Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Positive compliance

Figure 2.5. Measurement results and their measurement uncertainties near a compliance limit. A clearly fails, and D clearly passes. B does not fail if positive noncompliance is required for failure, but otherwise fails. C does not pass if positive compliance is required, but otherwise does pass. Figure 2.5. Measurement results and their measurement uncertainties near a compliance limit. A clearly fails, and D clearly passes. B does not fail if positive noncompliance is required for failure, but otherwise fails. C does not pass if positive compliance is required, but otherwise does pass.
Similar arguments apply when considering a result against a limit. The limit may be a legal requirement that must be achieved or not exceeded, or it may be an internal specification. The risks of noncompliance might require evidence that the probability the test item does not comply is very small and insignificant ( positive compliance, line a in figure 7.4) or, alternatively,... [Pg.209]

Crack extension is often observed to vary significantly at the same nominal value of AK (= Y AOpos Tta) for different values of R-ratio. Elber [26] was the first to explain this observation for metals in terms of the crack closure phenomenon. He determined, by measuring specimen compliance, that fatigue cracks open and close at the crack tip at positive values of stress due to contact between crack surfaces behind the crack tip. For elastic fatigue conditions it is generally found that P p = P, and Kop = K, where P is the applied load. [Pg.493]

Water sample collection techniques differ depending on the source being tested. The minimum number of water samples collected from a distribution system which are examined each month for coliforms is a function of the population. For example, the minimum number required for populations of 1,000 and 100,000 are 2 and 100, respectively. To ascertain compliance with the bacteriological requirements of drinking water standards, a certain number of positive tests must not be exceeded. When 10-ml standard portions are examined, not more than 10 percent in any month should be positive (that is, the upper limit of coliform density is an average of one per 100 ml). [Pg.461]

The standard does not address the question of who should pay for the required PPE. Elowever, in a compliance memorandum OSHA has clarified its position that in most cases the employer should provide and pay for the employee s PPE. The OSHA memorandum explains,... [Pg.125]

You can show compliance with this requirement by defining where the auditors fit into the organization by means of an organization chart and by giving position titles in the reports of the audit. [Pg.517]

This mathematical condition can be replaced by the following physical argument. If only one normal stress is applied at a time, the corresponding strain is determined by the diagonal elements of the compliance matrix. Thus, those elements must be positive, that is,... [Pg.68]

In CRA with alcohol-dependent patients, reinforcement of disulfiram compliance is one of the primary components of treatment, such that use of alcohol loses its reinforcing aspects and, in fact, becomes aversive. Furthermore, reinforcement from other sources is increased. Positive reinforcement for not drinking comes in the form of scheduhng other recreational activities and reorganizing daily life by breaking down pracrical barriers. For example, the therapist may assist the patient in obtaining a telephone, a place to hve, or transportation to treatment. [Pg.346]

The positive values obtained in practically all cases indicate that all these models may be plausible representations of the data and indeed, the correlation coefBcients, R, are greater than 0.9. Thus, statistical compliance is not a sufficient basis for model discrimination. Specifically, the thermodynamic consistency of the estimates, as proposed by Boudart et al. [3], is appropriate further scrutinizing criterion during kinetic modelling and has been gainfully employed in other reactions [4-6]. [Pg.543]

An additional requirement not noted in Table 1 is compliance with GLP7 These practices establish a paper trail for all procedures involved in the determination of residues. With regard to immunoassays, GLPs require calibration of measurement devices such as adjustable pipettors and dedicated spectrophotometers. Computer software output, as noted above, must be verified prior to use. This process can be simplified by limiting the application of specialized software to the operation of an instrument and carrying out the residue calculations in a broadly available spreadsheet such as Excel. On a positive note, in recent years, the software accompanying most microtiter plate readers has become generally easier to use and usually incorporates internal spreadsheets that are compatible with external systems. [Pg.723]

The chemisorbed reaction product can be characterized by more shallow positioning of the energy level with respect to the bottom of conductivity band if contrasted to Z (A ) which results in emission of electron into the conductivity band in compliance with reaction... [Pg.144]

In the recently released book on worldwide compliance issues (Adherence to Long-term Therapies, Evidence for Action),7 published by the World Health Organization, researchers indicate that the problem of noncompliance is worse in countries in the developing world than in countries in the industrialized world. Many parts of the United States have similar morbidity and mortality rates as countries in the Third World.8 Specific disease states may have significant additional noncompliance ramifications due to the development of drug-resistant strains of bacteria.9 Many times what is necessary is referral to specific clinicians for individualized treatment and monitoring to enhance compliance. The case histories provided in this text will allow you to follow what others have done in similar situations to optimally help patients succeed in improving compliance rates and subsequent positive health outcomes. [Pg.4]

Emphasize the importance of treatment regimen compliance to ensure positive results. [Pg.966]

In many clinical trials a positive control of a clinically established drug is often used for comparison purposes for example, a novel selective serotonin reuptake inhibitor (SSRI), may be compared with a more established tricyclic antidepressant, such as imipramine. The aim is to see whether the new SSRI is more efficacious or has fewer adverse side effects than the more established tricyclic (Chapter 12). In many such comparisons the new and older treatments are equally efficacious at relieving depression, but the newer drugs display fewer side effects this means that they are better tolerated by patients, so that they are more willing to continue taking the tablets. The high rates of compliance also mean that, in overall terms, newer drugs with fewer side effects tend to be more efficacious. [Pg.38]

The above experimental data (Figs. 1 and 2) allow us to estimate the possibility for taking place the oxygen reduction process on PANI catalyst. If the special procedure is not taken to withdraw oxygen out of solution, PANI electrode in 1 M HC1 usually demonstrates a potential of about 0.6 V (SHE). In compliance with the Fig. 1 the position of the reduction peak might be at 0. 28 V. From the data of the standard potentials for the following reaction ... [Pg.113]

These specific, and other broader, concerns in corporate compliance with TSCA s requirements were discussed by Diamond Shamrock Corporation s D. Harlow. He described how corporate structures and procedures, including those for research and development, for companies of all sizes, have been impacted by TSCA. These impacts are generally positive in that they reflect greatly increased awareness, resources and responsiveness to questions of chemicals effects on health and environment. These benefits are seen to be in balance with their costs, expressed in the increased costs of products and services. [Pg.228]


See other pages where Positive compliance is mentioned: [Pg.806]    [Pg.36]    [Pg.37]    [Pg.209]    [Pg.806]    [Pg.36]    [Pg.37]    [Pg.209]    [Pg.517]    [Pg.1944]    [Pg.213]    [Pg.263]    [Pg.263]    [Pg.146]    [Pg.515]    [Pg.68]    [Pg.99]    [Pg.447]    [Pg.118]    [Pg.236]    [Pg.231]    [Pg.364]    [Pg.125]    [Pg.129]    [Pg.130]    [Pg.464]    [Pg.153]    [Pg.231]    [Pg.550]    [Pg.388]    [Pg.64]    [Pg.75]    [Pg.113]    [Pg.114]    [Pg.143]    [Pg.153]    [Pg.153]   
See also in sourсe #XX -- [ Pg.36 , Pg.37 , Pg.209 ]




SEARCH



© 2024 chempedia.info