Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Polymeric permeability

A planar, polymeric, permeable textile (geosynthetic) used for geotechnical engineering purposes. [Pg.465]

Polymeric vinylidene chloride generally produced by free radical polymerization of CH2 = CCl2. Homopolymers and copolymers are used. A thermoplastic used in moulding, coatings and fibres. The polymers have high thermal stability and low permeability to gases, and are self extinguishing. [Pg.421]

Ion-exchange methods are based essentially on a reversible exchange of ions between an external liquid phase and an ionic solid phase. The solid phase consists of a polymeric matrix, insoluble, but permeable, which contains fixed charge groups and mobile counter ions of opposite charge. These counter ions can be exchanged for other ions in the external liquid phase. Enrichment of one or several of the components is obtained if selective exchange forces are operative. The method is limited to substances at least partially in ionized form. [Pg.1109]

We consider this system in an osmotic pressure experiment based on a membrane which is permeable to all components except the polymeric ion P that is, solvent molecules, M" , and X can pass through the membrane freely to establish the osmotic equilibrium, and only the polymer is restrained. It does not matter whether pure solvent or a salt solution is introduced across the membrane from the polymer solution or whether the latter initially contains salt or not. At equilibrium both sides of the osmometer contain solvent, M , and X in such proportions as to satisfy the constaints imposed by electroneutrality and equilibrium conditions. [Pg.569]

Membranes made by interfacial polymerization have a dense, highly cross-linked interfacial polymer layer formed on the surface of the support membrane at the interface of the two solutions. A less cross-linked, more permeable hydrogel layer forms under this surface layer and fills the pores of the support membrane. Because the dense cross-linked polymer layer can only form at the interface, it is extremely thin, on the order of 0.1 p.m or less, and the permeation flux is high. Because the polymer is highly cross-linked, its selectivity is also high. The first reverse osmosis membranes made this way were 5—10 times less salt-permeable than the best membranes with comparable water fluxes made by other techniques. [Pg.68]

Copolymers of diallyl itaconate [2767-99-9] with AJ-vinylpyrrolidinone and styrene have been proposed as oxygen-permeable contact lenses (qv) (77). Reactivity ratios have been studied ia the copolymerization of diallyl tartrate (78). A lens of a high refractive iadex n- = 1.63) and a heat distortion above 280°C has been reported for diallyl 2,6-naphthalene dicarboxylate [51223-57-5] (79). Diallyl chlorendate [3232-62-0] polymerized ia the presence of di-/-butyl peroxide gives a lens with a refractive iadex of n = 1.57 (80). Hardness as high as Rockwell 150 is obtained by polymerization of triaHyl trimeUitate [2694-54-4] initiated by benzoyl peroxide (81). [Pg.87]

Cast molding is an increasingly used manufacturing process for both rigid gas-permeable and hydrogel contact lenses. In this process, two molds, made from a variety of plastics, are used. A female mold forms the lens front surface (convex) and a male mold forms the lens back surface (concave). The plastic molds are made from metal tools or dies that are usually stainless steel, precision lathed, and polished to the specified lens design. A variety of mold materials are used. The polymerized, hardened lens is released from the mated molds and is processed in much the same way as the spin-cast lenses described above. [Pg.107]

The materizils in current use have limited resistance to the broad ranges of commonly spilled chemicetl solvents. In fact, no one suit material is known to resist attack by all chemicals. Rubber or polymeric materials eire all permeable to some degree but for some chemicals, there is no acceptable gairment available to provide adequate protection for the wearer. Consequently chemiczil response teams must rely on an inventory of suits constructed of different materials to provide adequate personnel protection. [Pg.6]

