Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Phase analyzer

Finally, and as important as all of the features of this method, the sample can be re-equilibrated with successive fresh volumes of gas and each successive phase analyzed. The result of these series of analyses will be to define the distribution of the particular compound or compounds involved, thereby providing a measure of another physical property of the compound involved. This amounts to a qualitative mechanism of identification of trace components as a part of the primary analysis. It also provides for an extrapolation of this accumulated data to a zero equilibration stage which would be indicative of the original concentration, even though the process of taking and transporting... [Pg.405]

VOC emission rate (pglr1) determined from the pre-operating phase Analyzed mass (pg) of VOC during the printing phase and post-operating phases... [Pg.412]

The response of the system to SO is linear at him levels (ca. > 1 ppbv) but nonlinear at lower levels. This is a characteristic of the reaction system since the same behavior is exhibited by the liquid phase analysis system. Figure 7 shows this nonlinearity at low SO2 levels for the gas phase analyzer. A second-degree equation (e.g., for the data shown, Y = aX2+bX+c produces excellent fit, correlation coefficient > 0-999) and may be used for calculations. It should be noted that both the measures suggested above for improving the LOD actually result in an increase of the analyte concentration and thus do not involve an increased need for manipulation in the nonlinear response region. [Pg.391]

Direct methods Aim for no negative areas in electron-density map. Probabilities of phases analyzed. Used for small molecules. [Pg.332]

Fig. 8 a Experimental setup to perform impedance analysis of the shear oscillation. Quartz resonators are used as the bottom plate of a measuring chamber that is mounted in a temperature-controlled Faraday cage. Impedance data is recorded with a gain/phase analyzer in the vicinity of the fundamental resonance of 5 MHz (typically from 4.97 MHz to 5.04 MHz). b Butterworth-Van Dyke equivalent circuit to analyze the impedance raw data of the loaded resonator. All parameters except Zl are assigned to the unperturbed resonator whereas Zl denotes the impedance of the load material (cell layer) on the resonator surface... [Pg.318]

Solartron. (2005). 1260 Impedance/gain-phase Analyzer. Operating Manual. [Pg.100]

Enzymatic reaction can be used for the analysis of not only organic phosphorous chemical agents, but also organic phosphorous pesticides and carbamates, as these compounds also inhibit cholinesterase, and can occur together with CWA in field conditions. Therefore, methods have been developed for differentiating cholinesteraseblocking pesticides and organic phosphorous CWA. Ten insecticides and soman and VX were separated on a plate with silica gel. A mixture of dichloroethane and ethyl acetate (9 1) was used as the mobile phase. Analyzed chemicals were identified with selective reactions. Total time of the analysis did not exceed 30 min. [Pg.404]

Surfactants are unique substances made up of two entities or moieties of completely different nature in the same molecule. Because of the fact that the two opposing moieties of the same molecule enable the surfactants to reorient themselves at the interface of completely different surfaces, the surfactants remain active at the interfaces involving substances of different phases as well as of similar phases. Analyzed at the macrolevel, all systems (natural or human-made) can easily be categorized into two major groups, based on their polarity, as polar (water-soluble or water loving) and nonpolar (oil-soluble or oil loving or water-hating). [Pg.420]

K after 1215 min. The apparatus was cooled to room temperature, and the headspace gases and liquid phase analyzed by GC, giving the results shown in Table 15.1. Gas-phase products were identified by comparison of their retention time with authentic samples. Liquid-phase products were identified by retention time comparison and GC-MS. The recovered liquid phase was pale blue-green with most of the metal collected in a sticky mass. [Pg.434]

Agilent HP 4194A lOHz OMHz discontinued) Impedance/gain-phase analyzer... [Pg.596]

The flat surfaces of the samples were potished, cleaned and coated with silver electrode to get a better Ohmic contact for electric properties measurement. There are total five different electrode size used for electrode size study, as tist in Table-1. After electrode coating, the samples were poled under 3.0 kV/mm electric field at elevated temperature lOO C for Ih in the silicone oil bath. After polarization, the piezoelectric properties were surveyed with an HP4194A Impedance/ Gain-Phase Analyzer and Berlincourt ds3 meter based on the IEEE standards [IEEE, 1987]. Resonant spectrum of the samples was determined in the frequency range from 100 kHz to 1500 kHz, and the results were recorded by a PC base data acquisition system. [Pg.31]

