Power supply unit

Figure 11. Illustrates the transformer-rectifier of the power supply unit. Figure 11. Illustrates the transformer-rectifier of the power supply unit.
Electrical power supply units vary considerably among manufacturers. Power consumption and ozone-generation capacity are proportional to both voltage and frequency. There are two methods to control the output of an ozone generator vary voltage or vary frequency. Three common electrical power supply configurations are used in commercial equipment ... [Pg.492]

For energy security reasons, the presence of an auxiliary power supply unit is necessary. This unit can be preferably either a hydrogen internal combustion engine (H2 ICE) or a fuel cell of corresponding capacity to meet at least the minimum needs of the system. In this case, the system is an autonomous power plant. Figure 5.11 shows a stand-alone wind-hydrogen system that is autonomous. The dashed line in some parts of it implies that these connections may not exist as well. The DC/AC converter/controller should have the capability to operate vice versa and power up the lines through the power controller. [Pg.175]

Initially, the control units were quite clumsy and offered uncountable manipulation options. It was often the case that only physicists were able to handle and use them. With the Introduction of PCs the requirements In regard to the control units became ever greater. At first, they were fitted with Interfaces for linkage to the computer. Attempts were made later to equip a PC with an additional measurement circuit board for sensor operation. Today s sensors are In fact transmitters equipped with an electrical power supply unit attached direct at the atmosphere side communication with a PC from that point Is via the standard computer ports (RS 232, RS 485). Operating convenience Is achieved by the software which runs on the PC. [Pg.95]

Power supply for high-voltage electrophoresis LKB Biochrom 2103 power supply unit, LKB Instruments Ltd., 232 Addington Road, Selsdon, South Croydon, Surrey CR2 8YD, U.K. This instrument may be used to run gels at constant voltage, constant current or constant power. [Pg.304]

The installation comprises laser emitter, laser power-supply unit, water-air cooling system and guiding computer. Total weight of the installation is 40 kg consumed power is 3 kW from power network 220 V. The installation capacity reaches to 2 m per hour the distance from emitter to surface to be decontaminated can attain 1.5 m. Laser emitter is installed at a remotely operated rotator. [Pg.389]

The two primary components required for gel electrophoresis are a buffer-filled electrophoresis chamber (or box) and a separate power supply unit providing constant electrical current. [Pg.181]

Uninterruptible power supply unit to be added to control room cost 60,000 each... [Pg.287]

The experimental set-up is a vacuum unit for pulsed deposition of carbon film from carbon-based plasmas at a plasma density of lO to 10 cm , ionization rate of about 95% and pulse frequency varied from 1 to 30 Hz. The pulse duration was 100 ps. Figure 11.3 schematically illustrates the plasma deposition system [10]. The system consists of a high purity graphite cathode (1), anode (2), ignition electrodes (3,4) with dielectric separator (5), second anode of auxiliary discharge (6) and substrate holder (7). The capacitors Ci and C2 are connected to a power supply unit with... [Pg.224]

Other variations of the above conhgurations are possible considering that the energy recharging the battery could comes from the electric network or other power supply units, while the car is parked or, however, not in use [3]. [Pg.160]

The irradiation system consisted of an Optical Module X (model SX-UI500 MQQ) and a power supply unit (model BA-H500) (360 nm cutoff, 70-450 mW/cm, and the distances between the collimator lens and the quartz cuvette were 40-160 cm) was obtained from USIO Electronics (Tokyo, Japan). The light power meter was purchased from Advantest (Tokyo, Japan). A Lumat LB 9501 (Berthold, Wildbad, Germany) was used to measure the CL with a round-bottom glass tube (75 x 12 mm... [Pg.179]

The size and structural features of a medical cyclotron vary from vendor to vendor and so require rooms of various dimensions. A room of 25 x 25 feet should be adequate for most compact medical cyclotrons and should be equipped with a floor drain. The power supply unit may be installed in the cyclotron room or in a separate room. [Pg.194]

The cooling system is required because of the heat generated by the electromagnet of the cyclotron and power supply unit associated with it. It consists of chillers with heat exchanger/deionizer water system that recirculates cooled water between the cyclotron and the power supply. The temperature of the system is maintained at around 7-15° C, depending on the type of cyclotron from a vendor. Chillers are installed in a room adjacent to the cyclotron and power supply rooms, although they are sometimes installed on the roof of the cyclotron building. The room size for chillers should be of the size 10 x 10 feet and a floor drain is required in the room. [Pg.195]

The automation of this system essentially resided in developing an automatic sample injector. The designers of the system used an automatic device for introducing solid samples into a Pye-Unicam gas chromatograph. The automatic sample introducing device designed by Coulter and Thompson [69] is illustrated in Fig. 3.6. Power supply unit 1... [Pg.99]

In addition to the actual stack and the power supply unit, an electrodialysis plant consists of several components essential for proper operation, such as pumps, process monitoring and control devices, feed solution pretreatment systems, etc.. There are two operating modes for the electrodialytic process described in the literature [44]. The first is referred to as the unidirectionally operated electrodialysis plant and the second is a reversed polarity operated electrodialysis plant [7]. A flow diagram of a typical unidirectional operated electrodialysis plant is shown in Figure 10. [Pg.516]

Underwriters Laboratory (USA). Unless noted otherwise. Uninterruptible power supply unit. Undervoltage. [Pg.515]

Power supplies - If there is an outage of local power an alternative may be provided so that service can continue. The substitute technology is not dependent on mains supply and may involve a mechanical generator or battery. It is also common for servers to be fed from two separate power supply units which are themselves fed from separate mains distribution circuits. [Pg.104]

Pulsed DC Power supply unit This is one of the important subsystems of the EMM semp. It provides a pulsed power supply to the workpiece (anode) and microtool (cathode) during the dissolution process. The pulse supplied consists of various parameters such as voltage amplitude, current, pulse frequency, and duty ratio. Accuracy of the machined microfeature is directly affected by the parameters of the pulse hence, pulse power specifications plays a major role in EMM. [Pg.86]


See other pages where Power supply unit is mentioned: [Pg.857]    [Pg.74]    [Pg.169]    [Pg.176]    [Pg.281]    [Pg.462]    [Pg.53]    [Pg.420]    [Pg.427]    [Pg.171]    [Pg.170]    [Pg.175]    [Pg.980]    [Pg.53]    [Pg.145]    [Pg.264]    [Pg.269]    [Pg.100]    [Pg.137]    [Pg.188]    [Pg.120]    [Pg.125]    [Pg.126]    [Pg.127]    [Pg.127]    [Pg.125]    [Pg.719]    [Pg.3112]    [Pg.872]    [Pg.226]    [Pg.156]    [Pg.227]   
See also in sourсe #XX -- [ Pg.271 ]