The CamuS system consists of a number of components, both hardware and software, as shown in Figure 1. The hub of the system is the data acquisition unit, which collects and stores ultrasonic data in the form of RF waveforms. An accurate probe position monitor provides information on the location and orientation of the probe as it is scanned over the test object. Software tools have been developed to provide assistance to the user with preparing inspection procedures according to the requirements of prEN1714 with visualising the data, in relation to the test object with making measurements of any indications present and with classifying indications. [Pg.765]

To detect tlie initial apparent non-RRKM decay, one has to monitor the reaction at short times. This can be perfomied by studying the unimolecular decomposition at high pressures, where collisional stabilization competes with the rate of IVR. The first successful detection of apparent non-RRKM behaviour was accomplished by Rabinovitch and co-workers [115], who used chemical activation to prepare vibrationally excited hexafluorobicyclopropyl-d2 ... [Pg.1035]

Undeniably, one of the most important teclmological achievements in the last half of this century is the microelectronics industry, the computer being one of its outstanding products. Essential to current and fiiture advances is the quality of the semiconductor materials used to construct vital electronic components. For example, ultra-clean silicon wafers are needed. Raman spectroscopy contributes to this task as a monitor, in real time, of the composition of the standard SC-1 cleaning solution (a mixture of water, H2O2 and NH OH) [175] that is essential to preparing the ultra-clean wafers. [Pg.1217]

The cinnamate ester prepared as above (23.2 g. 79 mmol) was added as a solid slowly to refluxing xylene (500 ml) over a period of 3 h at a rate that prevented accumulation of unreacted azidocinnamate in the solution (monitored by gas evolution through a gas bubbler). The solution was refluxed for an additional 2 h after gas evolution ceased. The reaction mixture was cooled and the solvent removed in vacuo. The residue was recrystallized from methanol to give pure product (20.7 g, 99% yield). [Pg.47]

A quantitative analysis for NH3 in several household cleaning products is carried out by titrating with a standard solution of HGl. The titration s progress is followed thermometrically by monitoring the temperature of the titration mixture as a function of the volume of added titrant. Household cleaning products may contain other basic components, such as sodium citrate or sodium carbonate, that will also be titrated by HGl. By comparing titration curves for prepared samples of NH3 to titration curves for the samples, it is possible to determine that portion of the thermometric titration curve due to the neutralization of NH3. [Pg.358]

Sensitivity Sensitivity in flame atomic emission is strongly influenced by the temperature of the excitation source and the composition of the sample matrix. Normally, sensitivity is optimized by aspirating a standard solution and adjusting the flame s composition and the height from which emission is monitored until the emission intensity is maximized. Chemical interferences, when present, decrease the sensitivity of the analysis. With plasma emission, sensitivity is less influenced by the sample matrix. In some cases, for example, a plasma calibration curve prepared using standards in a matrix of distilled water can be used for samples with more complex matrices. [Pg.440]

Samples of analyte are dissolved in a suitable solvent and placed on the IR card. After the solvent evaporates, the sample s spectrum is obtained. Because the thickness of the PE or PTEE film is not uniform, the primary use for IR cards has been for qualitative analysis. Zhao and Malinowski showed how a quantitative analysis for polystyrene could be performed by adding an internal standard of KSCN to the sample. Polystyrene was monitored at 1494 cm- and KSCN at 2064 cm-. Standard solutions were prepared by placing weighed portions of polystyrene in a 10-mL volumetric flask and diluting to volume with a solution of 10 g/L KSCN in... [Pg.453]

Ion-selective electrodes can be incorporated in flow cells to monitor the concentration of an analyte in standards and samples that are pumped through the flow cell. As the analyte passes through the cell, a potential spike is recorded instead of a steady-state potential. The concentration of K+ in serum has been determined in this fashion, using standards prepared in a matrix of 0.014 M NaCl. ... [Pg.536]

Procedure. Prepare a set of external standards containing 0.5 g/L to 3.0 g/L creatinine (in 5 mM H2SO4) using a stock solution of 10.00 g/L creatinine in 5 mM H2SO4. In addition, prepare a solution of 1.00 x 10 M sodium picrate. Pipet 25.00 mL of 0.20 M NaOH, adjusted to an ionic strength of 1.00 M using Na2S04, into a thermostated reaction cell at 25 °C. Add 0.500 mL of the 1.00 x 10 M picrate solution to the reaction cell. Suspend a picrate ion-selective electrode in the solution, and monitor the potential until it stabilizes. When the potential is stable, add 2.00 mL of a... [Pg.632]

