Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Potential difference direction

Typical Applications EPR spectra were obtained for both the interfacial reduction of 7,7,8,8,-tetracyanoquinodi-methane (TCNQ) and oxidation of tetrathi-afulvalene (TTF), when dissolved in DCE by the aqueous phase ferri/ferrocyanide redox couple, following the application of a potential difference directly to the liquid I liquid interface. Previous work [111, 112] suggested that a charge-transfer process occurs at the liquid liquid interface, due to the heterogeneous reduction of TCNQ by the aqueous couple,... [Pg.744]

Given that fuel cells generate electrical potential difference directly from Gibb s potential rather than by heat exchange cycles between two focuses at different temperatures i.e. fuel cells are not limited by Carnot heat cycle, the reversible energy efficiency of a DEFC, calculated as the ratio between the free energy and enthalpy at the equihbiium potential ... [Pg.58]

Hall effect If a current (I) is passed through a conducting crystal in a direction perpendicular to that of an applied magnetic field (H), the conductor develops a potential (V) between the faces which are mutually perpendicular to both the direction of the current and the magnetic field. This is known as the Hall effect the magnitude of the potential difference is given by... [Pg.199]

In accordance with equation (Bl.20.1). one can plot the so-called surface force parameter, P = F(D) / 2 i R, versus D. This allows comparison of different direct force measurements in temis of intemiolecular potentials fV(D), i.e. independent of a particular contact geometry. Figure B 1.20.2 shows an example of the attractive van der Waals force measured between two curved mica surfaces of radius i 10 nun. [Pg.1732]

Wlien an electrical coimection is made between two metal surfaces, a contact potential difference arises from the transfer of electrons from the metal of lower work function to the second metal until their Femii levels line up. The difference in contact potential between the two metals is just equal to the difference in their respective work fiinctions. In the absence of an applied emf, there is electric field between two parallel metal plates arranged as a capacitor. If a potential is applied, the field can be eliminated and at this point tire potential equals the contact potential difference of tlie two metal plates. If one plate of known work fiinction is used as a reference electrode, the work function of the second plate can be detennined by measuring tliis applied potential between the plates [ ]. One can detemiine the zero-electric-field condition between the two parallel plates by measuring directly the tendency for charge to flow through the external circuit. This is called the static capacitor method [59]. [Pg.1894]

Statistically, in a high-pressure region, an ion will be struck by neutral molecules randomly from all angles. The ion receives as many collisions from behind as in front and as many collisions from one side as from the other. Therefore, it can be expected that the overall forward motion of the ion will be maintained but that the trajectory will be chaotic and similar to Brownian motion (Figure 49.4b). Overall, the ion trajectory can be expected to be approximately along the line of its initial velocity direction, since it is still influenced by the applied potential difference V. [Pg.375]

Barium carbonate also reacts with titania to form barium titanate [12047-27-7] BaTiO, a ferroelectric material with a very high dielectric constant (see Ferroelectrics). Barium titanate is best manufactured as a single-phase composition by a soHd-state sintering technique. The asymmetrical perovskite stmcture of the titanate develops a potential difference when compressed in specific crystallographic directions, and vice versa. This material is most widely used for its strong piezoelectric characteristics in transducers for ultrasonic technical appHcations such as the emulsification of Hquids, mixing of powders and paints, and homogenization of milk, or in sonar devices (see Piezoelectrics Ultrasonics). [Pg.480]

In the presence of 6-iodo-l-phenyl-l-hexyne, the current increases in the cathodic (negative potential going) direction because the hexyne catalyticaHy regenerates the nickel(II) complex. The absence of the nickel(I) complex precludes an anodic wave upon reversal of the sweep direction there is nothing to reduce. If the catalytic process were slow enough it would be possible to recover the anodic wave by increasing the sweep rate to a value so fast that the reduced species (the nickel(I) complex) would be reoxidized before it could react with the hexyne. A quantitative treatment of the data, collected at several sweep rates, could then be used to calculate the rate constant for the catalytic reaction at the electrode surface. Such rate constants may be substantially different from those measured in the bulk of the solution. The chemical and electrochemical reactions involved are... [Pg.55]

Piezoelectric Transducers Certain ciystals produce a potential difference between their surfaces when stressed in appropriate directions. Piezoelectric pressure transducers generate a potential difference proportional to a pressure-generated stress. Because of the extremely high electrical impedance of piezoelectric crystals at low frequency, these transducers are usually not suitable for measurement of static process pressures. [Pg.762]

