Polymers instrumentation

Meruva, N.K. Metz, L.A. Goode, S.R. Morgan, S.L. UV laser pyrolysis fast gas chromatography/time-of-flight mass spectrometry for rapid characterization of synthetic polymers Instrument development. J. Anal. Appl. Pyrol. 2004, 71, 313-325. [Pg.1859]

The radiation and temperature dependent mechanical properties of viscoelastic materials (modulus and loss) are of great interest throughout the plastics, polymer, and rubber from initial design to routine production. There are a number of laboratory research instruments are available to determine these properties. All these hardness tests conducted on polymeric materials involve the penetration of the sample under consideration by loaded spheres or other geometric shapes [1]. Most of these tests are to some extent arbitrary because the penetration of an indenter into viscoelastic material increases with time. For example, standard durometer test (the "Shore A") is widely used to measure the static "hardness" or resistance to indentation. However, it does not measure basic material properties, and its results depend on the specimen geometry (it is difficult to make available the identity of the initial position of the devices on cylinder or spherical surfaces while measuring) and test conditions, and some arbitrary time must be selected to compare different materials. [Pg.239]

A recent design of the maximum bubble pressure instrument for measurement of dynamic surface tension allows resolution in the millisecond time frame [119, 120]. This was accomplished by increasing the system volume relative to that of the bubble and by using electric and acoustic sensors to track the bubble formation frequency. Miller and co-workers also assessed the hydrodynamic effects arising at short bubble formation times with experiments on very viscous liquids [121]. They proposed a correction procedure to improve reliability at short times. This technique is applicable to the study of surfactant and polymer adsorption from solution [101, 120]. [Pg.35]

The presence of surface conductance behind the slip plane alters the relationships between the various electrokinetic phenomena [83, 84] further complications arise in solvent mixtures [85]. Surface conductance can have a profound effect on the streaming current and electrophoretic mobility of polymer latices [86, 87]. In order to obtain an accurate interpretation of the electrostatic properties of a suspension, one must perform more than one type of electrokinetic experiment. One novel approach is to measure electrophoretic mobility and dielectric spectroscopy in a single instrument [88]. [Pg.189]

Photomultipliers are used to measure the intensity of the scattered light. The output is compared to that of a second photocell located in the light trap which measures the intensity of the incident beam. In this way the ratio [J q is measured directly with built-in compensation for any variations in the source. When filters are used for measuring depolarization, their effect on the sensitivity of the photomultiplier and its output must also be considered. Instrument calibration can be accomplished using well-characterized polymer solutions, dispersions of colloidal silica, or opalescent glass as standards. [Pg.692]

Instrumentation wires contain multiple pairs of conductors, each insulated with dame-retardant PVC and with an overall dame-retardant PVC jacket (5). Eor distribution wires polyethylene or ethylene—propylene mbber are the polymers of choice (Eig. 2c). A typical design for aerial self-supportingwires that employs PE and PVC, is shown in Eigure 2d. [Pg.323]

The realization of sensitive bioanalytical methods for measuring dmg and metaboUte concentrations in plasma and other biological fluids (see Automatic INSTRUMENTATION BlosENSORs) and the development of biocompatible polymers that can be tailor made with a wide range of predictable physical properties (see Prosthetic and biomedical devices) have revolutionized the development of pharmaceuticals (qv). Such bioanalytical techniques permit the characterization of pharmacokinetics, ie, the fate of a dmg in the plasma and body as a function of time. The pharmacokinetics of a dmg encompass absorption from the physiological site, distribution to the various compartments of the body, metaboHsm (if any), and excretion from the body (ADME). Clearance is the rate of removal of a dmg from the body and is the sum of all rates of clearance including metaboHsm, elimination, and excretion. [Pg.224]