Analysis of Standards The analysis of a standard containing a known concentration of analyte also can be used to monitor a system s state of statistical control. Ideally, a standard reference material (SRM) should be used, provided that the matrix of the SRM is similar to that of the samples being analyzed. A variety of appropriate SRMs are available from the National Institute of Standards and Technology (NIST). If a suitable SRM is not available, then an independently prepared synthetic sample can be used if it is prepared from reagents of known purity. At a minimum, a standardization of the method is verified by periodically analyzing one of the calibration standards. In all cases, the analyte s experimentally determined concentration in the standard must fall within predetermined limits if the system is to be considered under statistical control. [Pg.710]

The use of several QA/QC methods is described in this article, including control charts for monitoring the concentration of solutions of thiosulfate that have been prepared and stored with and without proper preservation the use of method blanks and standard samples to determine the presence of determinate error and to establish single-operator characteristics and the use of spiked samples and recoveries to identify the presence of determinate errors associated with collecting and analyzing samples. [Pg.722]

Industrial Hygiene Monitoring Manualfor Petroleum Kefineries and Selected Petrochemical Operations, prepared for American Petroleum Institute, contract no. LER-40-73, by Clayton Environmental Consultants, Inc., API, Washington, D.C., p. 69. [Pg.410]

Another furnace that does not require fuel preparation is the stoker boiler, which was used by New York State Electric Gas Corporation (NYSEG) in its TDE tests. At NYSEG, the stoker boiler, which has a 1649°C (3000°E) flame temperature (as does the cyclone boiler), has routinely blended low quaUty coal, and more recently, wood chips with its standard coal to reduce fuel costs and improve combustion efficiency. In the tire-chip tests, NYSEG burned approximately 1100 t of tire chips (smaller than 5x5 cm) mixed with coal and monitored the emissions. The company determined that the emissions were similar to those from burning coal alone. In a second test-bum of 1900 t of TDE, magnetic separation equipment removed metal from the resulting ash, so that it could be recycled as a winter traction agent for roadways. [Pg.109]

Sample preparation is straightforward for a scattering process such as Raman spectroscopy. Sample containers can be of glass or quartz, which are weak Raman scatterers, and aqueous solutions pose no problems. Raman microprobes have a spatial resolution of - 1 //m, much better than the diffraction limit imposed on ir microscopes (213). Eiber-optic probes can be used in process monitoring (214). [Pg.318]

Biological indicators for steam sterilization utilize bacillus stearothermophilus. In monitoring industrial cycles, a sufficient number of preparations each having a known degree of resistance are added to the load and retrieved after exposure, and cultured. [Pg.408]

Standards used to constmct a cahbration curve must be prepared such that the matrix of the standard is identical to the sample s matrix because the values of the parameters k and b associated with a linear cahbration curve are matrix dependent. Many areas of chemical analysis are plagued by matrix effects, and it is often difficult to duphcate the sample matrix when preparing external standards. Because it is desirable to eliminate matrix effects, cahbration in the sample matrix itself can be performed. This approach is called the standard addition method (SAM) (14). In this method, the standards are added to the sample matrix and the response of the analyte plus the standard is monitored as a function of the added amount of the standard. The initial response is assumed to be Rq, and the relationship between the response and the concentration of the analyte is... [Pg.427]


See other pages where Preparation monitoring is mentioned: [Pg.150]    [Pg.237]    [Pg.253]    [Pg.588]    [Pg.114]    [Pg.150]    [Pg.237]    [Pg.253]    [Pg.588]    [Pg.114]    [Pg.721]    [Pg.941]    [Pg.123]    [Pg.280]    [Pg.362]    [Pg.396]    [Pg.586]    [Pg.655]    [Pg.403]    [Pg.49]    [Pg.198]    [Pg.356]    [Pg.507]    [Pg.110]    [Pg.237]    [Pg.235]    [Pg.314]    [Pg.153]    [Pg.202]    [Pg.85]    [Pg.392]    [Pg.404]    [Pg.407]    [Pg.8]    [Pg.315]    [Pg.405]    [Pg.102]    [Pg.197]    [Pg.335]    [Pg.394]   
See also in sourсe #XX -- [ Pg.11 ]