Execution Unit Organization Analysis This phase analyzes the behavior and calculates various parameters such as data width, address width, external data bus width and external address bus width. The relationship between these parameters is used to determine how the execution unit should be organized. Execution unit organization analysis is described in Section 7.3. In contrast, EMUCS does not perform a similar analysis. This task is necessarily specific to the microprocessor because in the general case, separate address and data sections cannot be assumed. [Pg.160]

Expression Context Analysis This phase analyzes each expression in the behavior and determines how it is used in relation to the expressions surrounding it. For instance, the result of an expression may be used only as a memory address. This information is recorded and used later by a synthesis phase to assign an appropriate type of register to the expression. As for Execution Unit Organization Analysis, this phase is specific to microprocessor design. [Pg.160]

Drug Classes Sample Pretreatment Type (Volume) Cartridge Type Chromatographic Column Mobile Phase Analyzer (hiterface) Acquisition Mode Rec. (%) LOD (ng/L) Reference... [Pg.119]

Chlortetracycline peak, tube 52 AT = 1.11 Oxytetracycline peak, tube 30 Af = 0.435 Phases analyzed by assaying against Bacillus megatherium Ref. [Pg.377]

The copolymers were characterized by D, TGA, X-ray and impedance gain-phase analyzer. The results and discussion was specified as follows ... [Pg.368]

In the following discussion the X-ray diffraction (XRD) patterns of a series of six industrial catalysts are compared. High-resolution scans were obtained with monochromated Co radiation on a transmission Guinier diffractometer. Phase analyses were carried out on an automated Phillips APD 10 powder diffractometer using postmonochromated Cu radiation. In Fig. 2.2, relevant sections of the diffraction patterns of catalysts from three industrial sources are displayed. The observed reflections can be assigned to magnetite and wustite as the main components of the catalysts. The catalysts differ markedly in their content of crystalline wustite. It should be stressed here that XRD is not a suitable method for quantitative determination of the wustite content, since it depends on the crystallinity of the phase analyzed. The nonstoichiometric nature of wustite and its close structural... [Pg.23]

The MS-Nose consists of an atmospheric pressure chemical ionization gas phase analyzer (APCI-GPA) attached to a VG Quattro II MS mass spectrometer [5] the cone voltage was 20 V. The ions monitored (MH+, M H2O + H+) were 58 (acetone in the panelists breath), 71 (amyl acetate fragment), 83 (cit-3-hexenol), 117 (ethyl butyrate), 131 (amyl acetate), 137 (linalool), and 163 (methyl cinnamate). [Pg.121]

Figure 2.4. Schematic of a droplet with two separate phases, surface excess charge and internal electrically neutral. Analytes (A and B ) compete with electrolyte (E ) for the surface excess charge phase of the droplet. A postulate of the equilibrium partitioning model is that the analytes that are part of the surface excess charge phase are most likely to become gas-phase (analyzable) ions. Those ions that reside in the droplet interior will be paired with counterions and consequently will not be detectable by the mass spectrometer. (Reprinted fiom Ref. 77, with permission.)... Figure 2.4. Schematic of a droplet with two separate phases, surface excess charge and internal electrically neutral. Analytes (A and B ) compete with electrolyte (E ) for the surface excess charge phase of the droplet. A postulate of the equilibrium partitioning model is that the analytes that are part of the surface excess charge phase are most likely to become gas-phase (analyzable) ions. Those ions that reside in the droplet interior will be paired with counterions and consequently will not be detectable by the mass spectrometer. (Reprinted fiom Ref. 77, with permission.)...

See other pages where Phase analyzer is mentioned: [Pg.618]    [Pg.265]    [Pg.124]    [Pg.90]    [Pg.291]    [Pg.285]    [Pg.391]    [Pg.11]    [Pg.40]    [Pg.367]    [Pg.60]    [Pg.43]    [Pg.117]    [Pg.38]    [Pg.22]    [Pg.569]    [Pg.62]    [Pg.202]    [Pg.5835]    [Pg.52]    [Pg.975]    [Pg.132]    [Pg.192]    [Pg.288]    [Pg.522]    [Pg.447]    [Pg.548]    [Pg.54]    [Pg.109]    [Pg.686]    [Pg.1]   
See also in sourсe #XX -- [ Pg.642 ]




SEARCH



Gas-phase electrophoretic mobility molecular analyzer

Phase-Doppler particle analyzer

Phased air-based analyzer

Poly PHASED analyzer

Skill 15.5 Analyzing vapor pressure curves and phase diagrams

© 2024 chempedia.info