High resolution separation column Molecular weight

Lor a particular analytical separation, each biosolute will have an optimal k] value for maximum resolution with a designated column, flow rate, and mobile phase composition. Similar criteria apply in preparative (overload) chromatography with multicomponent mixtures, where resolution is similarly enhanced following optimization of chromatographic selectivity and zone bandwidth. The conventional approach to process purification with low molecular weight solutes has frequently been based on linear scale-up of the performance of an analytical column system. In these cases, high-resolution separations can be achieved often without the burden of conformational or... [Pg.157]

Small particle size resins provide higher resolution, as demonstrated in Fig. 4.41. Low molecular weight polystyrene standards are better separated on a GIOOOHxl column packed with 5 /u,m resin than a GlOOOHg column packed with 10 /Ltm resin when compared in the same analysis time. Therefore, smaller particle size resins generally attain a better required resolution in a shorter time. In this context, SuperH columns are best, and Hhr and Hxl columns are second best. Most analyses have been carried out on these three series of H type columns. However, the performance of columns packed with smaller particle size resins is susceptible to some experimental conditions such as the sample concentration of solution, injection volume, and detector cell volume. They must be kept as low as possible to obtain the maximum resolution. Chain scissions of polymer molecules are also easier to occur in columns packed with smaller particle size resins. The flow rate should be kept low in order to prevent this problem, particularly in the analyses of high molecular weight polymers. [Pg.143]

Figure 13.22 shows the resolution of the surfactants Tween 80 and SPAN. The high resolution obtained will even allow the individual unreacted ethylene oxide oligomers to be monitored. Figure 13.23 details the resolution of many species in both new and aged cooking oil. Perhaps the most unique high resolution low molecular weight SEC separation we have been able to obtain is shown in Fig. 13.24. Using 1,2,4-trichlorobenzene as the mobile phase at 145°C with a six column 500-A set in series, we were able to resolve Cg, C, Cy, Cg, C9, Cio, and so on hydrocarbons, a separation by size of only a methylene group. Individual ethylene groups were at least partially resolved out to Cjg. This type of separation should be ideal for complex wax analysis. Figure 13.22 shows the resolution of the surfactants Tween 80 and SPAN. The high resolution obtained will even allow the individual unreacted ethylene oxide oligomers to be monitored. Figure 13.23 details the resolution of many species in both new and aged cooking oil. Perhaps the most unique high resolution low molecular weight SEC separation we have been able to obtain is shown in Fig. 13.24. Using 1,2,4-trichlorobenzene as the mobile phase at 145°C with a six column 500-A set in series, we were able to resolve Cg, C, Cy, Cg, C9, Cio, and so on hydrocarbons, a separation by size of only a methylene group. Individual ethylene groups were at least partially resolved out to Cjg. This type of separation should be ideal for complex wax analysis.
PVP K-120 peaks are distorted at the high molecular weight end for tht TSK-PW column in water and in water/methanol. The distortion is more severe in water than in water/methanol. If the distortion is caused by poor separation of the TSK GM-PW column, then the distortion should be more severe in water/methanol than in water, as it was shown earlier that the resolution should be better in water than in water/methanol. The distortion is probably caused by interaction between PVP K-120 and the TSK GM-PW column. There is a high molecular weight shoulder in the PVP K-90 peak for the TSK GM-PW column, especially in water. This may be the reason why M for PVP K 90 determined with the TSK GM-PW column are higher than from the other columns, as shown in Tables 17.3-17.6. [Pg.523]

Advances in size-exclusion chromatography, coupled with refractive index, absorption, viscosity, and lightscattering detectors, and MALDI-ToFMS, have made it possible to accurately determine molecular weight distribution (oligomer profiling), even at the relatively low values of polymeric additives (up to about 5000 Da). Advances in column design, e.g. high-resolution PS/DVB columns (> 105 plates m-1) mean that SEC can provide a valuable alternative to conventional HPLC techniques for the separation of small molecules. [Pg.733]

High-temperature high-resolution gas chromatography (HTGC) is an established technique for the separation of complex mixtures of high molecular weight compounds (HMW) which do not elute when analyzed on conventional GC columns [530]. The combination of this technique with mass spectrometry (i.e., HTGC-MS) is not so common, however, Elias et al. [530] used this novel application to evaluate and identify the occurrence of HMW tracers (> C40) from smoke aerosols. [Pg.73]


See other pages where High resolution separation column Molecular weight is mentioned: [Pg.275]    [Pg.199]    [Pg.22]    [Pg.356]    [Pg.48]    [Pg.277]    [Pg.266]    [Pg.263]    [Pg.130]    [Pg.48]    [Pg.300]    [Pg.126]    [Pg.594]    [Pg.260]    [Pg.292]    [Pg.1317]    [Pg.1278]    [Pg.196]    [Pg.29]    [Pg.30]    [Pg.108]    [Pg.221]    [Pg.335]    [Pg.210]    [Pg.240]    [Pg.176]    [Pg.195]    [Pg.201]    [Pg.259]    [Pg.259]    [Pg.261]    [Pg.264]    [Pg.106]    [Pg.131]    [Pg.403]    [Pg.26]    [Pg.48]    [Pg.168]    [Pg.190]    [Pg.191]    [Pg.193]    [Pg.18]    [Pg.196]    [Pg.25]    [Pg.1119]   
See also in sourсe #XX -- [ Pg.30 , Pg.35 , Pg.91 , Pg.112 , Pg.143 , Pg.174 , Pg.184 ]




SEARCH



High columns

Molecular columns

Molecular resolution

Molecular separations

Molecular separators

Molecular-weight resolution

Resolution column

Separation high-resolution

Separation resolution

Separator column

© 2024 chempedia.info