-4-methylphenylurea (7). desphenuron (4). isoproturon (5). diuron (6). metoxuron (7). dcschlorometoxuron (S). Fig. 1.23. Top the window diagram (the dependence of the resolution on the concentration of 2-propanol in ri-heptane as the mobile phase) for a mixture of eight phenylurea herbicides on a Separon SGX, 7.5 pm. silica gel column (150 x 3.3 mm i.d.). Bottom the separation with optimised concentration 1953 2-propanol in the mobile phase for maximum resolution. Column plaie number N = 5000. T = 40°C. flow rate 1 ml/min. Sample compounds neburon (/). chlorobromuron (2). 3-chloro-4-methylphenylurea (7). desphenuron (4). isoproturon (5). diuron (6). metoxuron (7). dcschlorometoxuron (S).
J2. Jolley, R. L., Warren, K. S., Scott, C. D., Jainchill, J. L., and Freeman, M. L., Carbohydrates in normal urine and bbod serum as determined by high resolution column chromatography. Amer. J. Clin. Pathol. 53, 793-802 (1970). [Pg.40]

Various types of column can be combined. Sequential analysis with liquid chromatography can first pass the sample through a gel to separate constituents according to their molecular size, followed by some form of affinity chromatography using partition or adsorption. A two-column GLC system for steroid analysis has been described (H22), in which the sample is first introduced to a high-capacity low-resolution column for a preliminary separation. After a suitable time, the flow of gas is re-... [Pg.349]

The method of stationary-phase preparation has a major effect on the resolution, column stability, retention time, reproducibility, and peak shape. When preparing Cjg or Cg, for example, it is important that the residual silanol groups are capped to prevent peak tailmg. The extent of capping must be consistently maintained between different batches of the stationary phase for reproducible results. [Pg.923]

A few years later, by using the same experimental procedures, the same scientists prepared cyclic polybutadienes170 (Scheme 82). THF was the polymerization solvent, which results in a 60% 1,2-content. From the g values was concluded that some of the cyclic polybutadienes (PBd) were contamined by their linear precursors. A high-resolution column set was used in order to separate the linear from the cyclic polymer. In this work the characterization analysis was the most comprehensive presented so far. Recently, these cyclic PSs were analyzed by high-pressure liquid chromatography under critical conditions, which is a method that can separate linear and cyclic macromolecules according to their archi-... [Pg.599]

The most widely used silica open tubular columns have inside diameters of 0.32 and 0.25 mm. Higher resolution columns are also sold with diameters of 0.20 and... [Pg.959]

In many cases, despite some loss of resolution, column overloading is an economic and viable method for compound purification. In analytical LC, the ideal peak shape is a Gaussian curve. If under analytical conditions a higher amount of sample is injected, peak height and area change, but not peak shape or the retention factor. However, if more than the recommended amount of sample is injected onto the column, the adsorption isotherm becomes nonlinear. As a direct consequence, resolution decreases, and peak retention... [Pg.19]


See other pages where Resolution, column is mentioned: [Pg.76]    [Pg.66]    [Pg.172]    [Pg.151]    [Pg.163]    [Pg.1110]    [Pg.22]    [Pg.305]    [Pg.139]    [Pg.85]    [Pg.114]    [Pg.272]    [Pg.304]    [Pg.89]    [Pg.273]    [Pg.23]    [Pg.2850]    [Pg.235]    [Pg.204]    [Pg.669]    [Pg.1444]    [Pg.340]    [Pg.179]    [Pg.180]    [Pg.181]    [Pg.521]    [Pg.88]    [Pg.137]   
See also in sourсe #XX -- [ Pg.183 ]




SEARCH



Capillary columns, high resolution capability

Chromatography, column, in resolution A- chloride

Chromatography, column, in resolution tris with

Column Dimensions and Film Thickness with Parameters in the Fundamental Resolution Equation

Column diameter resolution enhancement

Column efficiency, effect chromatographic resolution

Column length resolution enhancement

Column resolution, HPLC

Column resolution, chromatographic

Column switching, resolution

Diameter, column, resolution

Fused silica column resolution enhancement

High resolution separation column

High resolution separation column Chromatography Mass Spectroscopy in Polymer Analysis

High resolution separation column Initiation

High resolution separation column Latex

High resolution separation column Liquid chromatography

High resolution separation column Mass detection

High resolution separation column Mass spectroscopy

High resolution separation column Molecular weight

High resolution separation column Oligomers

High resolution separation column Polyethylene

High resolution separation column Polysiloxanes

High resolution separation column Polystyrene

High resolution separation column Precursors

High resolution separation column Pyrolysis

High resolution separation column Ultraviolet detection

Length, column, resolution

Resolution capillary columns

Resolution column chromatography

Resolution column chromatography definition

Resolution column efficiency

Resolution of columns

Resolution packed columns

Resolution series connected columns

Using Column Efficiency to Optimize Resolution

Using Column Selectivity to Optimize Resolution