Analytical enhancement

The most common enhancement factor is the analytical enhancement factor (AEF), which is defined as follows ... [Pg.3168]

Shi L., Pottier R, Skorobogatiy M. and Peter Y.A. (2009), Tunable structures comprising two photonic crystal slabs - optical study in view of multi-analyte enhanced detection. Optics Express, 17 pp. 10623-10632. [Pg.473]

Trapping onto solid- For analyte enhancement and removal... [Pg.149]

T. L. Clerc, in Computer-Enhanced Analytical Spectroscopy, H. L. C. Meuzelaar, T.L. Isenhour (Eds.), Plenum Press, New York, 1987, pp. 145-162. Automated spectra interpretation and library search systems. [Pg.537]

J. Gasteiger, W. Hanebeck, K.-P. Schultz, S. Bauerschmidt, R. Hollering, Automatic analysis and simulation of mass spectra, in Computer-Enhanced Analytical Spectroscopy, Vol. 4,... [Pg.541]

Molecular fluorescence and, to a lesser extent, phosphorescence have been used for the direct or indirect quantitative analysis of analytes in a variety of matrices. A direct quantitative analysis is feasible when the analyte s quantum yield for fluorescence or phosphorescence is favorable. When the analyte is not fluorescent or phosphorescent or when the quantum yield for fluorescence or phosphorescence is unfavorable, an indirect analysis may be feasible. One approach to an indirect analysis is to react the analyte with a reagent, forming a product with fluorescent properties. Another approach is to measure a decrease in fluorescence when the analyte is added to a solution containing a fluorescent molecule. A decrease in fluorescence is observed when the reaction between the analyte and the fluorescent species enhances radiationless deactivation, or produces a nonfluorescent product. The application of fluorescence and phosphorescence to inorganic and organic analytes is considered in this section. [Pg.429]

In adsorptive stripping voltammetry the deposition step occurs without electrolysis. Instead, the analyte adsorbs to the electrode s surface. During deposition the electrode is maintained at a potential that enhances adsorption. For example, adsorption of a neutral molecule on a Hg drop is enhanced if the electrode is held at -0.4 V versus the SCE, a potential at which the surface charge of mercury is approximately zero. When deposition is complete the potential is scanned in an anodic or cathodic direction depending on whether we wish to oxidize or reduce the analyte. Examples of compounds that have been analyzed by absorptive stripping voltammetry also are listed in Table 11.11. [Pg.519]

Noncatalytic Reactions Chemical kinetic methods are not as common for the quantitative analysis of analytes in noncatalytic reactions. Because they lack the enhancement of reaction rate obtained when using a catalyst, noncatalytic methods generally are not used for the determination of analytes at low concentrations. Noncatalytic methods for analyzing inorganic analytes are usually based on a com-plexation reaction. One example was outlined in Example 13.4, in which the concentration of aluminum in serum was determined by the initial rate of formation of its complex with 2-hydroxy-1-naphthaldehyde p-methoxybenzoyl-hydrazone. ° The greatest number of noncatalytic methods, however, are for the quantitative analysis of organic analytes. For example, the insecticide methyl parathion has been determined by measuring its rate of hydrolysis in alkaline solutions. [Pg.638]

Thus, either the emitted light or the ions formed can be used to examine samples. For example, the mass spectrometric ionization technique of atmospheric-pressure chemical ionization (APCI) utilizes a corona discharge to enhance the number of ions formed. Carbon arc discharges have been used to generate ions of otherwise analytically intractable inorganic substances, with the ions being examined by mass spectrometry. [Pg.388]

The defects generated in ion—soHd interactions influence the kinetic processes that occur both inside and outside the cascade volume. At times long after the cascade lifetime (t > 10 s), the remaining vacancy—interstitial pairs can contribute to atomic diffusion processes. This process, commonly called radiation enhanced diffusion (RED), can be described by rate equations and an analytical approach (27). Within the cascade itself, under conditions of high defect densities, local energy depositions exceed 1 eV/atom and local kinetic processes can be described on the basis of ahquid-like diffusion formalism (28,29). [Pg.395]

Another significant benefit of a LIMS is the improvement of the overall quaUty of the laboratory. In the case of a laboratory, quaUty is defined as satisfying customer needs in the areas of accuracy, reUabiUty, clarity, and timeliness of analytical information. LIMS can enhance quaUty in a number of ways, eg, in checking conformance to requirements, in organizing and prioritizing work to ensure timeliness, in measuring laboratory performance in areas of technical quaUty and efficiency so as to provide continuous improvement, and in helping the laboratory to communicate clearly, completely, and consistendy (16). [Pg.519]