In Sec. 3 our presentation is focused on the most important results obtained by different authors in the framework of the rephca Ornstein-Zernike (ROZ) integral equations and by simulations of simple fluids in microporous matrices. For illustrative purposes, we discuss some original results obtained recently in our laboratory. Those allow us to show the application of the ROZ equations to the structure and thermodynamics of fluids adsorbed in disordered porous media. In particular, we present a solution of the ROZ equations for a hard sphere mixture that is highly asymmetric by size, adsorbed in a matrix of hard spheres. This example is relevant in describing the structure of colloidal dispersions in a disordered microporous medium. On the other hand, we present some of the results for the adsorption of a hard sphere fluid in a disordered medium of spherical permeable membranes. The theory developed for the description of this model agrees well with computer simulation data. Finally, in this section we demonstrate the applications of the ROZ theory and present simulation data for adsorption of a hard sphere fluid in a matrix of short chain molecules. This example serves to show the relevance of the theory of Wertheim to chemical association for a set of problems focused on adsorption of fluids and mixtures in disordered microporous matrices prepared by polymerization of species. [Pg.294]

The sizes and concentration of the free-volume cells in a polyimide film can be measured by PALS. The positrons injected into polymeric material combine with electrons to form positroniums. The lifetime (nanoseconds) of the trapped positronium in the film is related to the free-volume radius (few angstroms) and the free-volume fraction in the polyimide can be calculated.136 This technique allows a calculation of the dielectric constant in good agreement with the experimental value.137 An interesting correlation was found between the lifetime of the positronium and the diffusion coefficient of gas in polyimide.138,139 High permeabilities are associated with high intensities and long lifetime for positron annihilation. [Pg.300]

Water Permeation and Solute Separation through the Membrane. The measurements of water permeability of the 67 membranes prepared under different conditions were carried out by using an Amicon Diaflo Cell (effective membrane area, 13.9 cm2) under a pressure of 3 kg/cm2 at 25 °C. Some results are listed in Table 1067. It is apparent that much higher water absorption and permeability than the cellulosic membrane are characteristic of the 67 membranes prepared by both the casting polymerization and conventional casting. [Pg.79]

The permeability tests for alkali metal ions in the aqueous solution were also conducted. When an aqueous salt solution moves to cell 2 through the membrane from cell 1, the apparent diffusion coefficient of the salt D can be deduced from a relationship among the cell volumes Vj and V2, the solution concentration cx and c2, the thickness of membrane, and time t6 . In Table 12, permeabilities of potassium chloride and sodium chloride through the 67 membrane prepared by the casting polymerization technique from the monomer solution in THF or DMSO are compared with each other and with that the permeability through Visking dialyzer tubing. The... [Pg.80]

The polymeric products from disordered AG have much smaller molecular weights and reduced tendency to self-associate in solution. Such properties may be desirable in applications requiring membrane permeability. [Pg.49]

The hydrophilic/hydrophobic SIN composition of PDMS with poly(HEMA) and poly(AAC) were proposed as a potential apphcation for high-permeability soft contact lenses. Other sUicone-containing IPNs for contact lenses include polymerization of MMA in the presence of polymerized methacryloxypropyl trimethoxysilane, the cross-linking of a polymeric hydrogel of a copolymer of NVP during the final compression or injection-moulding process. [Pg.246]

This review of PCL and its copolymers is largely drawn from the nonpatent literature and focuses primarily on aspects relevant to drug delivery. Methods of polymerization are considered at some length because of the impact on polymer structure and morphology, which in turn determine the permeability and biodegradability of the product. [Pg.72]


See other pages where Polymeric permeability is mentioned: [Pg.29]    [Pg.144]    [Pg.232]    [Pg.330]    [Pg.527]    [Pg.152]    [Pg.2228]    [Pg.447]    [Pg.358]    [Pg.778]    [Pg.163]    [Pg.253]    [Pg.134]    [Pg.323]    [Pg.511]    [Pg.186]    [Pg.423]    [Pg.556]    [Pg.7]    [Pg.240]    [Pg.188]    [Pg.33]    [Pg.51]    [Pg.73]    [Pg.75]    [Pg.243]    [Pg.798]    [Pg.435]    [Pg.516]    [Pg.660]    [Pg.308]    [Pg.200]    [Pg.331]    [Pg.171]    [Pg.229]   
See also in sourсe #XX -- [ Pg.85 ]




SEARCH



© 2024 chempedia.info