The study of acid-base interaction is an important branch of interfacial science. These interactions are widely exploited in several practical applications such as adhesion and adsorption processes. Most of the current studies in this area are based on calorimetric studies or wetting measurements or peel test measurements. While these studies have been instrumental in the understanding of these interfacial interactions, to a certain extent the interpretation of the results of these studies has been largely empirical. The recent advances in the theory and experiments of contact mechanics could be potentially employed to better understand and measure the molecular level acid-base interactions. One of the following two experimental procedures could be utilized (1) Polymers with different levels of acidic and basic chemical constitution can be coated on to elastomeric caps, as described in Section 4.2.1, and the adhesion between these layers can be measured using the JKR technique and Eqs. 11 or 30 as appropriate. For example, poly(p-amino styrene) and poly(p-hydroxy carbonyl styrene) can be coated on to PDMS-ox, and be used as acidic and basic surfaces, respectively, to study the acid-base interactions. (2) Another approach is to graft acidic or basic macromers onto a weakly crosslinked polyisoprene or polybutadiene elastomeric networks, and use these elastomeric networks in the JKR studies as described in Section 4.2.1. [Pg.134]

Although the OTHdC has several unique applications in polymer analysis, this technique has several limitations. First, it requires the instrumentation of capillary HPLC, especially the injector and detector, which is not as popular as packed column chromatography at this time. Second, as discussed previously, the separation range of a uniform capillary column is rather narrow. Third, it is difficult to couple capillary columns with different sizes together as SEC columns. [Pg.601]

Another advantage of HdC is its generosity in terms of mobile-phase selection. The polymer size and solution properties of a polymer can be studied using HdC, especially OTHdC, in almost any solvent. In SEC, by comparison, the packing material and mobile phase have to be selected to prevent the nonsize exclusion effect. Because the instrumentation of HdC is similar to SEC, and the packing material and columns have become available commercially, this technique will gain in popularity. [Pg.608]

In this present chapter, the applications of multidimensional chromatography using various types of coupled techniques for the analysis of industrial and polymer samples, and polymer additives, are described in detail. The specific applications are organized by technique and a limited amount of detail is given for the various instrumental setups, since these are described elsewhere in other chapters of this volume. [Pg.304]

Therefore, if processability is to be measured on a regular basis, it would be extremely useful if a piece of equipment was available that could measure the dynamic properties under realistic operating conditions. Fortunately, one piece of test equipment has been developed, which is commercially available, the RPA 2000 (Monsanto Co.), which may meet the requirements. A considerable number of investigations have been reported on the RPA 2000 [2J, that support the view that it may meet the requirements of an instrument that measures both polymer and compound processability. The work to date identifies differences in polymers and compounds. However, it is important to relate those differences to processing characteristics in the manufacturing environment. [Pg.452]

Two main approaches to combinatorial chemistry are used—parallel synthesis and split synthesis. In parallel synthesis, each compound is prepared independently. Typically, a reactant is first linked to the surface of polymer beads, which are then placed into small wells on a 96-well glass plate. Programmable robotic instruments add different sequences of building blocks to tfie different wells, thereby making 96 different products. When the reaction sequences are complete, the polymer beads are washed and their products are released. [Pg.586]

The capacity of polymer for highly-elastic (reversible) deformations also controls, in large part, the pressure loss effect at the inlet of the forming or measuring instrument. The inlet zone length (1) is related with the highly-elastic reversible deformation SR by the formula [192] ... [Pg.28]


See other pages where Polymers instrumentation is mentioned: [Pg.59]    [Pg.17]    [Pg.187]    [Pg.59]    [Pg.17]    [Pg.187]    [Pg.1385]    [Pg.12]    [Pg.33]    [Pg.235]    [Pg.198]    [Pg.63]    [Pg.87]    [Pg.114]    [Pg.486]    [Pg.522]    [Pg.524]    [Pg.552]    [Pg.25]    [Pg.242]    [Pg.330]    [Pg.193]    [Pg.209]    [Pg.1141]    [Pg.361]    [Pg.349]    [Pg.536]    [Pg.588]    [Pg.5]    [Pg.273]    [Pg.569]    [Pg.441]    [Pg.66]    [Pg.302]    [Pg.50]    [Pg.143]    [Pg.79]    [Pg.5]    [Pg.3]   
See also in sourсe #XX -- [ Pg.300 ]