Luminol-based chemiluminescence methods have also been employed for detection of analytes in flowing stream analytical techniques such capillary electrophoresis (282), flow injection analyses, and hplc (267). AppHcations of the enhanced luminol methodology to replace radioassay methods have been developed for a number of immunological labeling techniques (121,283). [Pg.275]

Polymers and Coatings Advances ia polymer chemistry have resulted ia many successful medical devices, including diagnostic assays (26). Polymers (qv), which can be manufactured ia a wide range of compositions, ate used to enhance speed, sensitivity, and versatiUty of both biosensors and dry chemistry systems to measure vital analytes. Their properties can be regulated by composition variations and modifications. Furthermore, polymers can be configured iato simple to complex shapes. [Pg.42]

Only slightly less accurate ( 0.3—0.5%) and more versatile in scale are other titration techniques. Plutonium maybe oxidized in aqueous solution to PuO " 2 using AgO, and then reduced to Pu" " by a known excess of Fe", which is back-titrated with Ce" ". Pu" " may be titrated complexometricaHy with EDTA and a colorimetric indicator such as Arsenazo(I), even in the presence of a large excess of UO " 2- Solution spectrophotometry (Figs. 4 and 5) can be utilized if the plutonium oxidation state is known or controlled. The spectrophotometric method is very sensitive if a colored complex such as Arsenazo(III) is used. Analytically usehil absorption maxima and molar absorption coefficients ( s) are given in Table 10. Laser photoacoustic spectroscopy has been developed for both elemental analysis and speciation (oxidation state) at concentrations of lO " — 10 M (118). Chemical extraction can also be used to enhance this technique. [Pg.200]

Ammonium acetate has limited commercial uses. It serves as an analytical reagent, and in the production of foam mbber and vinyl plastics it is also used as a diaphoretic and diuretic in pharmaceutical appHcations. The salt has some importance as a mordant in textile dyeing. In a hot dye bath, gradual volatilization of ammonia from the ammonium acetate causes the dye solution to become progressively more acidic. This increase in acidity enhances the color and permanence of the dyeing process. [Pg.362]

As femtomolar detection of analytes become more routine, the goal is to achieve attomolar (10 molar) analyte detection, corresponding to the detection of thousands of molecules. Detection sensitivity is enhanced if the noise ia the analytical system can be reduced. System noise consists of two types, extrinsic and intrinsic. Intrinsic aoise, which represents a fundamental limitation linked to the probabiHty of finding the analyte species within the excitation and observation regions of the iastmment, cannot be eliminated. However, extrinsic aoise, which stems from light scatteriag and/or transient electronic sources, can be alleviated. [Pg.395]

The development of fiber optics technology, user-friendly displays, and enhanced data presentation capabihties have made on-line analysis acceptable within the plant manufactuting environment. However, it is apparent that a barrier stiU exists to some extent within many organizations between the process control engineers, the plant operations department, and the analytical function, and proper sampling is stiU the key to successful process analytical chemistry. The ultimate goal is not to handle the sample at ah. [Pg.397]

The main advantages of the ms/ms systems are related to the sensitivity and selectivity they provide. Two mass analyzers in tandem significantly enhance selectivity. Thus samples in very complex matrices can be characterized quickly with Htde or no sample clean-up. Direct introduction of samples such as coca leaves or urine into an ms or even a gc/lc/ms system requires a clean-up step that is not needed in tandem mass spectrometry (28,29). Adding the sensitivity of the electron multiplier to this type of selectivity makes ms/ms a powerhil analytical tool, indeed. It should be noted that introduction of very complex materials increases the frequency of ion source cleaning compared to single-stage instmments where sample clean-up is done first. [Pg.405]


See other pages where Analytical enhancement is mentioned: [Pg.309]    [Pg.432]    [Pg.327]    [Pg.342]    [Pg.818]    [Pg.3167]    [Pg.719]    [Pg.984]    [Pg.17]    [Pg.149]    [Pg.232]    [Pg.309]    [Pg.432]    [Pg.327]    [Pg.342]    [Pg.818]    [Pg.3167]    [Pg.719]    [Pg.984]    [Pg.17]    [Pg.149]    [Pg.232]    [Pg.540]    [Pg.540]    [Pg.573]    [Pg.8]    [Pg.145]    [Pg.63]    [Pg.65]    [Pg.66]    [Pg.66]    [Pg.67]    [Pg.69]    [Pg.71]    [Pg.201]    [Pg.205]    [Pg.275]    [Pg.260]    [Pg.446]    [Pg.395]    [Pg.395]    [Pg.402]    [Pg.403]    [Pg.70]   
See also in sourсe #XX -- [ Pg.327 , Pg.342 ]