Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Regulation checking

Checking of NDT devices is mandatory and is strictly regulated. Checking is performed and supervised by National metrological service. The term calibration is rather new in our practice. The works on calibration of NDT equipment are presented in the block-scheme 2. [Pg.964]

Vehicle manufacturers must build cars and tmcks that operate well on available fuels. They also specify the fuel requirements of their vehicles. Euel marketers must produce fuels that operate in both new and old vehicles. The consumer, the purchaser of the fuel and the vehicle, wants the fuel to be affordable, readily available, and able to provide a high level of performance. Regulators check that fuels are labeled properly and meaninghilly and that no unwarranted claims are made. They also regulate emissions from vehicles as well as the fuels used. [Pg.178]

Figure 6. Experimental apparatus for continuous polymerization of styrene ((D) Needle valve (X) t)dlve ( ) pressure regulator check valve (— ) ther-... Figure 6. Experimental apparatus for continuous polymerization of styrene ((D) Needle valve (X) t)dlve ( ) pressure regulator check valve (— ) ther-...
What if the vacuum regulator check unit fails ... [Pg.89]

Do not use a regulator that has been dropped or shows any signs of physical abuse. If in doubt, have the regulator checked at the manufacturer s service center. [Pg.283]

Centrifugal and positive displacement stainless steel pumps are most likely used in plasticizer transfer. The pumps should have mechanical seals instead of packing glands as required by environmental regulations. Check valves should be used on pump discharges to avoid contamination by back flows. Pumps and pipes should be made from the same material as used for tank construction to avoid galvanic corrosion... [Pg.104]

Any disposal practice must be in compliance with federal, state/provincial, and local laws and regulations. State/provincial and local requirements for waste disposal may be more restrictive or otherwise different from federal laws and regulations. Check with appropriate agencies for your location. [Pg.228]

Vent/Vacuum Lines Back Pressure Regulator Check Valve... [Pg.976]

GOST 30415 specifies plans for inspection the products of different types and sets formulae for calculation of inspected numbers while applying magnetic inspection. The procedure of random inspection is predetermined to check the authenticity of the correlated relation usage and regulations are introduced to enter data file of non-destructive and parallel tests. [Pg.26]

The latest government regulations set forth under the Toxic Substances Control Act and in PubHc Health Service pubHcations should be checked before formulating new lubricants. Users of lubricants should request Material Safety Data Sheets for each substance involved plus certification of compliance from vendors. Lubricant compounders should insist on similar information from their suppHers for any additive packages. Manufacturers of both additives and lubricants commonly make toxicity checks on commercial products. [Pg.256]

A control valve consists ot a valve, an actuator, and possiblv one or more valve-control devices. The valves discussed in this section are applicable to throttling control (i.e, vviiere tlovv through the valve is regulated to anv desired amount betvv een maximum and minimum limits). Other valves such as check, isolation, and relict valves are addressed in the next subsection. As defined, control valves are automatic control devices that modify the tliiid tlovv rate as specified bv the controller. [Pg.778]

A regulator is a compact device that maintains the process variable at a specific value in spite of disturbances in load flow. It combines the functions of the measurement sensor, controher, and final control element into one self-contained device. Regulators are available to control pressure, differential pressure, temperature, flow, hquid level, and other basic process variables. They are used to control the differential across a filter press, heat exchanger, or orifice plate. Regulators are used for monitoring pressure variables for redundancy, flow check, and liquid surge relief. [Pg.793]

The unit shown on the next page in figure 4.4.1 is a somewhat simplified version of a tested, actual unit. The six gaseous feed components enter through check valves at a pressure regulated to about 4 atm higher pressure then experimental pressure, e.g., 22 atm. Six mass flow controllers set the flows and all but the nitrogen lines are secured with power to open solenoid valves (SV). [Pg.92]

In the United States, regulation of emissions from new automotive vehicles has followed the prototype-replicate route. The argument for routine annual automobile inspection is that cars should be regularly inspected for safety (brakes, lights, steering, and tires) and that the additional time and cost required to check the car s emission control system during the same inspection will be minimal. Such an inspection certainly pinpoints cars whose emission control system has been removed, altered, damaged, or deteriorated and force such defects to be remedied. The question is whether... [Pg.423]

On compressors with gas seals, it is very desirable to use the contract buffer gas skid. Use of the skid provides the contract filtration level as well as having the regulators sized for contract conditions and checks the buffer gas skid functioning. Most shop systems are built of surplus parts and tend to use manual regulation, which may lead to serious test stand problems. If the skid is not available, it is important to have the vendor provide a comprehensive plan on how the shop buffer gas will be set up. [Pg.409]

Ensure reading on gauge does not increase as the regulator valve is closed Check for crawl due to wear on the regulator valve and seat assembly Ensure no leak between cylinder and regulator... [Pg.273]


See other pages where Regulation checking is mentioned: [Pg.251]    [Pg.922]    [Pg.926]    [Pg.127]    [Pg.420]    [Pg.696]    [Pg.251]    [Pg.922]    [Pg.926]    [Pg.127]    [Pg.420]    [Pg.696]    [Pg.3]    [Pg.91]    [Pg.238]    [Pg.312]    [Pg.250]    [Pg.444]    [Pg.234]    [Pg.513]    [Pg.100]    [Pg.97]    [Pg.48]    [Pg.457]    [Pg.1972]    [Pg.67]    [Pg.768]    [Pg.562]    [Pg.31]    [Pg.536]    [Pg.280]    [Pg.111]    [Pg.111]    [Pg.461]    [Pg.483]    [Pg.485]    [Pg.105]    [Pg.94]    [Pg.321]   