The cross-flow-tower manufacturer may effec tively reduce the tower characteristic at very low approaches by increasing the air quantity to give a lower L/G ratio. The increase in air flow is not necessarily achieved by increasing the air velocity but primarily by lengthening the tower to increase the air-flow cross-sec tional area. It appears then that the cross-flow fill can be made progressivelv longer in the direction perpendicular to the air flow and shorter in the direction of the air flow until it almost loses its inherent potential-difference disadvantage. However, as this is done, fan power consumption increases. [Pg.1164]

This handbook deals only with systems involving metallic materials and electrolytes. Both partners to the reaction are conductors. In corrosion reactions a partial electrochemical step occurs that is influenced by electrical variables. These include the electric current I flowing through the metal/electrolyte phase boundary, and the potential difference A( = 0, - arising at the interface. and represent the electric potentials of the partners to the reaction immediately at the interface. The potential difference A0 is not directly measurable. Therefore, instead the voltage U of the cell Me /metal/electrolyte/reference electrode/Me is measured as the conventional electrode potential of the metal. The connection to the voltmeter is made of the same conductor metal Me. The potential difference - 0 is negligibly small then since A0g = 0b - 0ei ... [Pg.29]

This result is immediately confirmed by the results given in Fig. 3-3. A steel electrode was cathodically polarized in a soil sludge. The potential was measured with a capillary probe IR-free as E, and without a probe as E2. The difference directly... [Pg.89]

The first term in Eq. (3-27) represents the voltage drop between the reference electrode over the pipeline and the pipe surface. The second term represents the potential difference AU measured at the soil surface (ground level) perpendicular (directly above) to the pipeline. Average values of the values measured to the left and right of the pipeline are to be used (see Fig. 3-24) [2]. In this way stray IR components can be eliminated. The third term comprises the current densities where, in the switched-off state of the protection installation, there is a cell current J. In the normal case J = 0 and also correspondingly AU f = 0 as well as = t/ ff On... [Pg.95]

The simplest procedure in studying galvanic corrosion is a measurement of the open-circuit potential difference between the metals in a couple in the environment under consideration. This will at least indicate the probable direction of any galvanic effect although no information is provided on the rate. A better procedure is to make similar open-circuit potential measurements between the individual metals and some appropriate reference electrode, which will yield the same information and will also permit obser-... [Pg.1018]

An aqueous electrolyte solution consists of a variety of charged and uncharged species, e.g. cations, anions, water dipoles, organic molecules, trace impurities, etc. which under equilibrium conditions are randomly oriented so that within the solution there is no net preferentially directed field. However, under the influence of a potential difference, the charge will be transported through the solution by cations and anions that migrate to... [Pg.1165]

If the circuit is broken after the e.m.f. has been applied, it will be observed that the reading on the voltmeter is at first fairly steady, and then decreases, more or less rapidly, to zero. The cell is now clearly behaving as a source of current, and is said to exert a back or counter or polarisation e.m.f., since the latter acts in a direction opposite to that of the applied e.m.f. This back e.m.f. arises from the accumulation of oxygen and hydrogen at the anode and cathode respectively two gas electrodes are consequently formed, and the potential difference between them opposes the applied e.m.f. When the primary current from the battery is shut off, the cell produces a moderately steady current until the gases at the electrodes are either used up or have diffused away the voltage then falls to zero. This back e.m.f. is present even when the current from the battery passes through the cell and accounts for the shape of the curve in Fig. 12.1. [Pg.505]

There are different techniques to evaluate the quantitative stress level in prototype and production products. They can predict potential problems. Included is the use of electrical resistance strain gauges bonded on the surface of the product. This popular method identifies external and internal stresses. Their various configurations are made to identify stresses in different directions. This technique has been extensively used for over a half century on very small to very large products such as toys to airplanes. There is the optical strain measurement system that is based on the principles of optical interference. It uses Moire, laser, or holographic interferometry (2,3,20). [Pg.302]


See other pages where Potential difference direction is mentioned: [Pg.119]    [Pg.1323]    [Pg.6]    [Pg.55]    [Pg.194]    [Pg.399]    [Pg.226]    [Pg.179]    [Pg.119]    [Pg.1323]    [Pg.6]    [Pg.55]    [Pg.194]    [Pg.399]    [Pg.226]    [Pg.179]    [Pg.155]    [Pg.681]    [Pg.589]    [Pg.600]    [Pg.371]    [Pg.150]    [Pg.311]    [Pg.248]    [Pg.545]    [Pg.277]    [Pg.55]    [Pg.81]    [Pg.162]    [Pg.38]    [Pg.404]    [Pg.221]    [Pg.928]    [Pg.1251]    [Pg.1374]    [Pg.141]    [Pg.234]    [Pg.61]    [Pg.440]    [Pg.362]    [Pg.429]   
See also in sourсe #XX -- [ Pg.29 ]




SEARCH



Difference potential

Directional difference

© 2024 chempedia.info